Preferred Language
Articles
/
jkmc-613
The Effect of Prelabour Rupture of Membranes on Circulating Neonatal Nucleated Red Blood Cells
...Show More Authors

 Background: Prelabour rupture of membranes is a problem that faces the obstetricians. It has many maternal and fetal sequale and its etiology and management still controversial.
Objective: To test the absolute nucleated red blood cells counts at birth in infants who are born after prelabour rupture of membranes.
Methods: A prospective study conducted in AL-Kadhymia Teaching Hospital. Hundred pregnant women were included in this study. Fifty pregnant women who had prelabour rupture of membranes considered as group (1), other fifty pregnant women with intact membranes considered as group (2) through a period of one year. Nucleated red blood cell counts of venous cord blood obtained within one hour of life from 50 infants who were born after prelabour rupture of membranes. The same procedure was applied for the control group.
Results: The nucleated red blood cell counts and Haematocrit were significantly higher in infants who were born after prelabour rupture of membrane than in the control group (P value <0.001 and 0.03 respectively).
Conclusion: Infants born after prelabour rupture of membrane have higher nucleated red blood cell counts at birth than the control group.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 02 2018
Journal Name
International Journal Of Science And Research
Mathematical Modelling of Zinc Removal from Wastewater by Using Nanofiltration and Reverse Osmosis Membranes
...Show More Authors

The present work aimed to study the efficiency of nanofiltration (NF) and reverse osmosis (RO) process for treatment of heavy metals wastewater contains zinc. In this research, the salt of heavy metals were zinc chloride (ZnCl2) used as feed solution.Nanofiltration and reverse osmosis membranes are made from polyamide as spiral wound module. The parameters studied were: operating time (0 – 70 min), feed concentrations for zinc ions (10 – 300 mg/l), operating pressure (1 – 4 bar).The theoretical results showed, flux of water through membrane decline from 19 to 10.85 LMH with time. Flux decrease from 25.84 to 10.88 LMH with the increment of feed concentration. The raise of pressure, the flux increase for NF and RO membranes.The maximum

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Mefenamic Acid Selective Membranes Sensor and Its Application to pharmaceutical Analysis
...Show More Authors

PVC membrane sensor for the selective determination of Mefenamic acid (MFA) was constructed. The sensor is based on ion association of MFA with Dodecaphospho molybdic acid (PMA) and Dodeca–Tungstophosphoric acid(PTA) as ion pairs. Nitro benzene (NB) and di-butyl phthalate (DBPH) were used as plasticizing agents in PVC matrix membranes. The specification of sensor based on PMA showed a linear response of a concentration range 1.0 × 10–2 –1.0 × 10–5 M, Nernstian slopes of 17.1-18.86 mV/ decade, detection limit of 7 × 10-5 -9.5 × 10 -7M, pH range 3 – 8 , with correlation coefficients lying between 0.9992 and 0.9976, respectively. By using the ionphore based on PTA gives a concentration range of 1.0 × 10–4 –1.0 × 10–5 M,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 07 2021
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
Relationship of Low Maternal Vitamin D3 Level and Adverse Early Neonatal Outcomes
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Infocommunications Journal
On the Performance of Metamaterial based Printed Circuit Antenna for Blood Glucose Level Sensing Applications: A Case Study
...Show More Authors

Due to the urgent need to develop technologies for continuous glucose monitoring in diabetes individuals, poten tial research has been applied by invoking the microwave tech niques. Therefore, this work presents a novel technique based on a single port microwave circuit, antenna structure, based on Metamaterial (MTM) transmission line defected patch for sensing the blood glucose level in noninvasive process. For that, the proposed antenna is invoked to measure the blood glu cose through the field leakages penetrated to the human blood through the skin. The proposed sensor is constructed from a closed loop connected to an interdigital capacitor to magnify the electric field fringing at the patch center. The proposed an tenna sensor i

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Fri Jan 26 2024
Journal Name
Iraqi Journal Of Science
Prevalence of Toxoplasmosis of Males Blood Donors in Baghdad
...Show More Authors

Toxoplasma gondii is intracellular parasites, which infect a large proportion of the world's population, but uncommonly causes clinically significant disease .The present study was performed to estimate the prevalence of toxoplasmosis in Iraqi male. Venous blood samples were collected from healthy male age between (18-57) years attended the National blood transfusion centre in Baghdad from Oct, 2011 to Jan. 2012. Latex agglutination test (LAT) and Enzyme linked Immunosorbant Assay (ELISA), were used to detect anti-Toxoplasmosis IgM and IgG antibodies. The results showed significant differences between seropositive toxoplasmosis infections between LAT, 136/400 (34%) and ELISA - IgG, 121/400 (30.25%). The blood group phenotypes of the infe

