Preferred Language
Articles
/
jkmc-73
Electrocautery versus cold steel tonsillectomy comparison study
...Show More Authors

Objective: the objective of this study was to compare the intraoperative blood loss, intraoperative time, postoperative pain and secondary hemorrhage between electrodissection and cold steel dissection tonsillectomy.

Methods: One hundred and six patients were enrolled in this study, the patients were randomly allocated into electrodissection group A (n=51) and cold steel dissection tonsillectomy group B (n=53). All patients are above 7 years and had history of recurrent tonsillitis and/or tonsillar hypertrophy with obstructive symptoms. Intraoperative parameters and postoperative outcome were assessed.

Results: In group A patients had statically significant less operative time and blood loss than group B early postoperative pain was not differ significantly between the two groups, however late onset pain (pain on the 7th day) was significantly higher in group A. There was no significant difference between the groups regarding secondary hemorrhage.

Conclusion: Electrodissection tonsillectomy is rapid, safe and effective method of tonsillectomy with obvious advantage of minimum perioperative blood loss, lower operative time and without early post-operative pain difference when compared to cold steel dissection tonsillectomy. Although it has some disadvantage of late postoperative pain.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of some robust methods to estimate parameters of partial least squares regression (PLSR)
...Show More Authors

   The technology of reducing dimensions and choosing variables are very important topics in statistical analysis to multivariate. When two or more of the predictor variables are linked in the complete or incomplete regression relationships, a problem of multicollinearity are occurred which consist of the breach of one basic assumptions of the ordinary least squares method with incorrect estimates results.

 There are several methods proposed to address this problem, including the partial least squares (PLS), used to reduce dimensional regression analysis. By using linear transformations that convert a set of variables associated with a high link to a set of new independent variables and unr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Polyvinyl Alcohol – Sodium Nitrite Water Soluble Composite as a Corrosion Inhibitor for Mild Steel in Simulated Cooling Water
...Show More Authors

The inhibitive action of polyvinyl alcohol –sodium nitrite (PVASN) composite on the corrosion of mild steel in simulated cooling water (SCW) has been investigated by weight loss and potentiodynamic polarization. The effect of composite concentration (PVA/SN) , pH, and exposure time on corrosion rate of mild steel were verified using 2 levels factorial design and surface response analysis through weight loss approach, while the electrochemical measurements were used to study the behavior of mild steel in (SCW) with pH between 6 and 8 and in absence and presence of (PVA) in solution containing different concentration of NaNO2. It was verified that all three main variables studied were statistically significant while their interaction is

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Hard Chromium Electroplating and Improvement the Properties by the Thermo Chemical Treatments (Solid Carburizing) of Low Carbon Steel
...Show More Authors

In this research the hard chromium electroplating process, which is one of the common methods of overlay coating was used, by using chromium acid as source of chromium and sulphuric acid as catalyst since the ratio between chromic acid and sulphuric acid is (100 : 1) consequently. Plating process was made by applying current of density (40 Amp / dm2) and the range of solution temperature was (50 – 55oC) with different time periods (1-5 hr). A  low carbon steel type (Ck15) was used as substrate for hard chromium electroplating. Solid carburization was carried out for hard chromium plating specimen at temperature (925oC) with time duration (2 hr) to be followed with quenching and tempering

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 07 2023
Journal Name
Innovative Infrastructure Solutions
Enhancing load-bearing performance of hybrid recycled aggregate concrete-filled columns using SBR, steel fibers and polypropylene fibers
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Infrastructures
Strength and Deformation of Concrete-Encased Grouting-Filled Steel Tubes Columns Exposed to Monotonic Quasi-Static Loading Conditions
...Show More Authors

