Preferred Language
Articles
/
jkmc-764
Lower Ureteral Obstruction and Leakage in the First Month Following Renal Transplantation
...Show More Authors

Background: Transplantation has revolutionized
treatment of end- stage renal disease (ESRD) by proving
more cost effective than hemodialysis, with a lower
morbidity and improved quality of life.
Objective: To evaluate the development of these
complications in the first month postoperatively and
correlate their development to the type of donation
whether related or unrelated.
Methods: Fifty (50) patients aged (15-62) years, with a
mean age (34.46 ± 12.4 SD) years with (ESRD), who
underwent renal transplantation from September 2000 to
October 2002, were followed-up for one month
postoperatively clinically and by assessment of renal
function tests, sonographic and Doppler examinations.
Ureteral obstruction was considered in those patients who
had allograft dysfunction, ultrasonic evidence of
peritransplant collection, moderate-severe dilatation of
upper urinary tract of transplanted kidney and
postoperative ipsilateral or bilateral leg edema. Ureteral
leakage was considered in those patients who had
persistent drainage of urine with or without allograft
dysfunction. Two patients were excluded from the followup due to death in the first 24-hour postoperatively.
Results: Six (6) patients (12.5% of cases) developed
ureteral obstruction due to peri-ureteral fluid collection. In
five patients the collection decreased and upper urinary
tract dilatation improved gradually, as shown by
ultrasound, on watchful waiting. One patient had surgical
evacuation of a large hematoma. Four (4) patients (8.3%
of cases) developed ureteral leakage. The leakage stopped
in one patient after keeping the urethral catheter for a
longer period. Three patients had surgical exploration due
to persistent urinary leakage. Redo implantation of
allograft ureter was done in two cases.
Development of ureteral complications was compared
with the type of donation (related or unrelated). The
comparison was not statistically significant.
Conclusions: The development of ureteral
complications in not related to the type of donation.
Extravesical ureteral anastamosis with the use of a stent is
less likely to be associated with postoperative ureteral
complications.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jul 31 2012
Journal Name
Journal Of The College Of Education - University Of Tikrit
Synthesis, Spectroscopic and Biological Studies of some Metal Complexes with 1-phenyl-2(1-phenyl ethylidene) hydrozine.
...Show More Authors

Publication Date
Mon Dec 05 2016
Journal Name
Iraqi
Synthesis, spectroscopic and Antibacterial activity study of N-]2(2-phenyl hydrazinyl) phenyl benzothiazol-2-amine complexes.
...Show More Authors

Publication Date
Sun Apr 14 2019
Journal Name
International Journal Of Pharmaceutical Research
Synthesis, Characterization and Antibacterial of Some New 4,4-(pyridine-2,6-diylbis(1,3,4-oxadiazole-5,2-diyl))bisphenol Polymer
...Show More Authors

4, 4s (pyridine 2, 6 diylbis (1, 3, 4 oxadiazole 5, 2 diyl)) bisphenol monomer (3) was synthesized from cyclization of Ns2, Ns6 bis (4 hydroxybenzylidene) pyridine 2, 6 dicarbohydrazide (2) in the presence of bromine in glacialacetic acid. Newly five polymers (P1P5) were synthesized from reaction bis 1, 3, 4 oxadiazole bisphenolmonomer with five different di acid chloride. The antibacterial activity of the synthesized polymers was screened against gram positive and gram negative bacteria. Polymers P4 and P5 exhibited significant antibacterial against all microorganisms, as well these polymers showed highest antifungal activity.

Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives J.
Effect of planting distance on yield and yield components of four introduced upland rice varieties underaerobic conditions
...Show More Authors

Scopus (5)
Scopus
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Reliability Analysis of Multibit Error Correcting Coding and Comparison to Hamming Product Code for On-Chip Interconnect
...Show More Authors

Error control schemes became a necessity in network-on-chip (NoC) to improve reliability as the on-chip interconnect errors increase with the continuous shrinking of geometry. Accordingly, many researchers are trying to present multi-bit error correction coding schemes that perform a high error correction capability with the simplest design possible to minimize area and power consumption. A recent work, Multi-bit Error Correcting Coding with Reduced Link Bandwidth (MECCRLB), showed a huge reduction in area and power consumption compared to a well-known scheme, namely, Hamming product code (HPC) with Type-II HARQ. Moreover, the authors showed that the proposed scheme can correct 11 random errors which is considered a high

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 28 2016
Journal Name
Separation Science And Technology
Using sewage sludge as a permeable reactive barrier for remediation of groundwater contaminated with lead and phenol
...Show More Authors

Scopus (24)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Iraqi Journal Of Science
Determination of Optimal Temperature and pH for Radial Growth of Some Dermatophyte Species Isolated from Leukemia Patients
...Show More Authors

The study is concern on determine the effect of different temperatures (25, 28, 30 and 370C), and different pH values (4.5, 5.5, 6 and 8) on the radial growth (mm) of 15 dermatophyte isolates (Microsporum canis 7, Trichophyton rubrum 5, Trichophyton mentagropyhtes 3). The specimens for the current study were collected from nail infections in patients with different type of leukemia whom admitted at Baghdad Educational Hospital, 7th floor. The result revels that the optimum temperature for radial growth was 300C then 280C for all isolates, while the optimum pH for all isolates was 6.

Publication Date
Thu Dec 01 2022
Journal Name
Environmental Nanotechnology, Monitoring & Management
Synthesis of nano-magnetite and magnetite/synthetic geopolymer nano-porous composite for application as a novel adsorbent
...Show More Authors

In this work magnetite/geopolymer composite (MGP) were synthesized using a chemical co-precipitation technique. The synthesized materials were characterized using several techniques such as: “X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), vibrating sample-magnetometer (VSM), field-emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), Brunauer–Emmett–Teller (BET) and Barrentt-Joyner-Halenda (BJH)” to determine the structure and morphology of the obtained material. The analysis indicated that metal oxide predominantly appeared at the shape of the spinel structure of magnetite, and that the presence of nano-magnetite had a substantial impact on the surface area and pore st

... Show More
View Publication Preview PDF
Crossref (14)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
The Iraqi Journal Of Veterinary Medicine
Effect of L-Carnitine and Niacin addition on some blood parameters of fry Common Carp Cyprinus carpio
...Show More Authors

    The present study was conducted in order to focus on the effect of the addition of Carnitine and Niacin on some blood serum parameters of Common Carp Cyprinus Carpio. 48 fish carp mean weight 44.13 gm were distributed randomly on four feeding treatments (12 fish each) with replicates (6 fish each) in 8 glass aquaria. Treatments were as follows: fish were fed on basic diet without any addition and conducted as control (T1); addition of 200 mg Carnitine/ Kg diet, (T2) addition of 28 mg Niacin/Kg diet (T3), addition of a mixture of 200 mg Carnitine and 28 mg Niacin/ Kg diet as (T4). The experiment was conducted for 70 days and the results showed an increase in the Cholesterol concentration of T1 (187.6 mg/ 100 ml) and differed s

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 02 2022
Journal Name
Neuroquantology
Treatment of primary trigeminal neuralgia: A comparative study of microvascular decompression surgery and stereotactic gamma knife radiosurgery
...Show More Authors

Objectives To compare the clinical efficacy of microvascular decompression surgery (MVD) and gamma knife radiosurgery (GKR) as a treatment for patients with primary trigeminal neuralgia (TN) and evaluate the outcome regarding pain relief, recurrence, and complications with both modalities of treatment. Patients and Methods A randomized prospective study conducted in SaadAlwitry Neurosciences Hospital, Baghdad, Iraq. Eighty-four patients with TN from January 2016 to January 2018, 45 patients had GKR while 39 patients treated with MVD. The pain evaluated pre-and post-operatively using the Barrow Neurological Institute Pain Intensity scale (BNIPI), visual analog scale (VAS) and Brief Pain Inventory Facial (BPI-Facial) scoring systems. In GKR p

... Show More