Background:- Cholesterol is high in ascetic fluid due
to malignancy and other causes of exudates.
Objective:-To use cholesterol as a marker to
differentiate between exudative and transudative
ascetic fluid and to compare that with other routine
parameters.
Methods:-Twenty eight patients were included in this
study 17 females with mean age of 41.9 years, 11
males with mean age of 48.2 years. The patients were
divided in group I suspected transudate, and group II
suspected exudate according to history and clinical
examination.
Ascetic fluid samples were sent for total protein,
albumin, and cholesterol measurement blood samples
were sent for serum protein and albumin measurement.
Results:-In this study ascetic fluid cholesterol was fit
with history and clinical examination to differentiate
between exudative and transudative ascetic fluid.
Cholesterol was a good marker when compared with
ascetic fluid total protein and ascetic serum protein
ratio in group I, but not in the others.
Conclusion: - cholesterol can be used as a marker for
the diagnosis of a cites cases but a large number of
patients is important for accurate results
In this paper, we study the peristaltic transport of incompressible Bingham plastic fluid in a curved channel. The formulation of the problem is presented through, the regular perturbation technique for small values of is used to find the final expression of stream function. The numerical solution of pressure rise per wave length is obtained through numerical integration because its analytical solution is impossible. Also the trapping phenomenon is analyzed. The effect of the variation of the physical parameters of the problem are discussed and illustrated graphically.
Nanotechnology has shown a lot of promise in the oil and gas sectors, including nanoparticle-based drilling fluids. This paper aims to explore and assess the influence of various nanoparticles on the performance of drilling fluids to make the drilling operation smooth, cost effective and efficient. In order to achieve this aim, we exam the effect of Multi Wall Carbon Nanotube and Silicon Oxide Nanoparticles as Nanomaterial to prepare drilling fluids samples.
Anew method for mixing of drilling fluids samples using Ultra sonic path principle will be explained. Our result was drilling fluids with nano materials have high degree of stability.
The results of using Multiwall Carbon Nanotube and Silicon Oxide show t
... Show MoreThis paper presents a study for the influence of magnetohydrodynamic (MHD) on the oscillating flows of fractional Burgers’ fluid. The fractional calculus approach in the constitutive relationship model is introduced and a fractional Burgers’ model is built. The exact solution of the oscillating motions of a fractional Burgers’ fluid due to cosine and sine oscillations of an infinite flat plate are established with the help of integral transforms (Fourier sine and Laplace transforms). The expressions for the velocity field and the resulting shear stress that have been obtained, presented under integral and series form in terms of the generalized Mittag-Leffler function, satisfy all imposed initial and boundary conditions. Finall
... Show MoreIn this paper, a numerical model for fluid-structure interaction (FSI) analysis is developed for investigating the aeroelastic response of a single wind turbine blade. The Blade Element Momentum (BEM) theory was adopted to calculate the aerodynamic forces considering the effects of wind shear and tower shadow. The wind turbine blade was modeled as a rotating cantilever beam discretized using Finite Element Method (FEM) to analyze the deformation and vibration of the blade. The aeroelastic response of the blade was obtained by coupling these aerodynamic and structural models using a coupled BEM-FEM program written in MATLAB. The governing FSI equations of motion are iteratively calculated at each time step, through exchanging data between
... Show MoreObjectives: to evaluate patient knowledge with hemodialysis and to determine the effectiveness of Self-regulation Fluid Program on Patients with hemodialysis self-efficacy for fluid adherence in Al-Diwaniyah Teaching Hospital.
Methodology: A quasi-experimental design (two group design: pre-test and post-test) was used. This study was conducted in Al-Diwaniya Teaching Hospital for the period from (15th of October 2018 to 20th of May 2019) on a non-probability (purposive) sample consisting of (60 patients) treatment in hemodialysis units. A questionnaire was built as a data collection tool and consisted of four parts:
First part: Demographic characteristics of the pati
... Show MoreThere are many configurations of directional control valve. Directional control valve has complex construction, such as moving spool to control the direction of actuator and desired speed. Magneto-rheological (MR) fluid is one of controllable fluids. Utilizing the MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This paper presents the design of multi configuration MR directional control valve. The construction and the principle of work of the valve are presented. The experiment was conducted to show the working principle of the valve functionally. The valve worked proportionally to control the direction and speed of hydra
... Show MorePurpose: To explore whether baseline matrix metalloproteinase (MMP)-8 level in gingival crevicular fluid (GCF) (exposure) can predict the outcome (reduction in probing pocket depth (PPD) (outcome)) of nonsurgical periodontal therapy (NSPT) (manual or ultrasonic or both) in patients with periodontitis (population/problem) after 3 months. Methods: Six databases (PubMed, Cochrane library, ProQuest, Ovid, Scopus, EBSCO) were searched for relevant articles published until 30 July 2021. Retrieved articles were passed through a three-phase filtration process on the basis of the eligibility criteria. The primary outcome was the change in PPD after 3 months. Quality of the selected articles was assessed using Cochrane Risk of Bias tool (RoB2
... Show MoreAn immunological technique was investigated for the detection of human semen in forensic analysis.This technique included a preparation of anti-human seminal plasma antibodies, by immunizing rabbits with treated human semen. The human semen was treated with an acid to prevent cross reactivity with other human body fluids. The antibody produced was tested against different animal,s seminal fluid samples (dog, goat ,sheep, cow) and human body fluids( saliva, blood , vaginal fluid, ear wax and human semen). It was found that using this developed technique was only selectively responsed with human semen . The prepered kit was evaluated and tested in Forensic laboratory- Ministry of Health. Finally, results were obtained in a c
... Show MoreExposure to cryogenic liquids can significantly impact the petrophysical properties of rock, affecting its density, porosity, permeability, and elastic properties. These effects can have important implications for various applications, including oil and gas production and carbon sequestration. Cryogenic liquid fracturing is a promising alternative to traditional hydraulic fracturing for exploiting unconventional oil and gas resources and geothermal energy. This technology offers several advantages over traditional hydraulic fracturing, including reduced water consumption, reduced formation damage, and a reduced risk of flow-back fluid contamination. In this study, an updated review of recent studies demonstrates how the
... Show MoreThis paper deals with modelling and control of Euler-Bernoulli smart beam interacting with a fluid medium. Several distributed piezo-patches (actuators and/or sensors) are bonded on the surface of the target beam. To model the vibrating beam properly, the effect of the piezo-patches and the hydrodynamic loads should be taken into account carefully. The partial differential equation PDE for the target oscillating beam is derived considering the piezo-actuators as input controls. Fluid forces are decomposed into two components: 1) hydrodynamic forces due to the beam oscillations, and 2) external (disturbance) hydrodynamic loads independent of beam motion. Then the PDE is discretized usi