Preferred Language
Articles
/
jkmc-658
Metabolic syndrome in women with polycystic ovary syndrome
...Show More Authors

Background: Polycystic ovary syndrome (PCOS) is
the most common form of chronic anovulation
associated with androgen excess; it occurs in about 5
– 10% 0f reproductive age women. Metabolic
syndrome is characterized by insulin resistance,
hypertension, obesity, abnormalities of blood clotting
and dyslipidemia.
Adult women with PCOS have an increased
prevalence of the metabolic syndrome(MBS).
Objectives: To detect the prevalence of metabolic
syndrome in women with proved PCOS, attending the
Specialized Center for Endocrinology and Diabetes, in
Baghdad.
Materials and methods : A total number of 40
women with proved PCOS were included in this study
which was conducted in the Specialized Center for
Endocrinology and Diabetes-Baghdad, over a period
of 5 months(from April till September 2005).In
addition to measuring waist circumference and body
mass index(BMI),all patients were tested for the
levels of C-peptide, Fasting plasma glucose(FPG),
Serum luteinizing hormone(LH), Follicle st –
imulating hormone(FSH), Prolactin(PRL),
Progesterone, estradiol(E2), testosterone,T3,T4 and
TSH .
Also lipid profile, glycated hemoglobin(HbA1c) were
estimated to all patients. Glucose tolerance test(GTT)
using 75 gm of glucose was performed on all patients.
Results: Out of 40 women with PCOS,eleven
patients(27.5%) have impaired GTT. Twenty patients
(50%) out of 40 fulfil the criteria of the International
Diabetes Fideration(IDF)
Consensus Definition of the metabolic
syndrome(MBS)-2005.
Thirty-Seven patients(92.5%) have a waist
circumference more than 80 cm.
Thirty-two patients(80%) have secondary amenorrhea.
Hirsuitism and increased BMI(body mass index) were
present in 33 patients(82.5%)
The mean C-peptide level was higher in those patients
who had impaired GTT(11 patients),meaning that
GTT can be used to detect insulin resistance specially
in Labs. where measurements of insulin levels are not
available.
Conclusions :
1. Metabolic syndrome is present in 50% of our
patients,using the IDF Consensus Definition of
the metabolic syndrome-2005.
2. Glucose tolerance test can be used to detect the
presence of insulin resistance specially in Labs.
where measurements of insulin levels are not
available.
3. Insulin resistance is present in 27.5% in women
with PCOS who were included in our study.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Modeling of Electron and Lattice Temperature Distribution Through Lifetime of Plasma Plume
...Show More Authors

When employing shorter (sub picosecond) laser pulses, in ablation kinetics the features appear which can no longer be described in the context of the conventional thermal model. Meanwhile, the ablation of materials with the aid of ultra-short (sub picosecond) laser pulses is applied for micromechanical processing. Physical mechanisms and theoretical models of laser ablation are discussed. Typical associated phenomena are qualitatively regarded and methods for studying them quantitatively are considered. Calculated results relevant to ablation kinetics for a number of substances are presented and compared with experimental data. Ultra-short laser ablation with two-temperature model was quantitatively investigated. A two-temperature model

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
Comparison Study of Plasma-Activated Water and Plasma Jet Effects on Escherichia coli Bacteria for the Disinfection of Tooth Root Canal
...Show More Authors

This study compares the effects of plasma jet and plasma-activated water on teeth root canals contaminated with Escherichia coli bacteria. A plasma jet system was developed for biological purposes that operate at atmospheric pressure. The plasma jet works with argon gas and is generated by a power supply, which supplies a sinusoidal alternating voltage of 12 kV of 20 kHz frequency. The system was optically diagnosed, as it was found that the peaks of the nitrogen spectrum were obtained at the wavelength (300- 450) nm with the appearance of hydroxide peaks at 380 nm. Extracted teeth with one root canal were used, which were contaminated with bacteria and divided into two groups to be treated with a plasma jet and plasma-activated

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed May 25 2022
Journal Name
Iraqi Journal Of Science
Optical Properties of Manufactured Mirrors Using DC Plasma Magnetron Sputtering Technique
...Show More Authors

    This paper defines a method for sputtering high strength, extremely conductive silver mirrors on glass substrates at temperatures ranging from 20o to 22o C. The silver coated layer thicknesses in this work ranges from 7.5 to 16.1 nm using sputtering time from 10 to 30 min at power 25 W, 13.7 to 29.2 nm for time 10 to 30 min at 50 W, 15.7 to 26.4 nm for time 10 to 30 min at 75 W and 13.8 to 31.1 nm for time 10 to 30 min at 100 W. The optimum values of pressure and electrode gape for plasma sputtering system are 0.1 mbar and 5 cm respectively. The effect of DC sputtering power, sputtering duration or (sputtering time), and thickness on optical properties was investigated using an ultraviolet-visible spectrophot

