Preferred Language
Articles
/
jkmc-708
MATERNAL AND FETAL OUTCOMES IN EMERGENCY VERSUS ELECTIVE TWO OR MORE PREVIOUS CAESAREAN DELIVERIES
...Show More Authors

Background: Women with previous two or
more caesarean deliveries are usually
managed by elective cesarean section to avoid
the possible risks of labor.
Objective: To compare the relative risks of
maternal and fetal outcomes in emergency
versus elective previous two or more
caesarean deliveries
Design: Randomized prospective clinical
study
Setting: Al-Elweya Maternity Teaching
Hospital, from 1st of March to 31st of
September 2008.
Methods: The study groups, those who had
previous two or more caesarean deliveries,
were included from the hospital admissions.
The 1st group (102 women) presented in labor
and was managed by caesarean delivery as
soon as it was possible. The second group (78
women) was admitted for elective cesarean
delivery.
The main maternal outcomes were intra
operative complications, including
hysterectomy, scar dehiscence, bladder
injuries, uterine and internal iliac arteries
ligation, and blood transfusion. Postoperative
maternal outcomes were severe morbidity
including bleeding, fever, urinary tract
infection, blood transfusion, the need to
Intensive Care Unit admission and
readmission. The fetal outcomes measures
were Apgar score at one and five minutes,
respiratory distress syndrome (RDS),
admission to the neonatal intensive care unit
and fetal loss up to hospital discharge.
Results: Both groups were comparable in
demographic, social and past obstetric history
characteristics. Intra operative complications
showed significant difference in bowel
adhesions (RR 0.35, 95% CI 0.14- 0.88), and
blood transfusion (RR 0.51, 95% CI 0.28-
0.94). There was statistical significant
difference in the mobilization time 7.2 hours
and 9.3 hours in emergency and elective
groups respectively (p= 0.0009), also in
feeding time, it was shorter after emergency
caesarean section (P=0.0224), and in the
hospital stay 24.6 and 32.6 hours respectively
(p=0.0001). There was no statistical difference
in post operative complications. Fetal
outcomes showed no statistical significant
difference in fetal loss, respiratory distress and
readmission.
Conclusion: Women with previous two or
more caesarean deliveries can wait until
starting labor for doing cesarean delivery
without increasing risks to the mother and
fetus.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Apr 01 2021
Journal Name
Iraqi Journal Of Applied Physics
Effects of Solvent Properties on Absorption and Fluorescence Characteristics of Two Organic Dyes Used as Random Gain Media
...Show More Authors

In this work, the effects of solvent properties on the characteristics of absorption and fluorescence for two laser dyes was studied. Dyes used in this work include Coumarin 5400 and DCM, while the solvents include ethanol, methanol, acetone, propanol and chloroform. Coumarin 5400 dye shows sharp fluorescence peaks in the green band of visible region while the DCM dye shows relatively wide band within 590-630 nm. Therefore, the selection of any dye for random gain medium applications should be performed after determining the most appropriate solvent as the optimum fluorescence characteristics are obtained.

View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Experimental and numerical investigation on the behavior of reinforced reactive powder concrete two-way slabs under static load
...Show More Authors

This paper studied the behaviour of reinforced reactive powder concrete (RPC) two-way slabs under static load. The experimental program included testing three simply supported slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. Tested specimens were of identical properties except their steel fibers volume ratio (0.5 %, 1 %, and 1.5 %). Static test results revealed that, increasing steel fibers volume ratio from 0.5% to 1% and from 1% to 1.5%, led to an increase in: first crack load by (32.2 % and 52.3 %), ultimate load by (36.1 % and 17.0 %), ultimate deflection by (33.6 % and 3.4 %), absorbed energy by (128 % and 20.2 %), and the ultimate strain by (1.1 % and 6.73 %). The stiffness and ductility of the specimens also increased. A

... Show More
View Publication
Publication Date
Fri Mar 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Robust Two-Step Estimation and Approximation Local Polynomial Kernel For Time-Varying Coefficient Model With Balance Longitudinal Data
...Show More Authors

      In this research, the nonparametric technique has been presented to estimate the time-varying coefficients functions for the longitudinal balanced data that characterized by observations obtained through (n) from the independent subjects, each one of them is measured repeatedly by group of  specific time points (m). Although the measurements are independent among the different subjects; they are mostly connected within each subject and the applied techniques is the Local Linear kernel LLPK technique. To avoid the problems of dimensionality, and thick computation, the two-steps method has been used to estimate the coefficients functions by using the two former technique. Since, the two-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2012
Journal Name
Engineering Analysis With Boundary Elements
Radial integration boundary integral and integro-differential equation methods for two-dimensional heat conduction problems with variable coefficients
...Show More Authors

View Publication
Crossref (33)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Molecular Biology Research Communications
Association study of two single nucleotide polymorphisms rs10757278 and rs1333049 with atherosclerosis, a case-control study from Iraq
...Show More Authors

View Publication
Scopus (1)
Scopus
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Clinical And Experimental Dentistry
Cusp deflection and fracture strength of root canal filled premolars with two access cavities designs (Conservative vs Traditional)
...Show More Authors

View Publication Preview PDF
Scopus (8)
Crossref (6)
Scopus Crossref
Publication Date
Tue Jun 17 2025
Journal Name
Sciences Journal Of Physical Education
Comparison of maximum strength and peak electrical activity (EMG) of the muscles of the two legs among bodybuilding players and Weightlifting
...Show More Authors

View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Dental Research Journal
Impact of a mixture of nanofiller and intrinsic pigment on tear strength and hardness of two types of maxillofacial silicone elastomers
...Show More Authors

Background: The ideal maxillofacial prosthesis should have fine and thin boundaries that bindwith the surrounding facial structures and possess high tear strength.This study aims to determinethe best percentages of nanofiller (TiO2) and intrinsic pigment (silicone functional intrinsic) thatcould be mixed in as additives to improve the tear strength of Cosmesil M511 andVST50F siliconeelastomers with the least effect on their hardness.Materials and Methods: In this in vitro experimental study, a total of 80 samples, 40 for eachelastomer, were fabricated. Each elastomer sample was split into two equal groups to test for tearstrength and Shore A hardness. Each group consisted of 20 samples, including 10 control sampleswithout additives and 10 e

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The concept of suspense and mystery with some references to dickens s Novels ; A tale of two cities and Great expectations
...Show More Authors

0

View Publication Preview PDF
Publication Date
Tue Jun 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparison between the Horizontal Condylar and Bennett Angles of Iraqi Full Mouth Rehabilitation Patients by Using Two Different Articulator Systems (An In-Vivo Study)
...Show More Authors

Background: Errors of horizontal condylar inclinations and Bennett angles had largely affected the articulation of teeth and the pathways of cusps. The aim of this study was to estimate and compare between the horizontal condylar (protrusive) angles and Bennett angles of full mouth rehabilitation patients using two different articulator systems. Materials and Methods: Protrusive angles and Bennett angles of 50 adult males and females Iraqi TMD-free full mouth rehabilitation patients were estimated by using two different articulator systems. Arbitrary hinge axis location followed by protrusive angles and Bennett angles, estimation was done by a semiadjustable articulator system. A fully adjustable articulator system was utilized to locate th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref