Background: planter fasciitis is a common condition
seen in adults and sport men, it is characterized by dull
pain in the heel, especially when getting up and
standing on the foot in the morning or after sitting for a
long time.
Recently low level laser therapy is used as a method of
treatment.
Objective: to evaluate the benefit of laser therapy in
treatment of planter fasciitis.
Methods: Out of twenty five patients with planter
fasciitis exposed to laser therapy. Laser used is (diode
type) given in two cessions per week for four weeks,
time for each cession is about (12 minutes).
Results: complete recovery seen in (32%) of patients,
moderate improvement in (16%), mild improvement in
(24%), no response in (28%), deterioration (0%).
Conclusion: laser therapy is safe for treatment of
planter fasciitis, free of side effects, very effective as
an alternative to surgery and local steroid injection,
with no deterioration in the condition during or after
laser therapy
Ultraviolet light radiation is applied to treat Plaque Psoriasis disease by targeted phototherapy. This is available through Narrowband-UVB light radiation devices peaked at wavelength 311 nm. Ten cases were chosen as a study group, 8 males aged 22-40 years old, and 2 females aged 25 and 32 years old who were exposed to ultraviolet light radiation. Their recovery or improvement was followed weekly. Different doses were used according to the severity of the lesion and as a trial for the outcome. The dose was given two times a week, starting with 200mJ/cm2, and subsequently increased by 100 or 200 mJ/cm2 reaching a maximum dose as tolerated by each individual patient. Improvement was observed after 4 – 6 weeks. The
... Show MoreThe present study aimed to use the magnetic field and nanotechnology in the field of water purification, which slots offering high efficiency to the possibility of removing biological contaminants such as viruses and bacteria rather than the use of chemical and physical transactions such as chlorine and bromine, and ultraviolet light and boiling and sedimentation and distillation, ozone and others that have a direct negative impact on human safety and the environment. Where they were investigating the presence in water samples under study Coli phages using Single agar layer method and then treated samples positive for phages to three types of magnetic field fixed as follows (North Pole - South Pole - Bipolar) and compare the re
... Show MoreIn the last years, new non-invasively laser methods were used to detect breast tumors for pre- and postmenopausal females. The methods based on using laser radiation are safer than the other daily used methods for breast tumor detection like X-ray mammography, CT-scanner, and nuclear medicine.
One of these new methods is called FDPM (Frequency Domain Photon Migration). It is based on the modulation of laser beam by variable frequency sinusoidal waves. The modulated laser radiations illuminate the breast tissue and received from opposite side.
In this paper the amplitude and the phase shift of the received signal were calculated according to the orig
... Show MoreOne of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la
... Show MoreBackground: Temporomandibular joint disorders refer to a group of heterogeneous pain and dysfunction conditions involving the masticatory system, reducing life quality of the sufferers. Arthrocentesis is simple and less invasive surgical procedure for the treatment of internal derangement than arthroscopy and better than other conservative procedures such as drugs, occlusal appliances and physiotherapy. The aim of the study was to evaluate the effect of arthrocentesis with injection of hyaluronic acid in the treatment of internal derangement of temporomandibular joint for the restoration of its function, reducing pain and preventing further deterioration of the temporomandibular joint dysfunction. Materials and methods: This study was perfo
... Show MoreBackground:As arelationshipbetween gingivitis disease and the presence of the oral protozoa Trichomonastenax has been represented byconsiderable differences among various study population.The purpose of present study is determining the prevalence of T.tenax in patients with gingivitis and healthy subjects. Subjects,Materials and Methods:The presence of the parasite has been diagnosed with 58 patients withgingivitisand 58 healthy persons during the period of the study(April and May 2015) by taken two swabs for each one,microscopic examination was done using saline wet mount method and stained method. Age, sex and brushing teeth habit were in a count. Statistical analysis was done by SPSS program. Results:Gingivitis disease was observed in 5
... Show MoreKE Sharquie, SA Al-Meshhadani, AA Al-Nuaimy, Saudi medical journal, 2007 - Cited by 9
KE Sharquie, AA Noaimi, ZT Burhan, Journal of Cosmetics, Dermatological Sciences and Applications, 2016 - Cited by 9
In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance
... Show More