Back ground: Visceral leishmaniasis is endemic in the
middle and south of Iraq, it involves mostly infants. The
disease is observed mainly among rural areas that are far
from equipped medical centers. Therefore, there is a need
for anon- invasive, cost- effective, reliable, easily
available and fast method of diagnosis of this dngerous
disease.
Objective: The aim was to compare the validity and
predictive values of the recombinant K39 antigen (rK39)
test with that of the indirect fluorescent antibody test
(IFAT) test (the usual laboratory method) in the detection
of visceral leishmaniasis.
Methods: A Cross-sectional study was done in ALMansour Pediatric Hospital (in AL-Rusafa), and Central
Pediatric Hospital (in AL-Karkh) in Baghdad for 6
months duration (from the 1st of December 2004 to 30th of
May 2005). Children less than five years who suspected to
be infected with visceral leishmaniasis were selected and
investigated by IFAT test and rK39 dipstick strip.
Results: The validity of rK39 test when evaluated with
the standard methods IFAT test showed a sensitivity of
90.5%, specificity of 90.7%, predictive value positive of
77.9%, predictive value negative of 96.4% and 90.7%
accuracy.
Conclusions: The rK39 antigen strip test is valid in the
diagnosis of suspected children with visceral
leishmaniasis as the test is rapid, sensitive, and specific
Abstract
On 11/1/2008 amounts of snows fell on various sections of Iraq, one of
which is Baghdad. The analysis process of climatic maps proved that the
advance trough of Sudanese depression towards the city is the reason behind
the formation of this weather state supported by could trough in the (500) mb
pressure level. .
The research concluded that the phenomenon of global warming
witnessed by the world recently had a main role in the occurrence of this
phenomenon due to the raise in earth temperature as a result of evaporation
rate increase leading to an increase in water vapor and cloud formation with
high tops and low bases which form sows with high rates accumulating at high
and moderate latitudes le
The concentration of radon gas in the samples for drinking water and wells in the same place from selected homes in which wells were built in the Hay-al-Bayaa region of Baghdad was measured, by using a CR-39 nuclear track detector. It turns out that the maximum value of the concentration of radon in drinking water was 3.83 Bq/L, and the lowest was 2.30 Bq/L. As for the estimation of radon gas concentration in well water samples, the highest value was 5.6 Bq/L, while the lowest one was 3.1 Bq/L. In order to assess the committed effective dose received by the public due to the inhalation of radon gas. The highest value of the annual effective dose in drinking water was recorded in Al-Bayaa region, which is equal to 14.30 μSv/y, while th
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -
... Show MoreAromatic hydrocarbons present in Iraqi national surface water were believed to be raised principally from combustion of various petroleum products, industrial processes and transport output and their precipitation on surface water.
Polycyclic aromatic hydrocarbons (PAHs) were included in the priority pollutant list due to their toxic and carcinogenic nature. The concern about water contamination and the consequent human exposure have encouraged the development of new methods for
PAHs detection and removal.
PAHs, the real contaminants of petroleum matter, were detected in selected sites along Tigris River within Baghdad City in summer and winter time, using Shimadzu high performance liquid chromatography (HPLC) system.
Analysi
The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,ind
... Show MoreIn this research (100* 40* 4 cm) solar cell panel was used in Baghdad at autumn season (2010), to get best solar cell panel angles experimentally, and then a mirror (40*50 cm) is use to concentrate incident sunlight intensity on a panel. At first case we get (Tilt angle ?P =60°and Surface Azimuth angle ?P =36°E) is the best angles and other case, we add a mirror at angle = 120° at bottom of panel, then we get output power (27.48watt) is bigger than without using a mirror (25.16watt). We can benefit from these cases in variety applications.