Preferred Language
Articles
/
jkmc-691
Is co2 laser Hemorrhoidectomy superior to conventional open Hemorrhoidectomy?
...Show More Authors

Background: Hemorrhoids are one of the most
common surgical conditions .Conventional
haemorrhoidectomy was the traditional operation for
the treatment of hemorrhoids. Other modalities of
treatment had been used as an alternative operations
including CO2 laser haemorrhoidectomy.
Objectives: To determine the outcome of treatment
of hemorrhoids by using CO2 laser
haemorrhoidectomy and its advantages over
conventional surgery
Methods: This is a retrospective comparative
interventional study of 1024 case of third degree
haemorhoids selected out of 1300 case of
hemorrhoids of different degrees, admitted to
ALKINDY, ALYERMOUK teaching hospitals and
ABD ALMAGEED private hospital, from May 1998
to July 2002,they were treated by CO2 laser
haemorrhoidectomy and conventional surgery. They
are divided into 2 groups randomly, 512 cases treated
by CO2 laser (group A), 512 cases treated by
conventional surgery (group B). Both groups were
studied regarding operative time, hospital stay,
healing time, post operative complications and cost
effectiveness.
Results: In GROUP A, the operative time ranged
from 10 to 20 minutes with an average of 13 minutes.
The hospital stay ranged from 4 to 12 hours with a
mean time of 10 hours as all cases were treated as
day cases. Post operative pain was minimal in 50% of
patients and required simple analgesia for treatment
while 50% had no pain. Bleeding occurred in less
than 1% of cases, anal stenosis 3.3%, Infection
recorded in 0.58% of patients.In GROUP B, The
operative time ranged from 15 to 25 minutes with an
average time of (19) minutes, hospital stay ranged
from 24 to 48 hours with a mean time of 28 hours
.Post operative pain recorded in all the patients
(100%) and required narcotic analgesia for treatment,
25 patients (4.8%) had varying degrees of bleeding,
40 patients (7.8%) had infection, 25 patients (4.8%)
had anal stenosis.In group A due to shorter hospital
stay, earlier healing of wounds, earlier return to work
which was within 7 to 10 days, the surgical treatment
proved to be cost effective

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
A comparative study of the effects of argon laser and continuous Nd: YAG laser on blood vessel
...Show More Authors

Several types of laser are used in experimental works in order to study the effects of laser on blood vessel. They differ from each other by a lot of properties mainly in wavelength, energy of the laser and pulse duration. In this study argon laser (488 nm- 514 nm) and continuous Nd: YAG laSer (1064 nm), have been applied to 50 samples of sheep blgod tesselS. Histologically, tha results of the study were different According to the txpe of L`sar used; apgon larer had distrabtave effects on $he blood vessal while continuous Nd: YAG laser Appeaped to be the safesd one on the blmod vessel architecture. This study concluded that argoj laser has da-aging ef&ect on

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Modelling and Optimization of Carbon Steel Corrosion in CO2 Containing Oilfield Produced Water in Presence of HAc
...Show More Authors

Previously, many empirical models have been used to predict corrosion rates under different CO2 corrosion parameters conditions. Most of these models did not predict the corrosion rate exactly, besides it determined effects of variables by holding some variables constant and changing the values of other variables to obtain the regression model. As a result the experiments will be large and cost too much. In this paper response surface methodology (RSM) was proposed to optimize the experiments and reduce the experimental running. The experiments studied effects of temperature (40 – 60 °C), pH (3-5), acetic acid (HAc) concentration (1000-3000 ppm) and rotation speed (1000-1500 rpm) on CO2 corrosion performance of t

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Colloid And Interface Science
Impact of nanoparticles on the CO2-brine interfacial tension at high pressure and temperature
...Show More Authors

Hypothesis Nanofluid flooding has been identified as a promising method for enhanced oil recovery (EOR) and improved Carbon geo-sequestration (CGS). However, it is unclear how nanoparticles (NPs) influence the CO2-brine interfacial tension (γ), which is a key parameter in pore-to reservoirs-scale fluid dynamics, and consequently project success. The effects of pressure, temperature, salinity, and NPs concentration on CO2-silica (hydrophilic or hydrophobic) nanofluid γ was thus systematically investigated to understand the influence of nanofluid flooding on CO2 geo-storage. Experiments Pendant drop method was used to measure CO2/nanofluid γ at carbon storage conditions using high pressure-high temperature optical cell. Findings CO2/nano

