Background: Polycystic ovary syndrome (PCOS) is
the most common form of chronic anovulation
associated with androgen excess; it occurs in about 5
– 10% 0f reproductive age women. Metabolic
syndrome is characterized by insulin resistance,
hypertension, obesity, abnormalities of blood clotting
and dyslipidemia.
Adult women with PCOS have an increased
prevalence of the metabolic syndrome(MBS).
Objectives: To detect the prevalence of metabolic
syndrome in women with proved PCOS, attending the
Specialized Center for Endocrinology and Diabetes, in
Baghdad.
Materials and methods : A total number of 40
women with proved PCOS were included in this study
which was conducted in the Specialized Center for
Endocrinology and Diabetes-Baghdad, over a period
of 5 months(from April till September 2005).In
addition to measuring waist circumference and body
mass index(BMI),all patients were tested for the
levels of C-peptide, Fasting plasma glucose(FPG),
Serum luteinizing hormone(LH), Follicle st –
imulating hormone(FSH), Prolactin(PRL),
Progesterone, estradiol(E2), testosterone,T3,T4 and
TSH .
Also lipid profile, glycated hemoglobin(HbA1c) were
estimated to all patients. Glucose tolerance test(GTT)
using 75 gm of glucose was performed on all patients.
Results: Out of 40 women with PCOS,eleven
patients(27.5%) have impaired GTT. Twenty patients
(50%) out of 40 fulfil the criteria of the International
Diabetes Fideration(IDF)
Consensus Definition of the metabolic
syndrome(MBS)-2005.
Thirty-Seven patients(92.5%) have a waist
circumference more than 80 cm.
Thirty-two patients(80%) have secondary amenorrhea.
Hirsuitism and increased BMI(body mass index) were
present in 33 patients(82.5%)
The mean C-peptide level was higher in those patients
who had impaired GTT(11 patients),meaning that
GTT can be used to detect insulin resistance specially
in Labs. where measurements of insulin levels are not
available.
Conclusions :
1. Metabolic syndrome is present in 50% of our
patients,using the IDF Consensus Definition of
the metabolic syndrome-2005.
2. Glucose tolerance test can be used to detect the
presence of insulin resistance specially in Labs.
where measurements of insulin levels are not
available.
3. Insulin resistance is present in 27.5% in women
with PCOS who were included in our study.
Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.
Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)
Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO
... Show MoreIn present study, the technique was used, including nuclear track detector type (CR-39), for appreciative concentrations uranium and radon in soil samples from Baghdad University Campus-AL-Jadiriyah utilizing a prolonged -term with a solid-state nuclear path sensor, a technique for charged particles has been developed., the radon concentrations, effective dose rate and uranium concentrations have measured in soil samples. Eight various venues from soil Baghdad University Campus have appointed. The results indicated variant values about uranium and radon concentrations, the average value for radon gas, effective dose rate and uranium concentrations was found to be 281.59 Bq/cm3, 7.09 mSv/y and 0.01 Bq/mm-2 respectively. All results a
... Show MoreA single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1
... Show MoreIn this research the Empirical Bayes method is used to Estimate the affiliation parameter in the clinical trials and then we compare this with the Moment Estimates for this parameter using Monte Carlo stimulation , we assumed that the distribution of the observation is binomial distribution while the distribution with the unknown random parameters is beta distribution ,finally we conclude that the Empirical bayes method for the random affiliation parameter is efficient using Mean Squares Error (MSE) and for different Sample size .
Retreatment Efficacy of Continuous Rotation Versus Reciprocation Kinematic Movements in Removing Gutta-Percha with Calcium Silicate-Based Sealer: SEM Study, Raghad Noori Nawaf*, Ra