Background :Evening preparation for colonoscopy is often unsatisfactory and inconvenient. This study was performed to compare the efficacy of bowel preparation at two different timings: night before and morning of endoscopy and to compare the cecal intubation rate and disturbance of sleep hours between these two groups.
Methods: In this prospective randomized endoscopist- blinded trial, 150 patients were enrolled between March 2010 and August 2011. Patients aged between 18 to 80 years needing colonoscopy were included. Patients with prior bowel surgery, suspected bowel obstruction or those who didn't completely fulfill the preparation instructions were excluded. Patients received polyethyelen glycol electrolyte preparation in a morning and evening regimen. Bowel cleansing was scored using the Ottawa Bowel Preparation Quality Scale. Loss of sleep and cecal intubation rate was evaluated.
Results: Seventy five patients received morning regimen and 75 patients received evening regimen.
There was significant difference in total scores of bowel preparation for the two groups favoring the morning group (ρ < 0.0001) . Bowel cleansing for right and mid colon were significantly better in the morning group (ρ < 0.001), while the difference for the left colon was not significant. The cecal intubation rate was comparable for both groups ( ρ NS).Sleep was disturbed in 15 patients in morning group and in 42 patients in evening group (ρ = 0.003).
Conclusion: In conclusion, this study suggests that morning preparation provide better quality of bowel preparation for colonoscopy than evening preparation. Right and mid sided colonic preparation is superior in the patients who take the morning preparation than left sided preparation. Evening preparation is associated with a significant sleep disturbance. This would translate to considerable financial losses and patient discomfort.
S a mples of compact magnesia and alumina were evaporated
using CO2-laser .The
Processed powders were characterized by electron microscopy
and both scanning and transmission electron microscope. The results
indicated that the particle size for both powders have reduced largely
to 0.003 nm and 0.07 nm for MgO and Al2O3, with increasing in
shape sphericity.
Recently, emulgel has emerged as one of the most interesting topical preparations in the field of pharmaceutics. In this research clotrimazole was formulated as topically applied emulgel ; different formulas were prepared. The prepared emulgels were evaluated for their physical appearance , rheological behaviour , and in vitro drug release . The influence of the type of gelling agent (carbopol 934 and methyl cellulose), the concentration of both the emulsifying agent (2% and 4% w/w of mixture of span 20 and tween 20) and the oil phase (5% and 7.5% w/w of liquid paraffin) and the type of oil phase (liquid paraffin and cetyl alcohol), on the drug release from the prepared emulgels was invest
... Show MoreDiamond-like carbon, amorphous hydrogenated films forms of carbon, were pretreated from cyclohexane (C6H12) liquid using plasma jet which operates with alternating voltage 7.5kv and frequency 28kHz. The plasma Separates molecules of cyclohexane and Transform it into carbon nanoparticles. The effect of argon flow rate (0.5, 1 and 1.5 L/min) on the optical and chemical bonding properties of the films were investigated. These films were characterized by UV-Visible spectrophotometer, X-ray diffractometer (XRD) Raman spectroscopy and scanning electron microscopy (SEM). The main absorption appears around 296, 299 and 309nm at the three flow rate of argon gas. The value of the optical energy gap is 3.37, 3.55 and 3.68 eV at a different flow rate o
... Show MoreIn this work preparation of antireflection coating with single layer of MgO using pulsed laser deposition (PLD) method which deposit on glass substrate with different thicknesses (90 and 100) nm annealed at temperature 500 K was done.
The optical and structural properties (X-ray diffraction) have been determined. The optical reflectance was computed with the aid of MATLAB over the visible and near infrared region. Results shows that the best result obtained for optical performance of AR'Cs at 700 shots with thickness 90 nm nanostructure single layer AR'Cs and low reflection at wavelength 550 nm.
In this paper, we will study non parametric model when the response variable have missing data (non response) in observations it under missing mechanisms MCAR, then we suggest Kernel-Based Non-Parametric Single-Imputation instead of missing value and compare it with Nearest Neighbor Imputation by using the simulation about some difference models and with difference cases as the sample size, variance and rate of missing data.
Countries are developing the spatial development of their societies through the projects that they undertake in various ways, and this development may be cause great impact on the environment, which also depend on the type of development, whether industrial, agricultural, or service and after the problems that occurred as a result of development on the environment, most of the countries currently did to legislating laws Environmental and some other procedures before granting environmental approvals for the purpose of establishing spatial development projects. One of the most important of these laws and regulations is Environmental impact assessment (EIA). The environmental impact asse
The liver (hepatic) is one of the largest glands or organs of the digestive system in the body of living organisms, including rodents, take the squirrel in this study for example. The study and the collection of sources emerged to be put into the hands of those, especially those interested in histological studies, including junior or professionals and veterinarians, knowledge of the stains used in the research and their final results.
In this study, the sonochemical degradation of phenol in water was investigated using two types of ultrasonic wave generators; 20 kHz ultrasonic processor and 40 kHz ultrasonic cleaner bath. Mineralization rates were determined as a function of phenol concentration, contact time, pH, power density, and type of ultrasonic generator. Results revealed that sonochemical degradation of the phenol conversion was enhanced at increased applied power densities and acidic conditions. At 10 mg/L initial concentration of phenol, pH 7, and applied power density of 3000 W/L, the maximum removal efficiency of phenol was 93% using ultrasonic processor at 2h contact time. Whereby, it was 87% using and ultrasonic cleaner bath at 16h contact time and 150 W
... Show More