Background: Chronic cough is often the key
symptom not only of chronic pulmonary diseases
but for other important extrapulmonary
pathologies, in particular upper airway and
gastrointestinal diseases.
Objective: This study was designed to
determine the etiology of chronic cough and the
usefulness of the available diagnostic tests in
reaching its causes.
Methods: One hundred patients presenting with
chronic cough at Baghdad Teaching Hospital
Outpatient Clinic were enrolled in this study. The
patients underwent a full clinical interview,
physical examination with indicated diagnostic
test(s) (such as chest x ray, bronchoscope, PFT,
GIT study, sinus X ray or CT).
Results: An etiology of chronic cough was
determined in 93% of the patients. Post nasal drip
is the leading cause of chronic cough reported in
31% of the patient, while asthma gastroesophageal
reflux disease, and chronic bronchitis
seen in (26, 20, and 6 % respectively).
The diagnosis of chronic cough can be reached by
comprehensive history, proper physical
examination, and chest X ray findings in 66 %
patients, further more sophisticated and invasive
tests like: PFT, upper GIT study , expectorated
sputum examination (AFB, Gram staining,
cytology), fibrooptic bronchoscope, and full ENT
evaluation including sinuses X ray or sinuses CT
scanning, are need in the rest.
Conclusion: The etiology of chronic cough can
often be diagnosed safely with a simple initial
evaluation (history, physical examination and
chest X-ray). Postnasal drip, asthma and
gastroesophageal reflux disease account for the
etiology in more than three quarter of the patients.
Using an electrochemical polymerization technique at room temperature, poly nicotine amide (PNA) was produced from the monomer nicotine amide (NA) in aqueous solution. The structure of polymer layer generated on the stainless steel surface (316 L) (working electrode) is investigated by Fourier Transmission Infrared Region (FT-IR). The anti-corrosion activity of polymer coating on the stainless steel (SS 316 L) is investigated by electrochemical polarization in 0.20M solution of HCl at 293-323K. The graphene -modified polymer film-coated SS had greater protection efficiency (PE percent) when compared to Nano ZnO -modified polymer film-coated SS. For the corrosion process of SS 316 L, kinetic and thermo-dynamic parameters of activatio
... Show MoreThis study includes the preparation of the ferrite nanoparticles CuxCe0.3-XNi0.7Fe2O4 (where: x = 0, 0.05, 0.1, 0.15, 0.2, 0.25, 0.3) using the sol-gel (auto combustion) method, and citric acid was used as a fuel for combustion. The results of the tests conducted by X-ray diffraction (XRD), emitting-field scanning electron microscopy (FE-SEM), energy-dispersive X-ray analyzer (EDX), and Vibration Sample Magnetic Device (VSM) showed that the compound has a face-centered cubic structure, and the lattice constant is increased with increasing Cu ion. On the other hand, the compound has apparent porosity and spherical particles, and t
... Show Moresix specimens of the Hg0.5Pb0.5Ba2Ca2Cu3-y
This study was carried out to measure the percentage of heavy metals pollution in the water of the Diyala river and to measure the percentage of contamination of these elements in the leafy vegetables grown on both sides of the Diyala river, which are irrigated by the contaminated river water (celery, radish, lepidium, green onions, beta vulgaris subsp, and malva). Laboratory analysis was achieved to measure the ratio of heavy element contamination (Pb, Fe, Ni, Cd, Zn and Cr) using flame atomic absorption spectrophotometer during the summer months of July and August for the year 2017. The study showed that the elements of zinc, chromium, nickel and cadmium were high concentrations and exceeded. The maximum concentration of these
... Show MoreWe studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show MoreIntroduction: Nitrofurantoin (NFT) is abroad spectrum bactericidal antibiotic. The bioavailability of NFT is affected by many factors. Samafurantin® tablets containing 50 mg NFT were manufactured by Samarra drug industry. Urinary excretion studies were employed since; the urinary tract is the main site of NFT action and excretion. Objective: The objective of the study was to investigate the effect of Uricol® and food on secondary pharmacokinetic parameters of Samafurantin® tablets with different doses by applying urinary data. Methods: Twelve healthy male volunteers participated in this study. Urine samples were collected from each volunteer after overnight fasting at a specified time intervals which considered as a blank sample for meas
... Show More