Background: The incidence of maternal mortality in
placenta previa accrete is 7%,and its preoperative
diagnosis is of a great value.
Objective: to evaluate the efficacy of transabdominal
color Doppler ultrasound in diagnosing placenta
previa accreta and inccreta. Color Doppler imaging
criteria used in: includes diffuse parenchymal
placental lacunar flow, focal intra parenchymal
placental lacunar flow and bladder uterine serosa
interphase hyper-vascularity.
Design: Prospective study on patients from
January2007 to January 2008.
Patients and method: 48patients with one caesarean
section or more and with persistent anterior placenta
previa diagnosed by transabdominal ultrasound were
examined by color Doppler at 32 or more weeks of
gestation to determine the possibility of myometrial
invasion depending on the above color Doppler
criteria.
Results: Out of 48 patients eleven exhibited
characteristic Doppler imaging pattern highly specific
for placenta accreta and inccreta according to
preceding criteria , one patient had false positive color
Doppler imaging result, 5 patients underwent
caesarian hysterectomy , the remaining five were
treated conservatively by uterine artery ligation and
other conservative measures because of bleeding
from the lower uterine segment.
Conclusion Color Doppler sonography is highly
sensitive and
specific in the antenatal diagnosis of placenta previa
accreta .If a strong suspicion is found before delivery
,appropriate location and timing for delivery should be
considered ,to allow access to adequate surgical
personel and equipment ,preoperative blood
preparation to reduce morbidity and mortality.
Journal title
Ultrasound in obstetric and gynecology ISSUN 0960-
7692 Source 2000 Vol 15 In 1 PP. 28-35 (22rel)
In this study, we present a new steganography method depend on quantizing the perceptual color spaces bands. Four perceptual color spaces are used to test the new method which is HSL, HSV, Lab and Luv, where different algorithms to calculate the last two-color spaces are used. The results reveal the validity of this method as a steganoic method and analysis for the effects of quantization and stegano process on the quality of the cover image and the quality of the perceptual color spaces bands are presented.
<span>We present the linearization of an ultra-wideband low noise amplifier (UWB-LNA) operating from 2GHz to 11GHz through combining two linearization methods. The used linearization techniques are the combination of post-distortion cancellation and derivative-superposition linearization methods. The linearized UWB-LNA shows an improved linearity (IIP3) of +12dBm, a minimum noise figure (NF<sub>min.</sub>) of 3.6dB, input and output insertion losses (S<sub>11</sub> and S<sub>22</sub>) below -9dB over the entire working bandwidth, midband gain of 6dB at 5.8GHz, and overall circuit power consumption of 24mW supplied from a 1.5V voltage source. Both UWB-LNA and linearized UWB-LNA designs are
... Show MoreBackground: Deep vein thrombosis is a multi causal disease and its one of most common venous disorder, but only one quarter of the patients who have signs and symptoms of a clot in the vein actually have thrombosis and need treatment .The disease can be difficult to diagnose. Venous ultrasound in combination with clinical finding is accurate for venous thromboembolism, its costly because a large number of patients with suspicious signs and symptoms. Venography still the gold standard for venous thromboembolism but it is invasive. The D-dimer increasingly is being seen as valuable tool rolling out venous thromboembolism and sparing low risk patients for further workup.Objectives: this study has designed the role of D-dimer to confirm diag
... Show MorePresentation of urinary calculus ranges from painful urination to acute retention. Diagnosed by x-ray pelvis and non-contrast CT and removal of stone by various methods is the management. Variety in symptoms, sometimes make clinical diagnosis difficult until radiological investigations confirm it. In this case presentation, initial diagnosis was made of Urethrocutaneous fistula may be due to distal stricture, but on investigating, he was diagnosed as urethral calculus in urethral diverticulum , as the reason for his symptoms
The aim of this study was to evaluate ovarian masses with conventional grey scale ultrasonography and colour Doppler flow imaging and to assess the diagnostic reliability of these methods in differentiating benign and malignant ovarian masses.
We assessed 56 patients with an ovarian mass. Morphological characterisation of the mass was performed utilising the Sassone score. Colour Doppler parameters were recorded for each patient, and the Caruso vascular score was also applied. The results were compared with surgical/pathological and/or follow-up scans.
Using the Sassone score, overall reliability in differentiating ovaria
Background: Breast cancer is the first one among Iraqi females. Most of them present later for diagnosis. Early detection center in tertiary hospital practice uses FNAB for early diagnosis. Publications on accuracy of this detection are scarce.
Objective: To test the accuracy of FNAB in breast lump diagnosis.
Methods: Diagnostic test accuracy study, on 204 women with breast lump, attending the oncology department in 2017.
Results: Fine-needle aspiration biopsy diagnosis of histologically malignant cases were, malignant in 89 (87.3%), suspicious of malignancy in 5 (4.9%), and benign in 4 (3.9%). Complete sensitivity was 87.3%, and specificity
... Show MoreThis research evaluated the effect of (UV)(400-320A)Hz(320-220B)Hz on the patient with vitiligo , using it with our new combing therapy that include the oral (Psorlene ) topical , meladinine solution applied on the Vitiligiousns Lesions , In edition to the instralesnional injection in the Vitiligiousns Lesions by long acting steroid (kenacort-A ) by aprecentage of (5%) , after that we expose the patient to UV . The ruslets of this way of treatment more effective by using of the UV rays in the treatment of vitiligo , while the previous treatment that used the UV ray with or with out the psorlene , the results were not effective on controlling of the Vitiligio diseases comparing by the treatment used in this research as it stop’s the sp
... Show MoreOcular drug delivery is challenging due to the presence of anatomical and physiological barriers. These barriers can affect drug entry into the eye following multiple routes of administration (e.g., topical, systemic, and injectable). Topical administration in the form of eye drops is preferred for treating anterior segment diseases, as it is convenient and provides local delivery of drugs. Major concerns with topical delivery include poor drug absorption and low bioavailability. To improve the bioavailability of topically administered drugs, novel drug delivery systems are being investigated. Nanocarrier delivery systems demonstrate enhanced drug permeation and prolonged drug release. This review provides an overview of ocular barr
... Show More