Background: Acute appendicitis is a common surgical
problem that is associated with an acute-phase reaction.
Previous studies have shown that cytokines and acutephase proteins are activated and may serve as indicators for
appendicitis.
Objective: The aim of this study was to evaluate of serum
levels of interleukin-6 (IL-6) in correlation to the severity
to acute appendicitis.
Methods: This is a prospective study from December 2008
to March 2009 of patients who had appendectomy in
Department of Surgery, Al-Kindy Teaching Hospital -
Baghdad/Iraq. Serum for estimating levels of interleukin-6
(IL-6) was taken pre-operatively. Depending on the
macroscopic evidence during the operation and the
histopathological examination of the specimens, the
patients were separated into 3 groups, group one with
negative appendectomy (normal appendix), group two with
non-complicated acute appendicitis (catarrhal,
suppurative), and group three with complicated acute
appendicitis (perforated, gangrenous). The
histopathological results were correlated with IL-6 values
statistically.
Results: A total number of 50 patients were included in
this study, 28 male (56%) and 22 female (44%). The mean
age was 23 year (ranged from 7 to 50). On histological
examination, there were 7 patients (14%) in group one, 29
patients (58%) in group two, and 14 patients (28%) in
group three. Serum IL-6 values gave true negative results
in 6%, true positive results in 82%, false negative results in
4%, and false positive results in 8%. We determined,
therefore, in the present study the sensitivity, specificity,
and accuracy of serum IL-6 were calculated as 95.34%,
42.85%, and 88% respectively.
Conclusion: Laboratory results should be considered to be
integrated within the clinical assessment. If used critically,
IL-6 can provide surgeons with complementary
information in discerning the necessity for urgent
operation
The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c
... Show MoreBreast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range
... Show MoreArtificial roughness applied to a Solar Air Heater (SAH) absorber plate is a popular technique for increasing its total thermal efficiency (ηt−th). In this paper, the influence of geometrical parameters of V-down ribs attached below the corrugated absorbing plate of a SAH on the ηt−th was examined. The impacts of key roughness parameters, including relative pitch p/e (6–12), relative height e/D (0.019–0.043), angles of attack α (30–75°), and Re (1000–20,000), were examined under real weather conditions. The SAH ηt−th roughened by V-down ribs was predicted using an in-house developed conjugate heat-transfer numerical model. The maximum SAH ηt−th was shown to be 78.8% as predicted under the steady-state condition
... Show MoreThe present work provides to treat real oily saline wastewater released from drilling oil sites by the use of electrocoagulation technique. Aluminum tubes were utilized as electrodes in a concentric manner to minimize the concentrations of 113400 mg TDS/L, 65623 mg TSS/L, and the ions of 477 mg HCO3/L, 102000 mg Cl/L and 5600 mg Ca/L presented in real oily wastewater under the effect of the operational parameters (the applied current and reaction time) by making use of the central composite rotatable design. The final concentrations of TDS, TSS, HCO3, Cl, and Ca that obtained were 93555 ppm (17.50%), 11011 ppm (83.22%), 189ppm (60.38%), 80000ppm (22%), and 4200 ppm (25%), respectively, under the optimum values of the operational parameters
... Show MoreOral jelly is a semisolid preparation that could resolve problem associated withdosage form’s swallowing, especially in pediatric and elderly ones. This work aimedto prepare oral flurbiprofen (FBP) jelly to improve patient compliance. Heating andcongealing method was used to prepare FBP jelly using three different polymers (pectin,sodium carboxymethyl cellulose, and hydroxypropyl methylcellulose). The effect ofdifferent concentrations of pectin and sucrose on jelly properties was studied. Theresults revealed that both pectin and sodium carboxymethyl cellulose polymers gaveacceptable jelly appearance and consistency. It was also observed that the increase ofpectin or sucrose concentration had a significant impact on jelly viscosity. All pe
... Show MoreThe main purpose of the paper is to identify the controllability of an existing production system; yogurt production line in Abu Ghraib Dairy Factory which has several machines of food processing and packing that has been studied. Through the starting of analysis, instability in production has been found in the factory. The analysis is built depending on experimental observation and data collection for different processing time of the machines, and statistical analysis has been conducted to model the production system. Arena Software is applied for simulating and analyzing the current state of the production system, and results are expanded to improve the system production and efficiency. Research method is applied to contribute in knowi
... Show MoreMobile Ad hoc Networks (MANETs) is a wireless technology that plays an important role in several modern applications which include military, civil, health and real-time applications. Providing Quality of Service (QoS) for this application with network characterized by node mobility, infrastructure-less, limitation resource is a critical issue and takes greater attention. However, transport protocols effected influential on the performance of MANET application. This study provides an analysis and evaluation of the performance for TFRC, UDP and TCP transport protocols in MANET environment. In order to achieve high accuracy results, the three transport protocols are implemented and simulated with four different network topology which are 5, 10
... Show MoreAbstract
The economic and financial crises in the world economy series led to increased awareness of the importance of the internal control system, because it is one of the main pillars of any economic unit, as it works to verify the application of policies, regulations and laws and verification of asset protection from theft and embezzlement procedures, it is also working on trust accounting information imparted through the validation of accounting information, analyze and detect the misleading.
The existence the internal control system a factor in many of the accounting practices that limit the ability of the administration to produce misleading financial reporting
The
... Show MoreBackground: Bilastine (BLA) is a second-generation H1 antihistamine used to treat allergic rhinoconjunctivitis. Because of its limited solubility, it falls under class II of the Biopharmaceutics Classification System (BSC). The solid dispersion (SD) approach significantly improves the solubility and dissolution rate of insoluble medicines. Objective: To improve BLA solubility and dissolution rate by formulating a solid dispersion in the form of effervescent granules. Methods: To create BLA SDs, polyvinylpyrrolidone (PVP K30) and poloxamer 188 (PLX188) were mixed in various ratios (1:5, 1:10, and 1:15) using the kneading technique. All formulations were evaluated based on percent yield, drug content, and saturation solubility. The fo
... Show More