Background: Transplantation has revolutionized
treatment of end- stage renal disease (ESRD) by proving
more cost effective than hemodialysis, with a lower
morbidity and improved quality of life.
Objective: To evaluate the development of these
complications in the first month postoperatively and
correlate their development to the type of donation
whether related or unrelated.
Methods: Fifty (50) patients aged (15-62) years, with a
mean age (34.46 ± 12.4 SD) years with (ESRD), who
underwent renal transplantation from September 2000 to
October 2002, were followed-up for one month
postoperatively clinically and by assessment of renal
function tests, sonographic and Doppler examinations.
Ureteral obstruction was considered in those patients who
had allograft dysfunction, ultrasonic evidence of
peritransplant collection, moderate-severe dilatation of
upper urinary tract of transplanted kidney and
postoperative ipsilateral or bilateral leg edema. Ureteral
leakage was considered in those patients who had
persistent drainage of urine with or without allograft
dysfunction. Two patients were excluded from the followup due to death in the first 24-hour postoperatively.
Results: Six (6) patients (12.5% of cases) developed
ureteral obstruction due to peri-ureteral fluid collection. In
five patients the collection decreased and upper urinary
tract dilatation improved gradually, as shown by
ultrasound, on watchful waiting. One patient had surgical
evacuation of a large hematoma. Four (4) patients (8.3%
of cases) developed ureteral leakage. The leakage stopped
in one patient after keeping the urethral catheter for a
longer period. Three patients had surgical exploration due
to persistent urinary leakage. Redo implantation of
allograft ureter was done in two cases.
Development of ureteral complications was compared
with the type of donation (related or unrelated). The
comparison was not statistically significant.
Conclusions: The development of ureteral
complications in not related to the type of donation.
Extravesical ureteral anastamosis with the use of a stent is
less likely to be associated with postoperative ureteral
complications.
In the present study, magnet silica-coated Ag2WO4/Ag2S nanocomposites (FOSOAWAS) were fabricated via a multistep method to address the drawbacks related to single photocatalysts (pure Ag2WO4 and pure Ag2S) and to clarify the significant influence of semiconductor heterojunction on the enhancement of visible-light-driven organic degradation. Different techniques were performed to investigate the elemental composition, morphology, magnetic and photoelectrochemical properties of the fabricated FOSOAWAS photocatalyst. The FOSOAWAS photocatalyst (1 g/L) exhibited excellent photodegradation efficiency (99.5%) against Congo red dye (CR = 20 ppm) after 140 min of visible-light illumination. This result confirmed the ability of the heterojunction be
... Show Moreفي هذا البحث تم تحضير المركبات المعدنية الجديدة لأيونات البلاتين (الرباعي) و الذهب (الثلاثي) مع ليكاند قاعدة مانخ جديد مشتق من السيبروفلوكساسين . تم استخدام المعقدات بعد ذلك كمصدر لتحضير جزيئات عن طريق ترسيب المعقدات على مسام دقائق السيليكا النانوية. Si/Au2O3 Si/PtO2 تم تشخيص الليكاند و معقداته
... Show MoreA specific, sensitive and new simple method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation of ion pair compound between methyldopa and potassium hexacyanoferrate in acidic medium to obtain a yellow precipitate complex using long distance chasing photometer (NAG-ADF-300-2). The linear range for calibration graph was 0.05-35 mmol/L for cell A and 0.05-25 mmol/L for cell B, and LOD 1.4292 µg /200 µL for both cells with correlation coefficient (r) 0.9981 for cell A and 0.9994 for cell B, RSD% was lower than 0.5 % for n=8 for. The results were compared with classical method UV-Spectrophotometric at λ max=280 nm and turbi
... Show MoreBackground: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show More