Objective: To compare the efficacy and safety of isosorbide mononitrate (IMN) versus misoprostol used to induce labour for overdue pregnancy.
Setting: A prospective randomized clinical study conducted at AL-Elwiya Maternity Teaching Hospital in Baghdad from Jan. 2008 to Dec. 2008.
Method: One hundred and fifty women with over due pregnancy (past date and posterm pregnancy) referred for induction of labour with Bishop scores <_ 5 were randomly allocated to receive either forty mg isosorbide mononitrate (IMN) tablet as a single vaginal dose (n=75) or fifty mcg misoprostol vaginally (n=75) every six hrs for a maximum of three doses. Amniotomy and/or oxytocin infusion is considered when Bishop scores frankly progressed (augmentation) or used when no improvement achieved after 24 hour (induction). Adverse effects of medications, induction - delivery interval, mode of delivery and neonatal outcome were recorded and subjected to statistical analysis.
Results: Isosorbide mononitrate was associated with less adverse effects than misoprostol especially regarding uterine tachysystol (0 with isosorbide mononitrate vs 12% with misoprostol, P<0.01) and hyperstimulation (0 with isosorbide mononitrate vs 16% with misoprostol, p<0.01) but the induction - delivery interval with isosorbide mononitrate group was significantly longer compared with misoprostol (26.3±7.3hrs vs 15.4±5.4 hrs , p<0.01). Oxytocin was added to 70 women (93.3%) used isosorbide mononitrate while to 15 women (20%) used misoprostol (p<0.001). Caesarean rate was not significantly different between the two groups, but the indications were different, dystocia is the major cause (73.3%) with isosorbide mononitrate while persistent non-assuring fetal heart rate pattern (64%) in the misoprostol group.
Conclusion: Cervical ripening and induction of labour using isosorbide mononitrate resulted in fewer adverse effects but it was less effective than misoprostol.
Copper selenide (Cu2Se) thin films were prepared by thermal evaporation at RT with thickness 500 nm. The heat-treating for (400 &500) K for the absorber layer has been investigated. This research includes, studying the structural properties of X-ray diffraction (XRD) that show the Cu2Se thin film (Cubic) and has a polycrystalline orientation prevalent (220). Moreover, studying the effect of annealing on their surface morphology properties by using Atomic Force Microscopy AFM. Optical properties were considered using the transmittance and absorbance spectra had been recorded when wavelength range (400 - 1000) nm in order to study the absorption coefficient and energy gap. It was found that these films had allowed direct transitio
... Show MoreThe global food supply heavily depends on utilizing fertilizers to meet production goals. The adverse impacts of traditional fertilization practices on the environment have necessitated the exploration of new alternatives in the form of smart fertilizer technologies (SFTs). This review seeks to categorize SFTs, which are slow and controlled-release Fertilizers (SCRFs), nano fertilizers, and biological fertilizers, and describes their operational principles. It examines the environmental implications of conventional fertilizers and outlines the attributes of SFTs that effectively address these concerns. The findings demonstrate a pronounced environmental advantage of SFTs, including enhanced crop yields, minimized nutrient loss, improved nut
... Show MoreThe using of the parametric models and the subsequent estimation methods require the presence of many of the primary conditions to be met by those models to represent the population under study adequately, these prompting researchers to search for more flexible models of parametric models and these models were nonparametric models.
In this manuscript were compared to the so-called Nadaraya-Watson estimator in two cases (use of fixed bandwidth and variable) through simulation with different models and samples sizes. Through simulation experiments and the results showed that for the first and second models preferred NW with fixed bandwidth fo
... Show MoreSegmentation of urban features is considered a major research challenge in the fields of photogrammetry and remote sensing. However, the dense datasets now readily available through airborne laser scanning (ALS) offer increased potential for 3D object segmentation. Such potential is further augmented by the availability of full-waveform (FWF) ALS data. FWF ALS has demonstrated enhanced performance in segmentation and classification through the additional physical observables which can be provided alongside standard geometric information. However, use of FWF information is not recommended without prior radiometric calibration, taking into account all parameters affecting the backscatter energy. This paper reports the implementation o
... Show MoreThis paper proposes a novel method for generating True Random Numbers (TRNs) using electromechanical switches. The proposed generator is implemented using an FPGA board. The system utilizes the phenomenon of electromechanical switch bounce to produce a randomly fluctuated signal that is used to trigger a counter to generate a binary random number. Compared to other true random number generation methods, the proposed approach features a high degree of randomness using a simple circuit that can be easily built using off-the-shelf components. The proposed system is implemented using a commercial relay circuit connected to an FPGA board that is used to process and record the generated random sequences. Applying statistical testing on the exp
... Show MoreABSTRACT Planetary Nebulae (PN) distances represent the fundamental parameter for the determination the physical properties of the central star of PN. In this paper the distances scale to Planetary Nebulae in the Galactic bulge were calculated re- lated to previous distances scales. The proposed distance scale was done by recalibrated the previous distance scale technique CKS/D82. This scale limited for nearby PN (D ≤ 3.5 kpc), so the surface fluxes less than other distance scales. With these criteria the results showed that the proposed distance scale is more accurate than other scales related to the observations for adopted sample of PN distances, also the limit of ionized radius (Rio) for all both optically thick and optically thin in
... Show More