Preferred Language
Articles
/
jkmc-797
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up: Utility of Immediate Post Placental Insertion of Intrauterine Device During Cesarean Delivery
...Show More Authors

Background: Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq.

Objectives: To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women.

Subjects and Methods: A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years.

Results:  Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and ‎heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the ‎frequency of complaints (P= 0.002).  Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes ‎mellitus. Diabetes was ‎a significant predictor for immediate post-partum intrauterine device removal, P= 0.049.

Conclusion: The intrauterine device placement during cesarean delivery with suture fixation is a safe procedure with a zero-expulsion rate and is an effective reversible long-term contraceptive method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
Charge density distributions for odd-A of 2s-1d shell nuclei
...Show More Authors

An analytical expression for the charge density distributions is derived based on the use of occupation numbers of the states and the single particle wave functions of the harmonic oscillator potential with size parameters chosen to reproduce the observed root mean square charge radii for all considered nuclei. The derived expression, which is applicable throughout the whole region of shell nuclei, has been employed in the calculations concerning the charge density distributions for odd- of shell nuclei, such as and nuclei. It is found that introducing an additional parameters, namely and which reflect the difference of the occupation numbers of the states from the prediction of the simple shell model leads to obtain a remarkabl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
Analytical study of the high absorption Region of the optical absorption edge of a-Si:H films using the derivative method
...Show More Authors

In this research, optical absorption data (the imaginary part of the dielectric function Ɛ2 as a function of photon energy E) were re-analyzed for three samples of a-Si:H thin films using derivative methods trying to investigate the ambiguity that accompany the interpretation of the optical data of these film in order to obtainm the optical energy gap (Eg) and the factor (r) which in concerned with the density of state distribution near the mobility edge directly without the need for a pre- assumption for the factor r usually followed in traditional methods such as the Tauc plot. The derivative method was used for two choices for the factor q (which in connected with the dependence of the dipole matrix element on the photon energy ) for

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 09 2019
Journal Name
Al-kindy College Medical Journal
The Prevalence of Acetabular Retroversion among Adult Patients Presenting with Hip Pain in Orthopedic Clinic of Al-Kindy Teaching Hospital
...Show More Authors

Background: Acetabular retroversion has been proposed to contribute to the development of pain and osteoarthritis of the hip. Conventional anteroposterir (AP) pelvic radiographs may represent a reliable, easily available diagnostic modality.

Objective: To obtained a reproducible technique allowing the anterior and posterior acetabular rims to be visible for assessment

Method: This is a cross-sectional study conducted from December 2015 to March 2017 targeting patients with hip pain in orthopedic clinic of Al-Kindy teaching hospital. The study sample consisted of 100 patients with hip pain who were investigated with Antroposterior pelvic plain x-ray, which was done for all

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 12 2018
Journal Name
International Journal Of Medical Research & Health Sciences
A Comparison of Fear Levels of Endodontic Treatment in Iraqi Population
...Show More Authors

Introduction: Dental fear is defined as the patient’s specific reaction towards stress related to dental treatment in which the stimulus is unkn..

View Publication Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
2019 Ieee Asia-pacific Conference On Computer Science And Data Engineering (csde)
Effect of Clay Content on Performance of a Crushed Rock Mix
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Mar 05 2024
Journal Name
Journal Of Biotechnology Research Center,
A review of the Prevalence of Enterohemorrhagic E. coli in Iraq
...Show More Authors

Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
A study of the characterization of CdS/PMMA nanocomposite thin film
...Show More Authors

Nanocomposites of polymer material based on CdS as filler
material and poly methyl methacrylate (PMMA) as host matrix have
been fabricated by chemical spray pyrolysis method on glass
substrate. CdS particles synthesized by co-precipitation route using
cadimium chloride and thioacetamide as starting materials and
ammonium hydroxide as precipitating agent. The structure is
examined by X-ray diffraction (XRD), the resultant film has
amorphous structure. The optical energy gap is found to be (4.5,
4.06) eV before and after CdS addition, respectively. Electrical
activation energy for CdS/PMMA has two regions with values of
0.079 and 0.433 eV.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Baghdad Science Journal
Properties of the Adjoint Operator of a General Fuzzy Bounded Operator
...Show More Authors

Our goal in the present paper is to recall the concept of general fuzzy normed space and its basic properties in order to define the adjoint operator of a general fuzzy bounded operator from a general fuzzy normed space V into another general fuzzy normed space U. After that basic properties of the adjoint operator were proved then the definition of fuzzy reflexive general fuzzy normed space was introduced in order to prove that every finite dimensional general fuzzy normed space is fuzzy reflexive.

View Publication
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Int. J. Nanoelectronics And Materials
The response of a window glass to the frequencies of sound
...Show More Authors

Preview PDF
Publication Date
Sat Feb 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the esthetic smile in a sample of Iraqi population
...Show More Authors

Background: The aim of the present study is to evaluate the esthetic smile in sample of Iraqi adults and to assess the gender differences. Materials and Methods: 100 persons (50malesand 50 females had class I normal dental and skeletal selected for this study.Clinical examination and digital photograph with posed smile were performed for each individual. Six linear soft tissue parameters in each photograph using AutoCAD program 2011. Five visual and four quantitative evaluations of the smile were studied for eachsubject. The smile arch and index, buccal corridor spaces (BCSs) were studied.Descriptive statistics of the measurements were calculated. Independent student’s ttestswere used to evaluate the gender differences. Statistics: Desc

... Show More
View Publication Preview PDF