Background: Excessive crying in early
infancy is a common condition that causes a
great deal of concern to the parents and
physician.
Objective: The aim of this study is to find
the underlying etiology of excessive crying in
infancy and to determine how the history,
physical examination, and laboratory
investigations contribute to the final diagnosis.
Method: A prospective study done on 150
afebrile infants less than 4 months of age
visited Al-Elwia hospital for children
complaining of excessive crying of more than
two hours.
The study done over a one year period from
the first of January 2009 to the end of
December 2009.
All febrile infants and those with acute illness
preceding the onset of crying were excluded
from the study.
Results: Of 150 afebrile infants with
excessive crying 95 cases (63.3%) diagnosed
as having idiopathic colic, 55 cases (36.7%)
have a secondary underlying disorder.
The most common associated disorders
include constipation, 12 cases (8%), gastroesophageal
reflux in 9 cases (6%), and feeding
problems in 9 cases (6%).
Urinary tract infection was the most common
underlying serious etiology found in 4 cases
(2.7%).
History and physical examination contribute to
the final diagnosis in 85% of cases.
Conclusion: Accurate diagnosis of infants
with colic or excessive crying requires a
thorough history and physical examination to
exclude underlying etiology.
Screening laboratory tests apart from urine
analysis and culture is of little help.
Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95
... Show MoreThe reaction oisolated and characterized by elemental analysis (C,H,N) , 1H-NMR, mass spectra and Fourier transform (Ft-IR). The reaction of the (L-AZD) with: [VO(II), Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II)], has been investigated and was isolated as tri nuclear cluster and characterized by: Ft-IR, U. v- Visible, electrical conductivity, magnetic susceptibilities at 25 Co, atomic absorption and molar ratio. Spectroscopic evidence showed that the binding of metal ions were through azide and carbonyl moieties resulting in a six- coordinating metal ions in [Cr (III), Mn (II), Co (II) and Ni (II)]. The Vo (II), Cu (II), Zn (II), Cd (II) and Hg (II) were coordinated through azide group only forming square pyramidal
... Show More