Background: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by color Doppler at 32 or more weeks of
gestation to determine the possibility of myometrial
invasion depending on the above color Doppler
criteria.
Results: Out of 48 patients eleven exhibited
characteristic Doppler imaging pattern highly specific
for placenta accreta and inccreta according to
preceding criteria , one patient had false positive color
Doppler imaging result, 5 patients underwent
caesarian hysterectomy , the remaining five were
treated conservatively by uterine artery ligation and
other conservative measures because of bleeding
from the lower uterine segment.
Conclusion Color Doppler sonography is highly
sensitive and
specific in the antenatal diagnosis of placenta previa
accreta .If a strong suspicion is found before delivery
,appropriate location and timing for delivery should be
considered ,to allow access to adequate surgical
personel and equipment ,preoperative blood
preparation to reduce morbidity and mortality.
Journal title
Ultrasound in obstetric and gynecology ISSUN 0960-
7692 Source 2000 Vol 15 In 1 PP. 28-35 (22rel)
Abstract Lateral Epicondylitis (LE) which has been referred to as the Tennis Elbow as well is a lesion affecting common tendinous origins of wrist extensors due to chronic overuse injury that results in damaging common extensor tendons which join forearm extensor muscles to humerus. The aim of the present evidence-based clinical statement is reviewing scientific evidences for efficacy of a variety of the rehabilitation methods, chronic lateral epicondylitis management. It is focused upon treating chronic lateral epicondylitis and the latest developments in physiotherapy area for managing chronic lateral epicondylitis. Due to the fact that primary physical impairments in the LE are decreased is the strength of the grip, fundamentally due to
... Show MoreThin films of pure tin mono-sulfide SnS and tin mono-sulfide for (1,2,3,4)% fluorine SnS:F with Thicknesses of (0.85 ±0.05) ?m and (0.45±0.05) ?m respectively were prepared by chemical spray pyrolysis technique. the effect of doping of F on structural and optical properties has been studied. X-Ray diffraction analysis showed that the prepared films were polycrystalline with orthorhombic structure. It was found that doping increased the intensity of diffraction peaks. Optical properties of all samples were studied by recording the absorption and transmission spectrum in range of wave lengths (300-900) nm. The optical energy gap for direct forbidden transi
... Show MoreBackground: This study was done to assist X-ray diffraction and biocompatability of glass ionomer cement reinforced by different ratios of Hydroxyapatite. Materials and Methods: The powder of glass ionomer cement reinforced by different ratios of Hydroxyapatite were used to get X-ray diffraction pattern by X-ray diffraction machine, While for biocompatibility test, A polyethylene tubes containing glass ionomer cement reinforced by different ratios of Hydroxyapatite were implanted on the dorsal submucosal site of Rabbit's tissues and histological slide were prepared for histopathological study. Results: X-ray diffraction test showed that all elements of glass ionomer cement reinforced by different ratios of Hydroxyapatite were react with eac
... Show MoreIn this research, a group of gray texture images of the Brodatz database was studied by building the features database of the images using the gray level co-occurrence matrix (GLCM), where the distance between the pixels was one unit and for four angles (0, 45, 90, 135). The k-means classifier was used to classify the images into a group of classes, starting from two to eight classes, and for all angles used in the co-occurrence matrix. The distribution of the images on the classes was compared by comparing every two methods (projection of one class onto another where the distribution of images was uneven, with one category being the dominant one. The classification results were studied for all cases using the confusion matrix between every
... Show MoreIn the present work, different thicknesses of CdS film were prepared by chemical bath deposition. Z-Scan technique was used to study the nonlinear refractive index and nonlinear absorption coefficients. Linear optical testing were done such as transmission test, and thickness of films were done by the interference fringes (Michelson interferometer). Z-scan experiment was performed at 650nm using CW diode laser and at 532nm wavelength. The results show the effect of self-focusing and defocusing that corresponds with nonlinear refraction n2. The effect of two-photon absorption was also studied, which correspond to the nonlinear absorption coefficient B.
Reaction of L1 [((E)-N1-(nitrobenzylidene)benzene-1,2-diamine] and L2( m-aminophenol), and one equivalent of di- or tri-valent metals(Cr(ӀӀӀ), Mn(ӀӀ), Fe(ӀӀӀ), Co(ӀӀ), Ni(ӀӀ), Cu(ӀӀ) and Zn(ӀӀ) afforded the complexes [M(L1)(L2)2]Cl, M=Cr(ӀӀӀ) and Fe(ӀӀӀ) and the complexes [M(L1)(L2)2] M= Mn(ӀӀ), Co(ӀӀ), Ni(ӀӀ), Cu(ӀӀ) and Zn(ӀӀ). The structure of the Schiff base ligand and their complexes are characterized by (C:H:N), FT.IR, UV.Vis, 1HNMR, 13CNMR and mass spectral. The presence of metal in the complexes are characterized by flame atomic absorption. The spectral data of the complexes have revealed the octahedral geometry. The (L1), (L2) and mixed ligand metal complexes were screened for their ability as cataly
... Show MoreThis paper present a study about effect of the random phase and expansion of the scale sampling factors to improve the monochrome image hologram and compared it with previous produced others. Matlab software is used to synthesize and reconstruction hologram.
The efficient removal of dissolved organic compounds (DOC) from wastewater has become a major environmental concern because of its high toxicity even at low concentrations. Therefore, a technique was needed to reduce these pollutants. Ion exchange technology (IE) was used with AmberliteTM IR120 Na, AmberliteTM IR96RF, and AmberliteTM IR402, firstly by using anion and mixed bed system, where the following variables are investigated for the process of adsorption: The height of the bed in column (8,10 and 14 cm), different concentrations of (DOC) content at constant flow rate. The use of an ion exchanger unit (continuous system) with three columns (cation, anion, and mixed bed) was studied.
... Show MoreThe concern of this article is the calculation of an upper bound of second Hankel determinant for the subclasses of functions defined by Al-Oboudi differential operator in the unit disc. To study special cases of the results of this article, we give particular values to the parameters A, B and λ
Electrodeposition of metal oxides on graphite electrodes can improve their ability to remove organic substances. In this work, multicomponent oxides of Mn, Co, and Ni were electrochemically deposited on both the anode and cathode of graphite electrodes to enhance their performance in removing phenol. Formation of the deposit was achieved within 2 h in current densities of 20, 25, 30, and 35 mA/cm2 for better composite properties. The deposited layer was characterized by testing the surface structure, morphology, composition, and roughness. X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), and Atomic force microscopy (AFM) techniques facilitated these tests. The composite electrodes have synthesized
... Show More