Background: Acute cholecystitis is common surgical
problem, which was treated previously by conservative
treatment .Later early open has been introduced as an
alternative to interval for treatment of acute cholecystitis.
Early open was found to be a safe, successful with
comparable postoperative complication rate. With the
advent of laparoscopy laparoscopic have been used for
chronic cholecystitis and became the first line of
treatment. New reports have shown that laparoscopic can
be used as an alternative to open for surgical treatment of
acute cholecystitis.
Objectives: to compare the success, safety of early
laparoscopic versus early open as a primary treatment of
acute cholecystitis.
Methods: out of 68 patients were treated for clinical
acute cholecystitis between January 2002 and February
2004 in the department of surgery, at Al – Kindy teaching
hospital. A total of 62 patients underwent early for acute
cholecystitis as soon as possible after diagnosis. The
preferred preoperative imaging technique was ultrasound.
30 (48.3%) of the operations were attempted
laparoscopically, whereas the remaining 32 patients
(51.7%) underwent initial open .
Results: The mean operative time for the open cases
was 75 minutes versus 60 minutes for the laparoscopic
group. There was no perioperative mortality in either
group. The incidence of conversion to open was 10% (3
patients). Surgical complications related to laparoscopic
and open occurred in 2 (6.6%) and 3 (9.3%) cases,
respectively. There was no difference between the open
and laparoscopic groups in regard to the major
postoperative complications.
Conclusion: The current study shows that early
(whether performed by open or laparoscopically) is a
safe and effective treatment for acute cholecystitis. Low
conversion rates can be maintained with strict guidelines
for appropriate patient selection, adequate experience,
and proper laparoscopic technique.
Background: The surgical treatment of pilonidal sinus varies from wide excision and laying the wound open or excision with primary closure or excision with the use of skin graft in some special cases.
Objectives: The objectives of this study is to determine the efficacy of treating non complicated pilonidal sinus disease with minimal excision and primary closure technique, complications and recurrence rate.
Patients and methods: This is a prospective study conducted in shahid ahmed ismaiel hospital in rania – As sulaimania IRAQ during the period from December 2013 to January 2016 and was carried on one hundred (100) consecutive patients with non complicated non recurrent pilonidal sinus patients who were treated with minimal exci
Objective(s): To find out the incidence Rate of abortions in pregnant women Admitted Maternal and pediatric Hospitals at Al-Diwaniyah City and to identify the relationship between the incidence rate of abortion and the associated risk factors that led to the occurrence of abortion.
Methodology: A descriptive study was conducted to identify the Incidence Rate of Abortions and its Associated Factors among Women at AL-Diwaniyah City’s Maternity and pediatric Hospital from 16 September 2020 to 16 March 2021 . The sample study includes (100) pregnant women with abortion out of (3800) pregnant women. The data was collected by means of a questionnaire through a personal intervie
... Show MoreMobile-based human emotion recognition is very challenging subject, most of the approaches suggested and built in this field utilized various contexts that can be derived from the external sensors and the smartphone, but these approaches suffer from different obstacles and challenges. The proposed system integrated human speech signal and heart rate, in one system, to leverage the accuracy of the human emotion recognition. The proposed system is designed to recognize four human emotions; angry, happy, sad and normal. In this system, the smartphone is used to record user speech and send it to a server. The smartwatch, fixed on user wrist, is used to measure user heart rate while the user is speaking and send it, via Bluetooth,
... Show MoreDielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni
... Show MoreThe current study aims to apply the methods of evaluating investment decisions to extract the highest value and reduce the economic and environmental costs of the health sector according to the strategy.In order to achieve the objectives of the study, the researcher relied on the deductive approach in the theoretical aspect by collecting sources and previous studies. He also used the applied practical approach, relying on the data and reports of Amir almuminin Hospital for the period (2017-2031) for the purpose of evaluating investment decisions in the hospital. A set of conclusions, the most important of which is: The failure to apply
... Show MoreA partial temporary immunity SIR epidemic model involv nonlinear treatment rate is proposed and studied. The basic reproduction number is determined. The local and global stability of all equilibria of the model are analyzed. The conditions for occurrence of local bifurcation in the proposed epidemic model are established. Finally, numerical simulation is used to confirm our obtained analytical results and specify the control set of parameters that affect the dynamics of the model.
The fouling depositions of crude oil stream were studied theoretically in a shell and tube heat exchanger to investigate the effect of depositions on the heat transfer process. The employed heat exchanger was with steam flowing in the inner tubes and crude oil in the shell at different velocities and bulk temperatures. It is assumed that fouling occurs only on the heated stream side (crude oil). The analysis was carried out for turbulent flow heat transfer conditions with wide range of Reynolds number, bulk temperature and time. Many previously proposed models for fouling resistance were employed to estimate a new model for fouling rate. It is found that the fouling rate and consequently the heat transfer coefficient were affected by Rey
... Show MoreIn this work, 332 Al alloy was prepared and reinforced with (0.5% and 1%) nano-Al2O3 particles. The prepared unreinforced and reinforced 332 Al alloy with nano-Al2O3 were solution heat treated (T6) at 510 ̊C and aged at 225 ̊C with different times (1, 3, and 5 h). Hardness test was performed on all the prepared alloys. All prepared alloys were dry slided under different applied loads (5, 10, 15, and 20 N) against steel counterface surface using pin on disk apparatus. The results showed that refinement effect was observed after addition of nano-Al2O3 particles and a change in silicon morphology after performing the solution heat treatment. The results also showed that har
... Show MoreThe dye–semiconductor interface between N749 sensitized and zinc semiconductor (ZnSe) has been investigated and studied according to quantum transition theory with focusing on the electron transfer processes from the N749 sensitized (donor) to the ZnSe semiconductor (acceptor). The electron transfer rate constant and the orientation energy were studied and evaluated depended on the polarity of solvents according to refractive index and dielectric constant coefficient of solvents and ZnSe semiconductor. Attention focusing on the influence of orientation energies on the behavior of electron transfer rate constant. Differentdata of rate constant was discussion with orientation energy and effective driving energy for N749-ZnSe system.
... Show More