Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 02 2019
Journal Name
Journal Of The College Of Languages (jcl)
A Pragmatic Analysis of the Use of Intensifiers in Charles Dickens’ Hard Times
...Show More Authors

The present study investigates the use of intensifiers as linguisticdevices employed by Charles Dickens in Hard Times. For ease of analysis, the data are obtained by a rigorous observation of spontaneously occurring intensifiers in the text. The study aims at exploring the pragmatic functions and aesthetic impact of using intensifiers in Hard Times.The current study is mainly descriptive analytical and is based on analyzing and interpreting the use of intensifiers in terms ofHolmes (1984) andCacchiani’smodel (2009). From the findings, the novelist overuses intensifiers to the extent that 280 intensifiers are used in the text. These intensifiers(218) are undistinguished

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Iraqi Journal Of Physics
Effect of Carbon Nanoparticles on the Performance Efficiency of a Solar Water Heater
...Show More Authors

Carbon nanoparticles are prepared by sonication using carbon black powder. The surface morphology of carbon black (CB) and carbon nanoparticles (CNPs) is investigated using scanning electron microscopy (SEM). The particles size ranges from 100 nm to 400 nm for CB and from 10 nm to 100 nm for CNPs. CNPs and CB are mixed with silicon glue of different ratios of 0.025, 0.2, 0.05, and 0.1 to synthesis films. The optical properties of the prepared films are investigated through reflectance and absorbance analyses. The ratio of 0.05 for CNPs and CB is the best for solar paint because of its higher solar water heater efficiency and is then added to the silicon glue . Temperature of cold water and temperature of hot water in storage tank were ta

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 01 2016
Journal Name
American Journal Of Dentistry
Effect of adhesive materials on shear bond strength of a mineral trioxide aggregate
...Show More Authors

Preview PDF
Scopus (6)
Scopus
Publication Date
Thu Sep 03 2020
Journal Name
Al-kindy College Medical Journal
Unusual Location of Giant Cell Tumor of the Tendon Sheath .. A Case Report
...Show More Authors

Locking of the knee is a one of the commonest orthopedic outpatient presentation. This patient usually need magnetic resonance imaging (MRI) when there is suspected lesion in the soft tissue clinically. Meniscal tears is the first differential diagnosis when accompany with painful knee. (1, 2)Giant cell tumor (GCT) is benign a localized nodular tenosynovitis often occur in the tendon sheath , Mostly involve the hand tendons in middle age group between 30 and 50 years old , female affect more than male.(3,4) The WHO defines two well-known kinds of giant cell tumor: (1) pigmented villonodular synovitis ( generalized type), which mainly involve the joints of the lower limb and (2) giant cell tumor of the tendon sheath ( localized type)

... Show More
Preview PDF
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of The College Of Languages (jcl)
A Multimodal Analysis of Hyperbolic Devices in Advertisements of Health and Beauty Products
...Show More Authors

         This paper examines the use of one of the most common linguistic devices which is hyperbole. It shows how hyperbolic devices are used as an aspect of exaggeration or overstatement for an extra effect in which the speaker can use hyperbole to add something extra to a situation in order to exaggerate his idea or speech. It is, like other figures of speech, used to express a negative or positive attitude of a specific unit of language. Thus, this paper is set against a background of using hyperbole concerning two main fields (advertisements and propaganda). So, the use of hyperbole will be implied by analyzing them concerning their meaning) literal and non-literal).  Methodology of this

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 17 2023
Journal Name
Journal Of Engineering
A Simulation of Core Displacement Experiments for the Determination of the Relative Permeability
...Show More Authors

Computations of the relative permeability curves were made through their representation by two functions for wetting and nonwetting phases. Each function contains one parameter that controls the shape of the relative permeability curves. The values of these parameters are chosen to minimize an objective function, that is represented as a weighted sum of the squared differences between experimentally measured data and the corresponding data calculated by a mathematical model simulating the experiment. These data comprise the pressure drop across core samples and the recovery response of the displacing phase. Two mathematical models are constructed in this study to simulate incompressible, one-dimensional, two-phase flow. The first model d

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF
Publication Date
Tue Sep 29 2020
Journal Name
International Journal Of Innovation, Creativity And Change
A Pragma-Linguistic Study of Deontic Modals in the Language of International Contracts.
...Show More Authors

Deontic modality expresses what is necessary or possible according to the norms of morality and laws of community. It is a cover term for those cases where modal auxiliaries used to express notions like ''obligation'', ''prohibition'' and, ''permission''. Deontic modals are basically performatives, having the ''so-be-it'' component of directives in that the speaker directs the behavior of the addressee to get things done. The present study identifies the use of deontic models in international contracts to prove that there are major pragmatic strategies employed in writing them. To achieve the aim of the study, a modified model of Danet’s (1980) and Trosborg’s (1995) in accordance to Searle (1969) is used to analyze 16 texts selected fro

... Show More
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
A comparative anatomic study of leaves of the genus Stachys L. in Iraq
...Show More Authors

The anatomic characteristics of the leaves of 22 taxa of Stachys L. representing seven of the currently recognized sections distributed in northern Iraq, were examined. The study did not found any variations in the characteristics of the stomata system of the leaves.Therewere variations with a good taxonomic value in other anatomic characteristics.Thevariations in characters of the mesophyll tissue in S.kurdica var.brevidens Bom ex Bhattacharjeewas bifacial but in S.kurdica var.kurdica Boiss. & Hohen.was unifacial .The study also found that the taxa S.benthamiana Bioss., S.lanigera (Bornm.) Rech.f. andS.kotscyi Bioss. with 3 vascular bundles in the middle vein while the taxa S.ballotiformis Vatke., S.megalodonta Hausskn. &Bo

... Show More
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Applied Sciences And Nanotechnology
Characterization of Prepared Polyaniline Nanofibers Based on a Hydrothermal Variation of Aniline Concentration
...Show More Authors

Polyaniline nanofibers (PAni-NFs) have been synthesized under various concentrations (0.12, 0.16, and 0.2 g/l) of aniline and different times (2h and 3 h) by hydrothermal method at 90°C. Was conducted with the use of X-ray diffraction (XRD), Fourier Transform Infrared spectra (FTIR), Ultraviolet-Visible (UV-VIS) absorption spectra, Thermogravimetric Analysis (TGA), and Field Emission-Scanning Electron Microscopy (FE-SEM). The X-ray diffraction patterns revealed the amorphous nature of all the produced samples. FE-SEM demonstrated that Polyaniline has a nanofiber-like structure. The observed typical peaks of PAni were (1580, 1300-1240, and 821 cm-1 ), analyzed by the chemical bonding of the formed PAni through FTIR spectroscopy. Also, tests

... Show More
View Publication
Crossref (2)
Crossref