Background: Dialysis is in common use to treat patients
with end stage renal failure .However longstanding dialysis
harboring some cellular changes in various body fluids.
This study was conducted in order to detect these changes
in urine.
Objective: The study was conducted to detect cellular
changes in urine of patients with longstanding dialysis.
Method: Fifty-three urine samples were examined
cytologically obtained from patients with longstanding
dialysis during 6 months period. Freshly voided midstream
urine samples were taken . Samples were centrifuged and 2
to 3 drops of sediments were smeared on 2 glass slides and
fixed in 95% ethyl alcohol then stained with Hand E stain
to be evaluated.
Results: Gross physical examination of all urine samples
were neither purulent nor hemorrhagic .Microscopically
there was increased exfoliation of urothelial cells except in
9 cases. No significant cytological atypia were seen in all
urine samples. Excessive exfoliation in the absence of
significant inflammation, hemorrhage and cytological
atypia compared with control group.
Conclusion: The study revealed that some cytological
changes do occur in the urothelial cells of patients with
longstanding dialysis. These changes need further attention
and study to disclose their causes.
Attention has recently been given to finding alternative and sustainable raw material sources for wood and metal adhesives, such as polyvinyl alcohol (PVA), corn starch (CS), arabic gum (AG), and dextrins (D). Modifying polymer dispersion using unique substances, such as modifying reactive elastomer liquid (EL) using PVA, CS, AG, or D results in sufficiently moisture-resistant adhesive joins. In the present study, the physical characteristics of EL/blended with the natural polymers PVA, CS, AG, and D, based on high-density fiberboard (HDF) wood and aluminum (Al) adhesives and coatings, were investigated and compared to those of pure EL. The EL was blended with PVA, CS, AG, or D at a ratio of 60/40 (w/w) to form EL/blends. The che
... Show MoreBackground: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth. Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this study is to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosan-collagen compared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different period of implantation time (two and six weeks) by torque removal test. Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screws coated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite by dip coating. St
... Show MoreMixed ligand metal complexes of CrIII, FeIII,II, NiII and CuII have been synthesized using 5-chlorosalicylic acid (5-CSA) as a primary ligand and L-Valine (L-Val) as secondary ligand. The metal complexes have been characterized by elemental analysis, electrical conductance, magnetic susceptibility measurements and spectral studies. The electrical conductance studies of the complexes indicate their electrolytic nature. Magnetic susceptibility measurements revealed paramagnetic nature of the all complexes. Bonding of the metal ion through –OHand –COOgroups of bidentate to the 5-chlorosalicylic acid and through –NH2 and –COOgroups of bidentate to the L-valine by FT-IR studies . The agar diffusion method has been used to study the antib
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreThe goal of this investigation is to prepare zinc oxide (ZnO) nano-thin films by pulsed laser deposition (PLD) technique through Q-switching double frequency Nd:YAG laser (532 nm) wavelength, pulse frequency 6 Hz, and 300 mJ energy under vacuum conditions (10-3 torr) at room temperature. (ZnO) nano-thin films were deposited on glass substrates with different thickness of 300, 600 and 900 nm. ZnO films, were then annealed in air at a temperature of 500 °C for one hour. The results were compared with the researchers' previous theoretical study. The XRD analysis of ZnO nano-thin films indicated a hexagonal multi-crystalline wurtzite structure with preferential growth lines (100), (002), (101) for ZnO nano-thin films with different thi
... Show MoreThis study was designed to evaluate the role of single session autologous facial fat grafting in correcting facial asymmetries after mixing it with platelet-rich fibrin (PRF) and injecting them into rich vascular facial muscular plane.
Fifteen patients (12 females and 3 males) with age ranging from 18 years to 40 years were included in this study and followed up during 6 months, all the patients were treated in the Al-Shaheed Ghazi Al-Hariri for specialized surgeries hospital (Medical City, Baghdad, Iraq).
Auto
This work is the first study of the Curculionoidea fauna from Kurdistan region of Iraq, based on the intensive survey in different localities of Kurdistan from March 2016 to November 2017. In total, 41 species belonging to 28 genera, 21 tribes and 3 families were collected and identified, including 25 species newly recorded for the Iraqi fauna.
General distribution, collecting localities and methods, with plant association data for each species are given.
Avascular necrosis have always presented great challenges to orthopedic surgeons and patients, remain in many ways today the unsolved dilemma. Varieties of non-vascularized bone grafting techniques preceded by core decompression have been proposed with varying degrees of success. O bb j ee cc t i vv ee ss : The aim of this study is to review the the value of core decompression and non-vascularized tibial bone strip graft treatment for early stages of non-traumatic osteonecrosis stage II & III according to stein burg staging . M ee t hh oo dd ss : prospectively reviewed 26 patients (32 hips) with osteonecrosis of the femoral head between June 2006 and December 2013 at Imam Ali hospital in Sader city & Al-Wasity teaching hosp
... Show MoreThe electrical insulation of the manufacture sulfonated phenol-formaldehyde viscous material (product) has been studied with Polyvinyl-acetate (PVA) and toluene diisocyanate (TDI) blend has been prepared by fixing percentage by weight 3:1 and mixed with different percentages by weight of the product sulfonated phenol formaldehyde viscous mass (SPF). The Fourier transform infrared (FTIR) spectroscopy is done on (SPF) resin powder and prepared film of PVA-TDI-SPF viscous mass. The quality factor (Q), dissipation factor (D), parallel resistance (Rp), series resistance (Rs), parallel capacitance (Cp), series capacitance (Cs) and phase shift (?) are measured. The calculated maximum dielectric constant (??) is 3.49x107 at sample (1) wt.1% SPF vis
... Show More