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Science
The Effect of Axial Magnetic Field on The Breakdown Voltage of Air at Low Pressure
...Show More Authors

To add more details about the effect of the axial magnetic field on the plasma profile, the breakdown voltage of air was investigated at low pressure (9-15 Pa) in the presence of axial magnetic field (0.01-0.04T). The air was ignited by a DC voltage between two plain electrodes of aluminum separated by a distance (8.5cm). The measurements showed that the discharge voltage decreases to a minimum value, then returns to increase over the minimum with increasing the magnetic field strength, at all pressures in the range. It was also observed that a maximum decrease in the discharge voltage is obtained near the minimum of  Paschen curve from the right side. The decrease in the discharge voltage was caused mainly by the effect of magnetic

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
Investigate and Prepare silver Nano Particles Using Jet Plasma
...Show More Authors

Nano- particles (Ag NPs) are synthesized by using plasma Jet  argon gas. The prepared Ag NPs are characterized by Atomic Absorption Spectroscopy (AAS) The measure was performed for different time exposuring 15,30,45 and 60 sec. The results shows the low concentration of nano-silver time expose (15 sec) and very) and high concentration at 60 sec. The UV-VIS spectrometer for nano-silver different time exsposuring to plasma, shows the Surface Plasmon Resonance (SPR) appeared around 419 nm, and the  energy gab is 4.1 eV for the 15 second exposure and 1.6eV for 60 second exposure.  The Scanning Probe Microscope (SPM) is used to identify the characterization of silver  nanoparticles, the average diameter of nano-silver  for 15 second exp

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Crossref
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Science
Plasma diagnostic of gliding arc discharge at atmospheric pressure
...Show More Authors

A gliding arc discharge (GAD) with a water spray system was constructed. A non-thermal plasma, generated between two V shaped electrodes in an ambient argon driven by 100 Hz AC voltage, was investigated using optical emission spectroscopy (OES) with different gas flow rates (0.5, 1, 1.5, 2 , 2.5 , 3  1/min). Boltzmann plot method was used to calculate electron temperature (Te) and electron density (ne). The electrodes design was spectrally recognized and its Te value was about 0.588-0.863 eV, while the ne value of 6.875×1017-10.938×1017 cm-3. The results of the plasma diagnostics generated by gliding arc showed that increasing gas f

... Show More
View Publication Preview PDF
Scopus (26)
Crossref (10)
Scopus Crossref
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Fabrication and Characterization of Gas Sensor from ZrO2: MgO Nanostructure Thin Films by R.F. Magnetron Sputtering Technique
...Show More Authors

Thin films ZrO2: MgO nanostructure have been synthesized by a radio frequency magnetron plasma sputtering technique at different ratios of MgO (0,6, 8 and  10)% percentage to be used as the gas sensor for nitrogen dioxide NO2. The samples were investigated by X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) and sensing properties were also investigated. The average particle size of all prepared samples was found lower than 33.22nm and the structure was a monoclinic phase. The distribution of grain size was found lower than36.3 nm and uninformed particles on the surface. Finally, the data of sensing properties have been discussed, where the

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Results In Physics
Alpha clustering preformation probability in even-even and odd-A<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="d1e3355" altimg="si39.svg"><mml:msup><mml:mrow /><mml:mrow><mml:mn>270</mml:mn><mml:mo>−</mml:mo><mml:mn>317</mml:mn></mml:mrow></mml:msup></mml:math>(116 and 117) using cluster formation model and the mass formulae : KTUY05 and WS4
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
The effect of the cold atmospheric plasma on the number of platelets
...Show More Authors

This study includes the direct influence of (single & multi) dose of Cold Atmospheric Plasma (CAP) on the no. of platelets for mice for different exposure time (15, 30, 60, and 120) sec. the influence of CAP on mice was measured after 1, 2, 3, 7, and 14 day from exposure.
The results obtained in this study indicate that the effect of low doses of CAP on platelets was stimulatory effect in the first few hours from exposure (1day) but the high dose was inhibitory, It was found that after two weeks of exposure that the number of platelets became normal comparable to the control one, and this indicates that plasma effect was removed after this period.

View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Optical and structural study for DLC thin films prepared by plasma jet
...Show More Authors

Diamond-like carbon (DLC) homogeneous thin films were deposited from cyclohexane (Ccyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (C 6H12 ) liquid by using a plasma jet system which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with al

... Show More
View Publication Preview PDF
Crossref