... Show More
Scopus (68)
Crossref (69)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Materials Research And Technology
The effect of laser pulse energy on ZnO nanoparticles formation by liquid phase pulsed laser ablation
...Show More Authors

Zinc Oxide nanoparticles were prepared using pulsed laser ablation process from a pure zinc metal placed inside a liquid environment. The latter is composed of acetyltrimethylammonium bromide (CTAB) of 10−3 molarity and distilled water. A Ti:Sapphire laser of 800 nm wavelength, 1 kHz pulse repetition rate, 130 fs pulse duration is used at three values of pulse energies of 0.05 mJ, 1.11 mJ and 1.15 mJ. The evaluation of the optical properties for the obtained suspension was applied through ultraviolet–visible absorption spectroscopy test (UV/VIS). The result showed peak wavelengths at 210 nm, 211 nm and 213 nm for the three used pulse energies 0.05 mJ, 1.11 mJ and 1.15 mJ respectively. This indicates a blue shift,

... Show More
View Publication Preview PDF
Scopus (51)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Design and construction Optically Gas Laser
...Show More Authors

In this work the design and construction of a flash photolysis pulsed HCl laser was presented. The parameters of the pumping source and discharge current density was obtained, which sufficient to shift the flash lamp spectrum towards uv portion of spectrum. The maximum pulse laser energy parameters was measured. Total pressure and ratio of active gases to optimized the output pulse energy were measured , where at 125 mbar of total pressure and 1:7:14 Cl2:H2: He ratio, the laser energy was measured to be 200 mJ at pumping four flash lamps energy in the order of 6400J .The resonator consists of copper a near hemispherical mirror with the radius of curvature 3m coated by gold and reflectivity 98%,the output coupler sapphire mirror of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Aug 01 2021
Journal Name
Laser Micro- And Nano-scale Processing
Physical principles of laser–material interaction regimes for laser machining processes
...Show More Authors

Lasers, with their unique characteristics in terms of excellent beam quality, especially directionality and coherency, make them the solution that is key for many processes that require high precision. Lasers have good susceptibility to integrate with automated systems, which provides high flexibility to reach difficult zones. In addition, as a processing tool, a laser can be considered as a contact-free tool of precise tip that became attractive for high precision machining at the micro and nanoscales for different materials. All of the above advantages may be not enough unless the laser technician/engineer has enough knowledge about the mechanism of interaction between the laser light with the processed material. Several sequential phenom

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Jan 15 2020
Journal Name
Iraqi Journal Of Laser
Electronically Implementation and Detection of Pulse Laser from Continuous Laser Diode
...Show More Authors

This research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of en-masse retraction using microimplant versus conventional techniques: An in vitro study
...Show More Authors

Background: The study aimed to investigate the effect of different techniques of en masse retraction on the vertical and sagittal position, axial inclination, rate of space closure, and type of movement of maxillary central incisor. Materials and methods: A typodont simulation system was used (CL II division 2 malocclusion). Three groups were used group 1(N=10, T-loop), group 2(N=10, Time-Saving loop), and group 3(N=10, Microimplant). Photographs were taken before and after retraction and measurements were made using Autodesk AutoCAD© software 2010. Kruskal-Wallis one-way analyses of variance and Mann-Whitney U test (p?0.05) were used. Results: The rate of space closure showed no significant difference among the three groups (p?0.05), whi

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
A review on Activated Carbon Prepared from Agricultural Waste using Conventional and Microwave Activation
...Show More Authors

In the recent years the research on the activated carbon preparation from agro-waste and byproducts have been increased due to their potency for agro-waste elimination. This paper presents a literature review on the synthesis of activated carbon from agro-waste using microwave irradiation method for heating. The applicable approach is highlighted, as well as the effects of activation conditions including carbonization temperature, retention period, and impregnation ratio. The review reveals that the agricultural wastes heated using a chemical process and microwave energy can produce activated carbon with a surface area that is significantly higher than that using the conventional heating method.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 02 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Estimation of the Rock Mechanical Properties Using Conventional Log Data in North Rumaila Field
...Show More Authors

Hydrocarbon production might cause changes in dynamic reservoir properties. Thus the consideration of the mechanical stability of a formation under different conditions of drilling or production is a very important issue, and basic mechanical properties of the formation should be determined. There is considerable evidence, gathered from laboratory measurements in the field of Rock Mechanics, showing a good correlation between intrinsic rock strength and the dynamic elastic constant determined from sonic-velocity and density measurements. The values of the mechanical properties determined from log data, such as the dynamic elastic constants derived from the measurement of the elastic wave velocities in the material, should be more accurate t

... Show More