Preferred Language
Articles
/
jkmc-654
MODIFIED ALVARADO SCORING SYSTEM. HOW MUCH HELPFUL?
...Show More Authors

Background:-The Modified Alvarado Scoring
System (MASS) has been reported to be a cheap
and quick diagnostic tool in patients with acute
appendicitis. However, differences in diagnostic
accuracy have been observed if the scores were
applied to various populations and clinical settings.
Objectives:- The purpose of this study was to
evaluate the diagnostic value of Modified Alvarado
Scoring System in patients with acute appendicitis
in our setting.
Methods:-one hundre twenty eight patients, were
included in this study, admitted to Al-Kindy
teaching hospital from June 2009 to June 2010.
Patients’ age ranged from 8 to 56 years (21±10)
they were divided into three groups; paediatrics,
child bearing age females & adult males,. MASS
was calculated for each patient included as the
diagnosis & treatment were done on the bases of
surgeon's clinical decision,confirmation was done
by histopathological examination. Finally statistics
done included negative appendectomy rate,
sensitivity, specificity, positive predictive
value,negative predictive value & accuracy.
Results: - Our negative appendectomy rate was
19.5% (22.22% for paediatrics 40.9% for females
4.2% for males). MASS showed sensitivity of
61%(92.8% for paediatrics 38% for females & 58%
for males), specificity 80% (75% for paediatrics
88% for females & 50% for males), positive
predictive value 92%(92.8% for paediatrics 83%
for females 50% for males), negative predictive
value 33% (75%for paediatrics 50% for females
5% for males) & accuracy 65% (88.9% for
paediatrics 59% for females 58% for males).
Conclusion:- MASS was of limited help to junior
doctors in our setting,clinical assessment &
experience are still the gold standard for acute
appendicitis.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System
...Show More Authors

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 14 2021
Journal Name
Egyptian Journal Of Chemistry
Real wastewater Treatment by Electrocoagulation- Electro-oxidation Combined System: Optimization using Taguchi Approach
...Show More Authors

In this study, the optimum conditions for COD removal from petroleum refinery wastewater by using a combined electrocoagulation- electro-oxidation system were attained by Taguchi method. An orthogonal array experimental design (L18) which is of four controllable parameters including NaCl concentration, C.D. (current density), PH, and time (time of electrolysis) was employed. Chemical oxygen demand (COD) removal percentage was considered as the quality characteristics to be enhanced. Also, the value of turbidity and TDS (total dissolved solid) were estimated. The optimum levels of the studied parameters were determined precisely by implementing S/N analysis and analysis of variance (ANOVA). The optimum conditions were found to be NaCl = 2.5

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering
Design And Analysis Performance of Liquid Petroleum Gases System in Residential Building; Review
...Show More Authors

Liquefied petroleum gases (LPG) consist of hydrocarbons obtained by refining crude oil, either from propane or butane or a mixture of the two. There are often other components such as propylene, butylene or other hydrocarbons, but they are not the main component. The study aims to review previous studies dealing with designing an LPG system to deliver gas to residential campuses and buildings. LPG is extracted from natural gas NG by several processes, passing through fractionation towers and then pressuring into CNG storage tanks. Gas contains several problems, including gas leakage through the pipes and leads to fires or explosions in LPG storage and distribution tanks, so safety conditions were taken in the design and implementation. T

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Applied Thermal Engineering
Solidification of a PCM with nanoparticles in triplex-tube thermal energy storage system
...Show More Authors

Crossref (171)
Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Iop Conference Series: Earth And Environmental Science
Smart Irrigation Technique in the Fixed Irrigation System Based on Soil Moisture Content
...Show More Authors
Abstract<p>The growing water demand has raised serious concerns about the future of irrigated agriculture in many parts all over the world, changing environmental conditions and shortage of water (especially in Iraq) have led to the need for a new system that efficiently manages the irrigation of crops. With the increasing population growing at a rapid pace, traditional agriculture will have a tough time meeting future food demands. Water availability and conservation are major concerns for farmers. The configuration of the smart irrigation system was designed based on data specific to the parameters concerning the characteristics of the plant and the properties of soil which are measured once i</p> ... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jan 09 2021
Journal Name
Journal Of Control, Automation And Electrical Systems
Design of an Adaptive Linear Quadratic Regulator for a Twin Rotor Aerodynamic System
...Show More Authors

View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Ieee Access
Single-Phase Grid-Tied Transformerless Inverter of Zero Leakage Current for PV System
...Show More Authors

View Publication
Scopus (59)
Crossref (53)
Scopus Clarivate Crossref
Publication Date
Wed Mar 24 2021
Journal Name
Ieee Access
Smart IoT Network Based Convolutional Recurrent Neural Network With Element-Wise Prediction System
...Show More Authors

An Intelligent Internet of Things network based on an Artificial Intelligent System, can substantially control and reduce the congestion effects in the network. In this paper, an artificial intelligent system is proposed for eliminating the congestion effects in traffic load in an Intelligent Internet of Things network based on a deep learning Convolutional Recurrent Neural Network with a modified Element-wise Attention Gate. The invisible layer of the modified Element-wise Attention Gate structure has self-feedback to increase its long short-term memory. The artificial intelligent system is implemented for next step ahead traffic estimation and clustering the network. In the proposed architecture, each sensing node is adaptive and able to

... Show More
Scopus (14)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of a Power System Transient Stability Using Static Synchronous Series Compensator SSSC
...Show More Authors

Static Synchronous Series Compensator (SSSC) is a well known device for effectively regulating the active power flow in a power system. In this paper, the SSSC linearized power flow equations are incorporated into Newton-Raphson algorithm in a MATLAB written program to investigate the control of active poweer flow and the transient stability of a five bus and a thirty bus IEEE test systems, during abnormal conduction (three phase fault near buses). A comparison of the results obtained for the base case without SSSC and with it to investigate the effectiveness of the device on both of the active power flow and the transient stability.

View Publication Preview PDF
Publication Date
Fri Nov 01 2019
Journal Name
2019 1st International Informatics And Software Engineering Conference (ubmyk)
Radial Basis Function (RBF) Based on Multistage Autoencoders for Intrusion Detection system (IDS)
...Show More Authors

In this paper, RBF-based multistage auto-encoders are used to detect IDS attacks. RBF has numerous applications in various actual life settings. The planned technique involves a two-part multistage auto-encoder and RBF. The multistage auto-encoder is applied to select top and sensitive features from input data. The selected features from the multistage auto-encoder is wired as input to the RBF and the RBF is trained to categorize the input data into two labels: attack or no attack. The experiment was realized using MATLAB2018 on a dataset comprising 175,341 case, each of which involves 42 features and is authenticated using 82,332 case. The developed approach here has been applied for the first time, to the knowledge of the authors, to dete

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref