Background; Perforated duodenal ulcer (PDU) is a common surgical emergency that is associated with high mortality and morbidity. Early diagnosis and prompt surgical treatment is required to prevent grave complications.
Objective; The study was designed to evaluate the diagnostic accuracy of different radiological investigations in the diagnosis of perforated duodenal ulcer.
Methods; A prospective study of 185 pts with PDU at al kindy teaching hospital, Baghdad, Iraq from June 2008- august 2010. patients were examined clinically and investigated by blood test, chest x ray, plain X ray of the abdomen. Ultrasonography (U/S) and CT scanning done for those patients with negative X- ray finding. Resuscitation by intravenous fluid and antibiotic done. Explorative laparotomy done for all patients, repair of perforation done by simple omental patch. Data regarding radiological, ultrasonographic and CT finding and operative finding were recorded.
Results: The study of 185 pts with proven perforated DU revealed 162 (87.5%) male and 23 (12.5%) female with age ranging from 22-70 yrs ,the average was 38 years.
Crescentic shape air under diaphragm was seen in chest or abdominal plain X ray in 121 (65.4%) pts and negative in 64 (34.6%) pts. For those 64 pts, a positive finding of free air or fluid was seen by U/S in 16 (25%) pts and positive CT finding was seen in 62 (96.9%) pts.
The operative finding in those 64 pts were; a small perforation less than 0.5 cm in 24 pts, completely or partially sealed perforation in 19 pts, severe edema and narrowing of the pylorus in 15 pts and perforation larger than 1 cm but with little peritoneal soiling was seen in 6 pts.
Conclusions: Pneumoperitonium was detected radiologically in 65% of pts of perforated DU. CT scan was found to be superior to U/S study for the diagnosis in pts with negative X-ray finding. For pts with perforated DU Conservative treatmentcan be adopted in pts with negative radiological findings.
In this paper, we made comparison among different parametric ,nonparametric and semiparametric estimators for partial linear regression model users parametric represented by ols and nonparametric methods represented by cubic smoothing spline estimator and Nadaraya-Watson estimator, we study three nonparametric regression models and samples sizes n=40,60,100,variances used σ2=0.5,1,1.5 the results for the first model show that N.W estimator for partial linear regression model(PLM) is the best followed the cubic smoothing spline estimator for (PLM),and the results of the second and the third model show that the best estimator is C.S.S.followed by N.W estimator for (PLM) ,the
... Show MoreThe aim of this work is to evaluate the onc-electron expectation values < r > from the radial electronic density funetion D(r) for different wave ?'unctions for the 2s state of Li atom. The wave functions used were published in 1963,174? and 1993 , respectavily. Using " " ' wave function as a Slater determinant has used the positioning technique for the analysis open shell system of Li (Is2 2s) State.
In this research, a numerical simulation was conducted to study the behavior of the scouring pattern and the effect of spacing between bridge piers at specified hydraulic conditions such as velocity, depth of flow, and the sediment effective diameter. Moreover, the cross-section shape of piers and their effect on the scouring depth around bridge piers was studied, using Computational Fluid Dynamics (CFD), ANSYS (Fluent) software. A comparison of the simulation results obtained with previous laboratory investigations was done to verify the validity of the numerical model. Generally, the scour pattern using the CFD software gave good agreement with the experimental study. A reversed pro
Background: Elastomeric chains are one of the most commonly used force delivery systems. They have the ability to exert a continuous force, convenience of use, compatibility to oral environment and cost effectiveness but one of the inherited disadvantages is force degradation. Materials and methods: This in vitro study was designed to evaluate the effect of alcohol presence in mouthwashes on force decay of different configurations of clear elastomeric chains from (Ortho Technology company) which are: closed , short and long under the effect of time at (Initial, 1, 2, 3 and 4 weeks) intervals with exposure to different chemical solutions. A total (540) modules of elastomeric chains of three different types (long, short and closed) trans
... Show Moreجريت التجربة في اصص فخارية سعة كل اصيص 4 كغم تربة في البيت الزجاجي التابع لقسم علوم الحياة/كلية التربية ابن الهيثـــــــــم/جـامعــة بـغداد لموســم النمـو 2008-2009 لدراســة تأثيــر اربعـــة مستويـــــات من سمــــاد اليوريـــا وهي (0, 0.1, 0.2, 0.4) غم/اصيص والتي تعادل (0, 100, 200, 400) كغم/هكتار وثلاث مستويات من سماد السوبر فوسفات وهي (0, 0.1, 0.2) غم/اصيص والتي تعادل (0, 100, 200) كغم/هكتارفي مكونـات الحاصـــل لنبــات الحلبـــة Trigonella foe
... Show MoreHepatocellular carcinoma (HCC) is the third most common cause of cancer-related death. Therefore, it is critical for researchers to understand molecular biology in greater depth. In several diseases including cancer, abnormal miRNA expression has been linked to apoptosis, proliferation, differentiation, and metastasis. Many miRNAs have been studied in relation to cancer, including miR-122, miR-223, and others. Hepatitis B and C viruses are the most important global risk factors for HCC. This study is intended to test whether serum miRNAs serve as a potential biomarker for both HCC and viral infections HBV and C. The expression of miRNA in 64 serum samples was analyzed by RT-qPCR. Compared to healthy volunteers, HCC patients' sera expre
... Show MoreIn light of the development in computer science and modern technologies, the impersonation crime rate has increased. Consequently, face recognition technology and biometric systems have been employed for security purposes in a variety of applications including human-computer interaction, surveillance systems, etc. Building an advanced sophisticated model to tackle impersonation-related crimes is essential. This study proposes classification Machine Learning (ML) and Deep Learning (DL) models, utilizing Viola-Jones, Linear Discriminant Analysis (LDA), Mutual Information (MI), and Analysis of Variance (ANOVA) techniques. The two proposed facial classification systems are J48 with LDA feature extraction method as input, and a one-dimen
... Show MoreIn this work, the effects of size, and temperature on the linear and nonlinear optical properties in InGaN/GaN inverse parabolic and triangular quantum wells (IPQW and ITQW) for different concentrations at the well center were theoretically investigated. The indium concentrations at the barriers were fixed to be always xmax = 0.2. The energy levels and their associated wave functions are computed within the effective mass approximation. The expressions of optical properties are obtained analytically by using the compact density-matrix approach. The linear, nonlinear, and total absorption coefficients depending on the In concentrations at the well center are investigated as a function of the incident photon energy for different
... Show MoreBackground: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For e
... Show MoreBackground and objectives: This study aimed at testing the effect of plastic sleeve or barrier, used to cover the guide of the light cure unit to prevent cross-infection, on the shear bond strength and site of bond failure of stainless steel and ceramic orthodontic brackets. Materials and methods: Forty orthodontic brackets; twenty stainless steel and twenty ceramic brackets bonded to forty extracted human maxillary first premolars using light cure adhesive cured with and without the use of a protective plastic barrier on the guide. Comparing the effect of this barrier on the shear bond strength and adhesive remnant index was performed using an independent t-test and Chi-square test. Results: The protective barrier had decreased the shear b
... Show More