Background: Prelabour rupture of membranes is a problem that faces the obstetricians. It has many maternal and fetal sequale and its etiology and management still controversial.
Objective: To test the absolute nucleated red blood cells counts at birth in infants who are born after prelabour rupture of membranes.
Methods: A prospective study conducted in AL-Kadhymia Teaching Hospital. Hundred pregnant women were included in this study. Fifty pregnant women who had prelabour rupture of membranes considered as group (1), other fifty pregnant women with intact membranes considered as group (2) through a period of one year. Nucleated red blood cell counts of venous cord blood obtained within one hour of life from 50 infants who were born after prelabour rupture of membranes. The same procedure was applied for the control group.
Results: The nucleated red blood cell counts and Haematocrit were significantly higher in infants who were born after prelabour rupture of membrane than in the control group (P value <0.001 and 0.03 respectively).
Conclusion: Infants born after prelabour rupture of membrane have higher nucleated red blood cell counts at birth than the control group.
In the present work effect of recycled heating and cooling on the values of concrete compressive strength due to high temperature of 4000C was studied.
The tests show that the percent of reduction in compressive strength of the samples which exposed to a temperature of 4000C for one cycle was 32.5%, while the reduction was 52.7% for the samples which were exposed to recycled heating and cooling of ten times .
Moreover a study of the effect of specimen sizes on the percentages of compressive strength reduction due to high temperature
... Show MoreIn this study, an analysis of re-using the JPEG lossy algorithm on the quality of satellite imagery is presented. The standard JPEG compression algorithm is adopted and applied using Irfan view program, the rang of JPEG quality that used is 50-100.Depending on the calculated satellite image quality variation, the maximum number of the re-use of the JPEG lossy algorithm adopted in this study is 50 times. The image quality degradation to the JPEG quality factor and the number of re-use of the JPEG algorithm to store the satellite image is analyzed.
The development in the field of medical physics has led to the use of devices that
are manufactured under normal conditions to make tremendous progress in the
world of development in medical treatment by using these devices with modern
techniques by reducing the use of antibiotics and relying on these tools and devices
that link between physics and modern therapeutic medicine. In this research, a nonthermal
plasma system for argon gas operated at normal atmospheric pressure was
designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated
from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed
to this system, the results showed that these bacteria were killed at time (5 min)
In this paper some perturbations of a satellite orbit with heights more than 10000 km are studied. The two perturbations are due to the presence of other gravitational bodies such as Moon as a conservative perturbing forces and from the non-conservative perturbing forces such as SRP for satellite with A=5.1 m2 and m=900 kg. The position, velocity and momentum components are calculated for the perturbed equation of motion at any instant of time and thus calculate the orbital elements of each perturbation. The orbital elements for the perturbed orbit will deviate from initial elements with time. The equations of motion solved numerically using the fourth order of Runge Kutta method. The results show that the secular variation for orbital e
... Show MoreEthanol production were evaluated by many strains with varing
degree of flocculation in fermentation medium of date extract withl 0
Brix, PHS in 30C0آ آ for آ 48hr.lt was found that ethanol production decrease with increase of flocculation degree and non-flocculant strain is آ more efficient in آ producing ethanol from flocculant strain,then
ethanol sensitivity were examined for the same strains, in liquid medium YE, it was found thatآ آ strain is more sensitive from nonآ flocculant and ethanol sensitivity depends upon flocculation degree.
The present work studies the mechanical properties of SiO2 μPs, and NPs in St/PVA blends. The samples were prepared by casting method as PVA, St/PVA blends at different concentrations (30, 40, 50, and 60 %). DSC and TGA tests were carried out to the samples evolved. The result showed a single glass transition temperature (Tg) for all St /PVA blends that was attributed to the good miscibility of the blends involved. It was found that (Tg) decrease with starch ratio increase. It was seen that (PVA) of (Tg=105 oC); The glass transition temperature which was decrease with starch ratio that was attributed to glass transition relaxation process due to micro-Brownian motion of the main chain back bond. The endothermic peak at 200 oC was attrib
... Show MoreIn this work we fabrication holographic optical element diffraction grating thickness 40?m and mirror90?m by using dichromated gelatin,to perform that we have to use the Nd-yaG laser doubling frequency of wavelenght (532)nm and its powers of (80)mWatt.we have studyed the thickness and concentration dichromat effect in mirror reflaction ,effect of angle of reconstruction beam in band width and diffraction efficiency ,study effect gelatin hardener of the diffraction efficiency.
The study aimed to compare the expression of miR-126-3p and miR-423-5p in patients and normal subjects, and correlate their expression with response to induction therapy. Circulating miR-126-3p and miR-423-5p were measured in the plasma of 43 adult AML patients and 35 age- and sex-matched controls by real time PCR. The foldchange in differential expression for each gene was calculated using the comparative cycle threshold (CT) method (also known as the 2−CT method). For statistical purposes, the fold change was calculated using DDCT (or 2–∆∆Ct) method to find the relative expression of miRNAs. The expression fold change of miR-126-3p was 1.73-fold increase in patients than controls (p= 0.010). The expression fold change of miR-423-5
... Show More