Background: Diabetes mellitus has been suggested
to be the most common metabolic disorder
associated with magnesium deficiency, and because
available data suggest that adverse outcomes are
associated with hypomagnesemia, it is prudent that
routine surveillance for hypomagnesemia be done
and the condition be treated whenever possible.
Aim of the study:To explore the serum Mg
concentrations of diabetic patients and healthy
controls in our locality.
Mehtods: One hundred and forty four diabetic
patients (22 with type I and 122 with type II diabetes
mellitus) recruited from the outpatient diabetes clinic
at the Specialized Center For Endocrine DiseasesBaghdad (62 patients), National Diabetes Center-Al
Mustansiria University (20 patients), and from
private endocrinologic practice clinics in Baghdad
(62 patients), during the period from 1st October
2005 to 30th April 2006. Ninety non-diabetic healthy
controls matched for age and sex were participated in
this study. Exclusion criteria for both groups
included diarrhea and loop diuretics. None were
taking Mg supplements. Level of Mg and Albumin
were determined spectrophotometerically in the
same serum samples.
Results: Mean serum Mg concentrations of the
diabetics was significantly lower than in controls
(p<0.001). Serum albumin was not a significant
predictor of serum Mg neither among diabetic
patients (r = 0.005) nor control subjects (r = 0.139).
In 88.9% of the diabetic patients and 11.1% of the
control subjects serum Mg concentrations were
below the normal reference range of 0.70 mmol/L.
The prevalence is increased when hypomagnesemia
is defined by a reference limit of 0.75 mmol/L
(98.6% and 28.9 % for diabetics and controls,
respectively), a further higher prevalence among
controls (91.1 %) was noted when 0.80 mmol/L is
adopted as the lower normal limit. All diabetics
(100%) and controls (100%) were identified as
hypomagnesemic with a lower reference limit of
0.90 mmol/L.
Conclusion: The tremendous hot climate of ours,
can be suggested as an influential cause for increased
Mg losses, and may provide a coherent explanation
for the exceedingly high prevalence of
hypomagnesemia observed in diabetic and control
subjects participated in this study. Which therefore
may suggest an inevitable requirement for
magnesium supplementation to avert
hypomagnesemia, not only among diabetics, but as
well for controls, particularly through the hot
summer episode
Background: Alginate impression material is the irreversible hydrocolloid material that is widely used in dentistry. The contact time between alginate and gypsum cast could have a detrimental effect on the properties of the gypsum cast. The objective of this study is to evaluate the impact of various contact time intervals of Alginate impressions & type III dental stone on surface properties of stone cast. Materials and Methods: Time intervals tested were 1hour, 6 hours and 9 hours. Surface properties of stone cast evaluated were surface detail reproduction, hardness and roughness. Surface detail reproduction was determined using cylindrical brass test block in accordance with ISO 1563. Surface roughness was measured by profilometer
... Show MoreHerein, we report designing a new Δ (delta‐shaped) proton sponge base of 4,12‐dihydrogen‐4,8,12‐triazatriangulene (compound
Background Fibroblast growth factor receptor 2 (FGFR2) and trinucleotide repeat-containing 9 (TNRC9) gene polymorphisms have been associated with some cancers. We aimed to assess the association of FGFR2 rs2981582 and TNRC9 rs12443621 polymorphisms with hepatocellular cancer risk. Methods One hundred patients with HCV-induced HCC, 100 patients with chronic HCV infection, and 100 controls were genotyped for FGFR2 rs2981582 and TNRC9 rs12443621 using allele-specific Real-Time PCR analysis. Results FGFR2 rs2981582 genotype TT was associated with increased risk of HCC when compared to controls (OR = 3.09, 95% CI = 1.24–7.68). However, it was significantly associated with a lower risk of HCC when using HCV patients as controls (OR =
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreIn the present study, magnet silica-coated Ag2WO4/Ag2S nanocomposites (FOSOAWAS) were fabricated via a multistep method to address the drawbacks related to single photocatalysts (pure Ag2WO4 and pure Ag2S) and to clarify the significant influence of semiconductor heterojunction on the enhancement of visible-light-driven organic degradation. Different techniques were performed to investigate the elemental composition, morphology, magnetic and photoelectrochemical properties of the fabricated FOSOAWAS photocatalyst. The FOSOAWAS photocatalyst (1 g/L) exhibited excellent photodegradation efficiency (99.5%) against Congo red dye (CR = 20 ppm) after 140 min of visible-light illumination. This result confirmed the ability of the heterojunction be
... Show More