Background: Polycystic ovary syndrome (PCOS) is
the most common form of chronic anovulation
associated with androgen excess; it occurs in about 5
– 10% 0f reproductive age women. Metabolic
syndrome is characterized by insulin resistance,
hypertension, obesity, abnormalities of blood clotting
and dyslipidemia.
Adult women with PCOS have an increased
prevalence of the metabolic syndrome(MBS).
Objectives: To detect the prevalence of metabolic
syndrome in women with proved PCOS, attending the
Specialized Center for Endocrinology and Diabetes, in
Baghdad.
Materials and methods : A total number of 40
women with proved PCOS were included in this study
which was conducted in the Specialized Center for
Endocrinology and Diabetes-Baghdad, over a period
of 5 months(from April till September 2005).In
addition to measuring waist circumference and body
mass index(BMI),all patients were tested for the
levels of C-peptide, Fasting plasma glucose(FPG),
Serum luteinizing hormone(LH), Follicle st –
imulating hormone(FSH), Prolactin(PRL),
Progesterone, estradiol(E2), testosterone,T3,T4 and
TSH .
Also lipid profile, glycated hemoglobin(HbA1c) were
estimated to all patients. Glucose tolerance test(GTT)
using 75 gm of glucose was performed on all patients.
Results: Out of 40 women with PCOS,eleven
patients(27.5%) have impaired GTT. Twenty patients
(50%) out of 40 fulfil the criteria of the International
Diabetes Fideration(IDF)
Consensus Definition of the metabolic
syndrome(MBS)-2005.
Thirty-Seven patients(92.5%) have a waist
circumference more than 80 cm.
Thirty-two patients(80%) have secondary amenorrhea.
Hirsuitism and increased BMI(body mass index) were
present in 33 patients(82.5%)
The mean C-peptide level was higher in those patients
who had impaired GTT(11 patients),meaning that
GTT can be used to detect insulin resistance specially
in Labs. where measurements of insulin levels are not
available.
Conclusions :
1. Metabolic syndrome is present in 50% of our
patients,using the IDF Consensus Definition of
the metabolic syndrome-2005.
2. Glucose tolerance test can be used to detect the
presence of insulin resistance specially in Labs.
where measurements of insulin levels are not
available.
3. Insulin resistance is present in 27.5% in women
with PCOS who were included in our study.
The present investigation focuses on the response of simply supported reinforced concrete rectangular-section beams with multiple openings of different sizes, numbers, and geometrical configurations. The advantages of the reinforcement concrete beams with multiple opening are mainly, practical benefit including decreasing the floor heights due to passage of the utilities through the beam rather than the passage beneath it, and constructional benefit that includes the reduction of the self-weight of structure resulting due to the reduction of the dead load that achieves economic design. To optimize beam self-weight with its ultimate resistance capacity, ten reinforced concrete beams having a length, width, and depth of 2700, 100, and
... Show MoreIn this paper, we study, in details the derivation of the variational formulation corresponding to functional with deviating arguments corresponding to movable boundaries. Natural or transversility conditions are also derived, as well as, the Eulers equation. Example has been taken to explain how to apply natural boundary conditions to find extremal of this functional.
In this research, nanofibers have been prepared by using an electrospinning method. Three types of polymer (PVA, VC, PMMA) have been used with different concentration. The applied voltage and the gap length were changed. It was observed that VC is the best polymer than the other types of polymers.
The polymeric hydrogels composed of poly vinyl alcohol (m.wt 72000) and glutaraldehyde(5%,8% and 10%) , have been thermally prepared for the purpose of studying their swelling and drug release behavior . The swelling ratio was measured for all the hydrogel samples at 37°C, in three different media pH (1.2, 4.7 and 6.8) as a function of time. The results show that the maximum swelling ratios were arranged as follows :pH =6.8 > pH =4.7 > pH =1.2 hydrogels cross linked PVA showed a typical pH responsive behavior such as high pH has maximum swelling while low pH shows minimum swelling.
The present work is concerned with the investigation of the behavior and ultimate capacity of axially loaded reinforced concrete columns in presence of transverse openings under axial load plus uniaxial bending. The experimental program includes testing of twenty reinforced concrete columns (150 × 150 × 700 mm) under concentric and eccentric load. Parameters considered include opening size, load eccentricity and influence of the direction of load eccentricity with respect to the longitudinal axis of the opening. Experimental results are discussed based on load – lateral mid height deflection curves, load – longitudinal shortening behavior, ultimate load and failure modes. It is found that when the direction of load
... Show MoreThis paper deals with constructing a model of fuzzy linear programming with application on fuels product of Dura- refinery , which consist of seven products that have direct effect ondaily consumption . After Building the model which consist of objective function represents the selling prices ofthe products and fuzzy productions constraints and fuzzy demand constraints addition to production requirements constraints , we used program of ( WIN QSB ) to find the optimal solution
This paper is concerned with the oscillation of all solutions of the n-th order delay differential equation . The necessary and sufficient conditions for oscillatory solutions are obtained and other conditions for nonoscillatory solution to converge to zero are established.
Using fiber-reinforced polymer (FRP) could effectively improve the strength and endurance of reinforced concrete (RC) constructions. This study evaluated the flexural behavior of one-way concrete slabs with openings reinforced with glass fiber-reinforced polymers (GFRP) bars. It strengthened using carbon fiber-reinforced polymer (CFRP) sheets around the openings. The experimental program of this study is adopted by casting and testing four one-way concrete slabs with dimensions of (150*750*2650) mm. These slabs are divided into two groups based on whether they were strengthened or un-strengthened. For each group, two different openings (either one rectangular or two square) measured 250*500 mm and 250*250 mm, respective
... Show MoreThe purpose of this paper is to introduce and prove some coupled coincidence fixed point theorems for self mappings satisfying -contractive condition with rational expressions on complete partially ordered metric spaces involving altering distance functions with mixed monotone property of the mapping. Our results improve and unify a multitude of coupled fixed point theorems and generalize some recent results in partially ordered metric space. An example is given to show the validity of our main result.