Background Over the past decade there has been a growing awareness of, and interest in, the trace element concentration differences between normal and diseased tissues. Significant changes in tissue concentrations of Zinc (Zn) and Copper (Cu) have been previously reported in inflammation and cancer of certain human tissues.
Aim:(1)To correlate between Zn and Cu concentrations and the histological picture of normal and certain inflamed human tissues, namely the gall bladder (GB) the vermiform appendix (VA), visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT). (2) to detect whether there is a difference in the above-mentioned parameters between VAT and SAT. (3) to obtain recordings for trace element levels in human tissues.
Methods: Diseased GB (10), VA (10), VAT (10) near these organs and SAT (10) were removed by surgery. Tissues from these organs were then processed for histopathology and analyzed for trace elements concentration by Atomic Absorption Flame-Emission Spectrophotometer.
Results: Zn concentration was high in VAT (0.410 μg/g ± 0.181), GB (0.478 μg/g ±0.531) and VA (0.419 μg/g ±0.123) when compared to its level in SAT (0.1329 μg/g ± 0.0129) and the difference was significant (<0.007,<0.056 and <0.000 respectively).
Cu concentration was high in VAT (0.640 μg/g ± 0.150) and GB (0.919 μg/g ± 0.564) when compared to SAT (0.3893 μg/g ± 0.0130) and the difference was significant (<0.005 and <0.011 respectively). Cu concentration in the VA was low (0.2055 μg/g ±0.0654) and significantly different from all the other tissues (VA vs VAT <0.000, VA vs GB <0.002 and VA vs SAT <0.000).
The histology findings were typical of chronic inflammatory reactions in the GB and of acute inflammation in the VA.
Conclusions: The increase in tissue concentrations of Zn in VAT, GB & VA is due to inflammation.
The high Cu level in chronically inflamed GB and neighboring VAT is due to the increased need for this element during inflammation.
Our results, together with findings reported by others, allow us to think of using trace elements, namely Zn and Cu, as tools for diagnosis and treatment in appropriate conditions.
Objectives This study aimed to compare the clinical effectiveness of four aligning archwires: Superelastic Nickel-Titanium (Superelastic-NiTi), SmartArch, Copper-Nickel-Titanium (Cu-NiTi), and Speed Tubular coaxial-Nickel-Titanium (Tubular coaxial-NiTi), regarding the alignment efficiency, associated perception of pain, and possibility of inducing root resorption.
Materials and Methods This study includes two randomized clinical trials run in parallel. Patients with 5 to 9 mm of mandibular anterior teeth crowding according to Little's irregularity index (LII) who needed fixed orthodontic appliances without extraction were randomly assigned to four groups of
Electrochemical Machining is a term given to one of nontraditional machining that uses a chemical reaction associated with electric current to remove the material. The process is depending on the principle of anodic dissolution theory for evaluating material removal during electrochemical process. In this study, the electrochemical machining was used to remove 1 mm from the length of the a workpiece (stainless steel 316 H) by immersing it in to electrolyte (10, 20 and 30 g) of NaCl and Na2SO4 to every (1 litter of filtered water). The tool used was made from copper. Gap size between the workpiece and electrode is (0.5) mm. This study focuses on the effect of the changing the type and concentration of electroly
... Show MoreIn this study, Laser Shock Peening (LSP) effect on the polymeric composite materials has been investigated experimentally. Polymeric composite materials are widely used because they are easy to fabricate and have many attractive features. Unsaturated polyester resin as a matrix was selected and Aluminum powder with micro particles as a reinforcement material was used with different volume fraction (2.5%, 5% and 7.5%). Hand lay-up process was used for preparation the composites. Fatigue test with constant amplitude with stress ratio (R =-1) was carried out before and after LSP process with two levels of energy (1Joule and 2Joule). The result showed an increase in the endurance strength of 25.448% at 7.5% volume fraction when peened is 1J
... Show MoreAbstract
The catalytic cracking conversion of Iraqi vacuum gas oil was studied on large and medium pore size (HY, HX, ZSM-22 and ZSM-11) of zeolite catalysts. These catalysts were prepared locally and used in the present work. The catalytic conversion performed on a continuous fixed-bed laboratory reaction unit. Experiments were performed in the temperature range of 673 to 823K, pressure range of 3 to 15bar, and LHSV range of 0.5-3h-1. The results show that the catalytic conversion of vacuum gas oil increases with increase in reaction temperature and decreases with increase in LHSV. The catalytic activity for the proposed catalysts arranged in the following order:
HY>H
... Show MoreObjectives: To assess the coping strategies of parents of children with autism and the relationship of
different strategies with their educational level.
Methodology: A descriptive analytical study was carried out from Feb. 14th, 2013 through April, 10th
, 2013 in
several private rehabilitation centers of autism in Baghdad city. A non- probability (purposive) sample of 100
autistic children and 100 of their parents (father or mother) was assessed by a questionnaire which consisted of
two parts; the first part is concerned with the demographic characteristics of the child and demographic
characteristics of the parents; the second part consisted of 50 questions about coping strategies that were
distributed on 8 doma
In this work a hybrid composite materials were prepared containing matrix of polymer (polyethylene PE) reinforced by different reinforcing materials (Alumina powder + Carbon black powder CB + Silica powder). The hybrid composite materials prepared are: • H1 = PE + Al2O3 + CB • H2 = PE + CB + SiO2 • H3 = PE + Al2O3 + CB + SiO2 All samples related to electrical tests were prepared by injection molding process. Mechanical tests include compression with different temperatures and different chemical solutions at different immersion times The mechanical experimentations results were in favour of the samples (H3) with an obvious weakness of the samples (H1) and a decrease of these properties with a rise in temperature and the increasing
... Show MoreStone Matrix Asphalt (SMA) is a gap-graded asphalt concrete hot blend combining high-quality coarse aggregate with a rich asphalt cement content. This blend generates a stable paving combination with a powerful stone-on-stone skeleton that offers excellent durability and routing strength. The objectives of this work are: Studying the durability performance of stone matrix asphalt (SMA) mixture in terms of moisture damage and temperature susceptibility and Discovering the effect of stabilized additive (Fly Ash ) on the performance of stone matrix asphalt (SMA) mixture. In this investigation, the durability of stone matrix asphalt concrete was assessed in terms of temperature susceptibility, resistance to moisture damage, and sensitivity t
... Show More