This study aimed to evaluate the effectiveness of a novel concrete-encased column (CE) using small circular steel tubes filled with cementitious grouting material (GFST) as the primary reinforcement instead of traditional steel bars. The research involved three different types of reinforcement: conventional steel bars, concrete-filled steel tubes with 30% of the reinforcement ratio of steel bars, and concrete-filled steel tubes with the same reinforcement ratio as steel bars. Twenty-four circular concrete columns were tested and categorized into six groups based on the type of reinforcement employed. Each group comprised four columns, with one subjected to concentric axial load, two subjected to eccentric axial load (with eccentrici

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Anodic Polarization of Mild Steel in Saturated C a(OH)2 Contaminated with NaCl in Presence of NaNO2
...Show More Authors

The corrosion  behavior  of mild sleet  in saturated  aerated  and de-aerated  Ca(OH)2 solution  was  investigated  using electrochemical measurements. The work was carried out with small coupons immersed in solutions containing different quantities of NaCl in presence of various NaN02 concentrations as corrosion inhibitors. It has been found thal:(1 ) In presence  of NaCl,  the time required  to reach O2  evolution potential  in de-aerated  Ca(OH)2 polarized  at  10μA/cm 2 is function of inhibitor concentration and it becomes lass as NaN02 increases compared with zero presence indicating the effectiveness of N

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 30 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
Strengthening Aspects to Improve Serviceability of Open Web Expanded Steel-Concrete Composite Beams in Combined Bending and Torsion
...Show More Authors

View Publication
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Modelling and Optimization of Corrosion Inhibition of Mild Steel in Phosphoric Acid by Red Pomegranate Peels Aqueous Extract
...Show More Authors

Taguchi experimental design (TED) is applied to find the optimum effectiveness of aqueous Red Pomegranate Peel (RPP) extract as a green inhibitor for the corrosion of mild steel in 2M H3PO4 solution. The Taguchi methodology has been used to study the effects of changing, temperature, RPP concentration and contact period, at three levels. Weight-loss measurements were designed by construction a L9 orthogonal arrangement of experiments.   Results of the efficiencies of inhibition were embraced for the signal to noise proportion & investigation of variance (ANOVA).  The results were further processed with a MINITAB-17 software package to find the optimal condition

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro The Effect of Canals Instrumented With Three Rotary Ni-Ti Systems on The Dislocation Resistance of Guttafusion® Versus Single Cone Obturation Technique
...Show More Authors

Background: Complete seal of the root canal system following its chemo-mechanical debridement plays a pivotal role for achieving successful endodontic treatment. This can be established by reducing the gaps between the core filling material and root canal wall. Aim: To assess and compare the dislocation resistance of root canals obturated with GuttaFusion® and TotalFill BC sealer versus single cone obturation technique and TotalFill BC sealer after instrumentation of the canals with WaveOne, ProTaper Next and ProTaper Universal system. Material and Method: Sixty extracted human permanent mandibular premolars were conducted in the current study. The teeth were decorated and left the root with 15mm length; the roots were divided randoml

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 25 2019
Journal Name
International Journal Of Corrosion And Scale Inhibition
Evaluation and characterization of the symbiotic effect of benzylidene derivative with titanium dioxide nanoparticles on the inhibition of the chemical corrosion of mild steel
...Show More Authors

A new benzylidene derivative, namely N-benzylidene-5-phenyl-1,3,4-thiadiazol-2-amine (BPTA), has been synthesized and instrumentally confirmed with Elemental Analysis (CHN), Nuclear Magnetic Resonance (NMR), and Fourier Transform Infrared Spectroscopy (FT-IR). Titanium Dioxide (TiO2) nanoparticles (NPs) were synthesized and characterized by X-ray. The mutualistic complementary dependence of BPTA with TiO2 nanoparticles as anti-corrosive inhibitor on mild steel (MS) in 1.0 M hydrochloric acid has been tested at various concentrations and various temperatures. The methodological work was achieved by gravimetric measurement methods complemented with surface analysis. The synthesized inhibitor concentrations were 0.1 mM to 0.5 mM and the temper

... Show More
Preview PDF
Scopus (69)
Scopus