Background: Laparoscopic surgery for
appendicitis is now a well established and
advanced method of performing general surgical
procedures.
Objectives: To compare the outcome of
laparoscopic and open appendectomies in terms
of operative time, analgesic requirement,
postoperative complications, hospital stay, return
to normal activity and condition of scar.
Methods: This prospective study was carried
out from 1stMay 2008-1st January 2010, involving
110 patients (45 male and 65 female) with
features suggestive of acute appendicitis were
divided into 45 patients laparoscopic
appendectomy (LA) group and 65 patients open
appendectomy (OA) group, after taking informed
consent. LA was done with the help of three
trocars/cannulae creating pneumoperitoneum
with CO2 whereas OA was performed by grid
iron incision.
Results: Forty five patients were assigned to
the laparoscopic appendectomy group and 65
patients were assigned to the open appendectomy
group. Five patients were converted intraoperatively
from laparoscopic appendectomies to
open procedures. The operating times in OA and
LA were 20-110 minutes (mean 30) and 45-120
minutes (mean 55) respectively. Increased doses
of analgesics, antibiotics and antiemetics were
required in OA, as compared to LA. The mean
postoperative hospital stay in LA group was 1
day (range 1-3 days) where as it was; 2.2 days
(range 2-5 days) in OA group.
Conclusion: LA is safe and it has major
benefits like less postoperative pain, decreased
wound infection, early hospital discharge, early
return to work and a better cosmetic scar than
OA
The problem of generated waste as a result of the implementation of construction projects, has been aggravated recently because of construction activity experienced by the world, especially Iraq, which is going through a period of reconstruction, where construction waste represents (20-40%) of the total generated waste and has a negative effect on the environment and economic side of the project. In addition, the rate of consumpted amounts of natural resources are estimated to be about 40% in the construction industry, so it became necessary to reduce waste and to be manage well. This study aims to identify the key factors affecting waste management through the various phases of the project, and this is accom
... Show MoreThe majority of the environmental outputs from gas refineries are oily wastewater. This research reveals a novel combination of response surface methodology and artificial neural network to optimize and model oil content concentration in the oily wastewater. Response surface methodology based on central composite design shows a highly significant linear model with P value <0.0001 and determination coefficient R2 equal to 0.747, R adjusted was 0.706, and R predicted 0.643. In addition from analysis of variance flow highly effective parameters from other and optimization results verification revealed minimum oily content with 8.5 ± 0.7 ppm when initial oil content 991 ppm, tempe
This work includes preparation of Az, Qz, and Tz derivatives from the reaction of Schiff base (Sb) derivative with anthranilic acid, chloroacetyl chloride, and sodium azide, as well as, the characterization via FT-IR, 1H-NMR, and 13CNMR. The anticorrosion inhibition of these compounds was studied and the measurements of carbon steel (CS) corrosion in sodium chloride solution 3.5% (blank) and inhibitor in solutions were calculated at a temperature range of 293-323 K by the technique of electrochemical polarization. In addition, some thermodynamic and kinetic activation parameters for inhibitor and blank solutions (Ea⋇, ΔH⋇, ΔS⋇, and ΔG⋇) were determined. The results showed high inhibition efficacy for all the prepared compounds,
... Show MoreThe electrochemical polymerization of the monomer sulfanilamide (SAM) in an aqueous solution at room temperature produces polysulfanilamide (PSAM). The Fourier Transform Infrared spectroscopy (FTIR) was used to investigate the properties of the prepared polymer layer that generated on the stainless steel (St.S) surface (working electrode) and Atomic Force Microscope (AFM) was used to characterize the morphology, topology, and detailed surface structure of polymer layer that generated on the surface. The corrosion behavior of uncoated and coated St.S were evaluated by using the electrochemical polarization method in a 0.2 M HCl solution and a temperature range of 293–323 K, the anticorrosion action of the polymer coating on stainless steel
... Show MoreBackground In recent years, there has been a notable increase in the level of attention devoted to exploring capabilities of nanoparticles, specifically gold nanoparticles AuNPs, within context of modern times. AuNPs possess distinct biophysical properties, as a novel avenue as an antibacterial agent targeting Streptococcus Mutans and Candida Albicans. The aim of this study to create a nano-platform that has the potential to be environmentally sustainable, in addition to exhibiting exceptional antimicrobial properties against Streptococcus Mutans as well as Candida Albicans. Methods this study involved utilization of
The human gastrointestinal system is a complex ecosystem crucial for well-being. During sepsis-induced gut injury, the integrity of the intestinal barrier can be compromised. Lipopolysaccharide (LPS), an endotoxin from Gram-negative bacteria, disrupts the intestinal barrier, contributing to inflammation and various dysfunctions. The current study explores the protective effects of limonene, a natural compound with diverse biological properties, against LPS-induced jejunal injury in mice. Oral administration of limonene at dosages of 100 and 200 mg/kg was used in the LPS mouse model. The Murine Sepsis Score (MSS) was utilized to evaluate the severity of sepsis, while serum levels of urea and creatinine served as indicators of renal f
... Show MoreUnused and expired pharmaceutical drugs are a novel type of organic corrosion inhibitor. They are less expensive, more effective, and less harmful than conventional organic corrosion inhibitors. This study investigated the effects of concentration, adsorption mechanism and thermodynamic parameters of enalapril malate (ENAP) as a corrosion inhibitor for carbon steel in a saline solution (3.5 % NaCl). The polarization method was used to determine the corrosion rate and inhibition efficiency. Field emission scanning electron microscopy (FE-SEM) and atomic force spectroscopy (AFM) were used to investigate the surface morphology and topography of carbon steel after immersion in both uninhibited and inhibited media for 24 h. Fourier transform inf
... Show More