Background:-The Modified Alvarado Scoring
System (MASS) has been reported to be a cheap
and quick diagnostic tool in patients with acute
appendicitis. However, differences in diagnostic
accuracy have been observed if the scores were
applied to various populations and clinical settings.
Objectives:- The purpose of this study was to
evaluate the diagnostic value of Modified Alvarado
Scoring System in patients with acute appendicitis
in our setting.
Methods:-one hundre twenty eight patients, were
included in this study, admitted to Al-Kindy
teaching hospital from June 2009 to June 2010.
Patients’ age ranged from 8 to 56 years (21±10)
they were divided into three groups; paediatrics,
child bearing age females & adult males,. MASS
was calculated for each patient included as the
diagnosis & treatment were done on the bases of
surgeon's clinical decision,confirmation was done
by histopathological examination. Finally statistics
done included negative appendectomy rate,
sensitivity, specificity, positive predictive
value,negative predictive value & accuracy.
Results: - Our negative appendectomy rate was
19.5% (22.22% for paediatrics 40.9% for females
4.2% for males). MASS showed sensitivity of
61%(92.8% for paediatrics 38% for females & 58%
for males), specificity 80% (75% for paediatrics
88% for females & 50% for males), positive
predictive value 92%(92.8% for paediatrics 83%
for females 50% for males), negative predictive
value 33% (75%for paediatrics 50% for females
5% for males) & accuracy 65% (88.9% for
paediatrics 59% for females 58% for males).
Conclusion:- MASS was of limited help to junior
doctors in our setting,clinical assessment &
experience are still the gold standard for acute
appendicitis.
In this present paper, an experimental study of some plasma characteristics in dielectric barrier discharge (DBD) system using several variables, such as different frequencies and using two different electrodes metals(aluminium (Al) and copper (Cu)), is represented. The discharge plasma was produced by an AC power supply source of 6 and 7 kHz frequencies for the nitrogen gas spectrum and for two different electrodes metals(Al and Cu). Optical emission spectrometer was used to study plasma properties (such as electron temperature ( ), electron number density ( ), Debye length ( ), and plasma frequency ( )). In addition, images were analysed for the plasma emission intensity at atmospheric air pressure.
Pattern matching algorithms are usually used as detecting process in intrusion detection system. The efficiency of these algorithms is affected by the performance of the intrusion detection system which reflects the requirement of a new investigation in this field. Four matching algorithms and a combined of two algorithms, for intrusion detection system based on new DNA encoding, are applied for evaluation of their achievements. These algorithms are Brute-force algorithm, Boyer-Moore algorithm, Horspool algorithm, Knuth-Morris-Pratt algorithm, and the combined of Boyer-Moore algorithm and Knuth–Morris– Pratt algorithm. The performance of the proposed approach is calculated based on the executed time, where these algorithms are applied o
... Show MoreIntrusion detection systems detect attacks inside computers and networks, where the detection of the attacks must be in fast time and high rate. Various methods proposed achieved high detection rate, this was done either by improving the algorithm or hybridizing with another algorithm. However, they are suffering from the time, especially after the improvement of the algorithm and dealing with large traffic data. On the other hand, past researches have been successfully applied to the DNA sequences detection approaches for intrusion detection system; the achieved detection rate results were very low, on other hand, the processing time was fast. Also, feature selection used to reduce the computation and complexity lead to speed up the system
... Show MoreIn this work, optical system with elliptical aperture using point spread function was studied. This is due to its comparison with an optical system with a circular aperture. The present work deals with the theoretical study of intensity distribution within the image. In this work, a special formula was derived which is called the point spread function (PSF) by using a pupil function technique. The work deals with the limited optical system diffraction only (ideal system), and the system with focal shift. Also a graphic relation was founded between eccentricity and the best of focal depth given to at least (80%) of intensity.
Objectives: Evaluation of school health surveillance system with Indicate the level of usefulness of this system,
in addition to Describe the system.
Methodology: A probability multistage sample of (54) subjects which is selected the school health units from
the health institutions. Questionnaire has been divided into three main parts consist, form(A) especially for
health directorate, form (B) for health sectors, and form (C) for primary health care centers; each form contains
the basic components, structure, process, outcome, total items of questionnaire was ( 74) items.
Results: The study results indicate that the system is average adequacy, simple, moderately flexible, highly
acceptance, representative, low utili
In this paper, a mathematical model consisting of the two harmful
phytoplankton interacting with a herbivorous zooplankton is proposed and studied.
The existence of all possible equilibrium points is carried out. The dynamical
behaviors of the model system around biologically feasible equilibrium points are
studied. Suitable Lyapunov functions are used to construct the basins of attractions
of those points. Conditions for which the proposed model persists are established.
The occurrence of local bifurcation and a Hopf bifurcation are investigated. Finally,
to confirm our obtained analytical results and specify the vital parameters, numerical
simulations are used for a hypothetical set of parameter values.
In recent years, encryption technology has been developed rapidly and many image encryption methods have been put forward. The chaos-based image encryption technique is a modern encryption system for images. To encrypt images, it uses random sequence chaos, which is an efficient way to solve the intractable problem of simple and highly protected image encryption. There are, however, some shortcomings in the technique of chaos-based image encryption, such limited accuracy issue. The approach focused on the chaotic system in this paper is to construct a dynamic IP permutation and S-Box substitution by following steps. First of all, use of a new IP table for more diffusion of al
... Show MoreA steganography hides information within other information, such as file, message, picture, or video. A cryptography is the science of converting the information from a readable form to an unreadable form for unauthorized person. The main problem in the stenographic system is embedding in cover-data without providing information that would facilitate its removal. In this research, a method for embedding data into images is suggested which employs least significant bit Steganography (LSB) and ciphering (RSA algorithm) to protect the data. System security will be enhanced by this collaboration between steganography and cryptography.
Palm vein recognition is a one of the most efficient biometric technologies, each individual can be identified through its veins unique characteristics, palm vein acquisition techniques is either contact based or contactless based, as the individual's hand contact or not the peg of the palm imaging device, the needs a contactless palm vein system in modern applications rise tow problems, the pose variations (rotation, scaling and translation transformations) since the imaging device cannot aligned correctly with the surface of the palm, and a delay of matching process especially for large systems, trying to solve these problems. This paper proposed a pose invariant identification system for contactless palm vein which include three main
... Show MoreIn this work, a modern optical system based on modulation technique is constructed to achieve the retrieval of optical defects and distortions of the images behind dark barriers. A 800x600 analog spatial light modulator (SLM) is used in this technique with a 632.8nm He-Ne laser, a circular metallic mesh (CMM) is imaged and disturbed and then dealing with our system. The SLM was confirmed for irregularity improvement such as variable diffracted optical element (DOE) control. The obtained results showed that the effect of distortion has been treated and reduced to be minimum by controlling phase and amplitude modulation of the scattered wave front utilizing the SLM. The obtained images showed identical to the original image wi
... Show More