|
Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice. Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospital in Baghdad, Iraq from the 1st of August to the 30th of October 2018. Transcutaneous bilirubin measurement on forehead and upper sternum was done by JM 103 Minolta Air shields bilirubinometer. Total serum bilirubin was measured by APEL BR 501 BILIRUBIN METER. Data entered & analyzed using SPSS 20 computer software. Means, frequencies, cutoff values, sensitivity & specificity were calculated. Results: The mean age, gestational age & birth weight were (6.3±4.3 days), (36.9±2.1 weeks) and (2.7±0.6 Kg) respectively. Mean total serum bilirubin, transcutaneous chest & forehead bilirubin levels were 12.6±4.2 mg/dl, 11.8±3.8 mg/dl & 11.2±3.9 mg/dl respectively. Mean total serum bilirubin was significantly higher than transcutaneous chest and forehead bilirubin. Cutoff values of transcutaneous chest & forehead bilirubin levels were [(9 mg/dl) with sensitivity (95.4%) & specificity (86.4%)] and [(8.2 mg/dl) with sensitivity (94.7%) & specificity (86.4%)] respectively. |
Ameloblastic fibroma is a rare benign tumor usually affects the first two decades of life. The neoplasm is more predominant in mandibular molar-premolar region and rarely affects the maxilla. In this report, we present a couple of Ameloblastic fibroma cases, affecting boys at their 1st decade. The lesions were presented as swellings of their maxilla, which is atypical location. Radiographic images showed well-defined radiolucency containing areas of radio-opacities and impacted teeth. Differential diagnosis was established as cystic/neoplastic conditions. The lesions were incised and histopathologically diagnosed as Ameloblastic fibroma, since they were composed of immature odontogenic mesenchymal and epithelial cells showing different c
... Show MoreThe piled raft is a geotechnical composite construction consisting of three elements: piles, raft and soil.
In the design of piled rafts, the load shared between the piles and the raft, and the piles are used up to a
load level that can be of the same order of magnitude as the bearing capacity of a comparable single
pile or even greater. Therefore, the piled raft foundation allows reduction of settlements in a very
economic way as compared to traditional foundation concepts.
This paper presents experimental study to investigate the behavior of piled raft system in sandy
soil. A small scale “prototype” model was tested in a sand box with load applied to the system through
a compression machine. The settlement was
<span lang="EN-US">The use of bio-signals analysis in human-robot interaction is rapidly increasing. There is an urgent demand for it in various applications, including health care, rehabilitation, research, technology, and manufacturing. Despite several state-of-the-art bio-signals analyses in human-robot interaction (HRI) research, it is unclear which one is the best. In this paper, the following topics will be discussed: robotic systems should be given priority in the rehabilitation and aid of amputees and disabled people; second, domains of feature extraction approaches now in use, which are divided into three main sections (time, frequency, and time-frequency). The various domains will be discussed, then a discussion of e
... Show MoreThis article aims to explore the importance of estimating the a semiparametric regression function ,where we suggest a new estimator beside the other combined estimators and then we make a comparison among them by using simulation technique . Through the simulation results we find that the suggest estimator is the best with the first and second models ,wherealse for the third model we find Burman and Chaudhuri (B&C) is best.
In the last years, the self-balancing platform has become one of the most common candidates to use in many applications such as flight, biomedical fields, industry. This paper introduced the simulated model of a proposed self-balancing platform that described the self–balancing attitude in (X-axis, Y-axis, or both axis) under the influence of road disturbance. To simulate the self-balanced platform's performance during the tilt, an integration between Solidworks, Simscape, and Simulink toolboxes in MATLAB was used. The platform's dynamic model was drawn in SolidWorks and exported as a STEP file used in the Simscape Multibody environment. The system is controlled using the proportional-integral-deriva
... Show MoreThis paper deals with constructing mixed probability distribution from mixing exponential
In this work, a CW CO2 laser was used for cutting samples of the fiber-reinforced
plastics (FRP) of three different types of reinforcing material; aramide, glass and carbon.
Cutting process was investigated throughout the variation of some parameters of cutting
process and their effects on cutting quality as well as the effect of an inert gas exist in the
interaction region and finally using a mechanical chopper in order to enhance the cutting
quality. Results obtained explained the possibility to perform laser cutting with high
quality in these materials by good control of the parameters and conditions of the process.
This paper presents a fully computerized method to backup the router configuration file. The method consists of a friendly graphical interface programmed by Java programming language.
The proposed method is compared with the two existing methods, namely: TFTP server method and Copy/Paste method. The comparison reveals that the proposed method has many advantages over the existing ones. The proposed method has been implemented on Cisco routers (series 2500, 2600 and 2800).
