Background: Polycystic ovary syndrome (PCOS) is
the most common form of chronic anovulation
associated with androgen excess; it occurs in about 5
– 10% 0f reproductive age women. Metabolic
syndrome is characterized by insulin resistance,
hypertension, obesity, abnormalities of blood clotting
and dyslipidemia.
Adult women with PCOS have an increased
prevalence of the metabolic syndrome(MBS).
Objectives: To detect the prevalence of metabolic
syndrome in women with proved PCOS, attending the
Specialized Center for Endocrinology and Diabetes, in
Baghdad.
Materials and methods : A total number of 40
women with proved PCOS were included in this study
which was conducted in the Specialized Center for
Endocrinology and Diabetes-Baghdad, over a period
of 5 months(from April till September 2005).In
addition to measuring waist circumference and body
mass index(BMI),all patients were tested for the
levels of C-peptide, Fasting plasma glucose(FPG),
Serum luteinizing hormone(LH), Follicle st –
imulating hormone(FSH), Prolactin(PRL),
Progesterone, estradiol(E2), testosterone,T3,T4 and
TSH .
Also lipid profile, glycated hemoglobin(HbA1c) were
estimated to all patients. Glucose tolerance test(GTT)
using 75 gm of glucose was performed on all patients.
Results: Out of 40 women with PCOS,eleven
patients(27.5%) have impaired GTT. Twenty patients
(50%) out of 40 fulfil the criteria of the International
Diabetes Fideration(IDF)
Consensus Definition of the metabolic
syndrome(MBS)-2005.
Thirty-Seven patients(92.5%) have a waist
circumference more than 80 cm.
Thirty-two patients(80%) have secondary amenorrhea.
Hirsuitism and increased BMI(body mass index) were
present in 33 patients(82.5%)
The mean C-peptide level was higher in those patients
who had impaired GTT(11 patients),meaning that
GTT can be used to detect insulin resistance specially
in Labs. where measurements of insulin levels are not
available.
Conclusions :
1. Metabolic syndrome is present in 50% of our
patients,using the IDF Consensus Definition of
the metabolic syndrome-2005.
2. Glucose tolerance test can be used to detect the
presence of insulin resistance specially in Labs.
where measurements of insulin levels are not
available.
3. Insulin resistance is present in 27.5% in women
with PCOS who were included in our study.
The aim of the present study is to evaluate the change in the levels of glucagon, GLP-1 and GPCR in diabetic patient's and diabetic with dyslipidemia as metabolic syndrome. The study included 75 male aged ranged (30-50) years and with BMI (25-29) kg/m2 which divided into three groups as follows: group one (G1): consist of 25 subjects as healthy control group. Group two (G2): consist of 25 patient's with diabetes mellitus and group three (G3): consist of 25 patient's with diabetic and dyslipidemia as metabolic syndrome. Serum was used in determination of FBG, lipid profile, insulin, glucagon, GLP-1 and GPCR. Whole blood was determination of HbA1c. The results revealed significant elevation in FBG and HbA1c in G2 and G3 comparing to G1. While
... Show MoreThe aim of the current research is to study the effect of adding green tea to the edible film prepared from the whey protein isolate on the effectiveness of microorganisms and evaluating the of antimicrobial effectiveness of these films on Iraqi soft cheese packaging during the nine days of storage as an alternative to commercial packaging. At the beginning of the study, the minimum inhibitory concentration was measured by calculate the diameter of the zone of inhibition on growth of the bacteria and it's included the group of Gram negative bacteria (Escherichia coli, Salmonella spp, Pseudomonas Aeruginosa) and the group of Gram positive bacteria (Staphylococcus Aureus, Bacillus spp) and a yeast (Candida Albican). Where the diameter of t
... Show MoreThis study was conducted to determine the side effects of dexamethasone n some physiological and immunological criteria, which included, Measuring sugar level, liver (ALT, AST , LDH, Total protein) and kidney function (urea, createnine), total and differential count of W.B.C,CRP, TNF-α ,IL6,IL10. thirty rats were divided into two groups (15\ rat). G1: This group was considered negative control injection with normal saline, G2: This group was injected with 2 mg\kg dexamethasone. The results showed a significant increase in the level of enzymesALT, AST and sugar levels and decreased level of total protein in the group treated with the drug, also showed, a significant decrease in the total number of W.B.C an
... Show MoreThe problem of Bi-level programming is to reduce or maximize the function of the target by having another target function within the constraints. This problem has received a great deal of attention in the programming community due to the proliferation of applications and the use of evolutionary algorithms in addressing this kind of problem. Two non-linear bi-level programming methods are used in this paper. The goal is to achieve the optimal solution through the simulation method using the Monte Carlo method using different small and large sample sizes. The research reached the Branch Bound algorithm was preferred in solving the problem of non-linear two-level programming this is because the results were better.
The present work included study of the effects of weather conditions such as solar radiation and ambient temperature on solar panels (monocrystalline 30 Watts) via proposed mathematical model, MATLAB_Simulation was used by scripts file to create a special code to solve the mathematical model , The latter is single –diode model (Five parameter) ,Where the effect of ambient temperature and solar radiation on the output of the solar panel was studied, the Newton Raphson method was used to find the output current of the solar panel and plot P-V ,I-V curves, the performance of the PV was determined at Standard Test Condition (STC) (1000W/m2)and a comparison between theoretical and experimental results were done .The best efficiency
... Show MoreThis work is concerned with the vibration attenuation of a smart beam interacting with fluid using proportional-derivative PD control and adaptive approximation compensator AAC. The role of the AAC is to improve the PD performance by compensating for unmodelled dynamics using the concept of function approximation technique FAT. The key idea is to represent the unknown parameters using the weighting coefficient and basis function matrices/vectors. The weighting coefficient vector is updated using Lyapunov theory. This controller is applied to a flexible beam provided with surface bonded piezo-patches while the vibrating beam system is submerged in a fluid. Two main effects are considered: 1) axial stretching of the vibrating beam that leads
... Show MoreObjective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time expo
... Show MoreCardiovascular disorders are refer to the class of diseases that involve the heart or blood vessels (arteries and veins). While the term technically refers to any disease that affects the cardiovascular system. Cholesterol is classified as a sterol (a contraction of steroid and
... Show MoreThis paper aims to improve the voltage profile using the Static Synchronous Compensator (STATCOM) in the power system in the Kurdistan Region for all weak buses. Power System Simulation studied it for Engineers (PSS\E) software version 33.0 to apply the Newton-Raphson (NR) method. All bus voltages were recorded and compared with the Kurdistan region grid index (0.95≤V ≤1.05), simulating the power system and finding the optimal size and suitable location of Static Synchronous Compensator (STATCOM)for bus voltage improvement at the weakest buses. It shows that Soran and New Koya substations are the best placement for adding STATCOM with the sizes 20 MVAR and 40 MVAR. After adding STATCOM with the sizes [20MVAR and 40MV
... Show More