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 05 2024
Journal Name
The Journal Of Obstetrics And Gynecology Of India
Obstetric and Neonatal Outcomes in Overweight Adolescent Pregnant Mothers
...Show More Authors

Background The escalating global concern over increased body weight in adolescents, coupled with the rising rates of adolescent pregnancy worldwide, presents a significant challenge to healthcare systems. We plan to identify the maternal and neonatal consequences associated with pre-pregnancy overweight in adolescent women. Methods Throughout five years, all singleton adolescent pregnant women with pre-pregnancy self-reported body mass index (BMI) of 18.5– ≤ 29.9 were involved during the first-trimester visit. Two groups were generated: overweight and appropriate-weight (BMI 25–29.9 and 18.5–24.9, respectively). Obstetric and neonatal outcomes were observed prospectively and statistically adjusted for the confounding factors.

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Mar 05 2024
Journal Name
The Journal Of Obstetrics And Gynecology Of India
Obstetric and Neonatal Outcomes in Overweight Adolescent Pregnant Mothers
...Show More Authors

Background The escalating global concern over increased body weight in adolescents, coupled with the rising rates of adolescent pregnancy worldwide, presents a significant challenge to healthcare systems. We plan to identify the maternal and neonatal consequences associated with pre-pregnancy overweight in adolescent women. Methods Throughout five years, all singleton adolescent pregnant women with pre-pregnancy self-reported body mass index (BMI) of 18.5– ≤ 29.9 were involved during the first-trimester visit. Two groups were generated: overweight and appropriate-weight (BMI 25–29.9 and 18.5–24.9, respectively). Obstetric and neonatal outcomes were observed prospectively and statistically adjusted for the confounding factors.

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Mar 10 2020
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Maternal Anemia Prevalence and Subsequent Neonatal Complications in Iraq
...Show More Authors

BACKGROUND: Anemia during pregnancy is still a challenge throughout the world, and it may cause severe health consequences in the maternal and fetal sides. AIM: This study aims to find out the prevalence of maternal anemia and potential adverse outcomes in Iraq. METHODS: In Medical City Tertiary Center in Baghdad, singleton pregnant ladies came for delivery were involved over 6 months’ period. Based on hemoglobin (Hb) readings; they were divided into no anemia group (Hb>11 g/l) and anemia group which were further subdivided into mild, moderate, and severe (Hb =10–10.9, =7.1–9.9, and <7 g/l, respectively). Full history and examination were performed by attending obstetrician and pediatrician for the upcoming b

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (5)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Preparing New Ceramic Membranes from Syrian Zeolite Coated with Silver Nanoparticles to Treatment Wells Water
...Show More Authors

As a result of the exacerbation of the problem of water pollution, research was directed towards studying the treatment using ceramic membranes, which proved to be highly effective in treating all water sources. The research aims to study the possibility of preparing a new type of ceramic membranes from Syrian zeolite that was not previously used in this field. In this research, ceramic membranes were prepared from Syrian raw zeolite in several stages. Zeolite sample was characterized, grinded, mixed with boric acid, pressed to form desks, treated thermally according to experiment program, finally coated with silver nanoparticles. Specifications of prepared membranes were determined according to reference methods, effectiveness of prepar

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparison Study for The Performance of Polyethersulfone Ultrafiltration Mixed Matrix Membranes in The Removal of Heavy Metal Ions from Aqueous Solutions
...Show More Authors

Polyethersulfone (PES) ultrafiltration membrane blending NaX zeolite crystals as a hydrophilic additive was examined for zinc (II) and lead ions Pb (II) removal from aqueous solutions. The effect of NaX zeolite content on the permeation flux and removal efficiency was studied. The results showed that adding zeolite to the polymer matrix enhanced the permeation flux. The permeation flux of all the zeolite/PES matrix membranes was higher than the pristine membrane. No significant improvement was observed in the removal of Zn (II) ions using all prepared membranes as the removal percentage did not raise above 29.2%. However, the removal percentage of Pb (II) ions was enhanced to 97% using a membrane containing 0.9%wt. zeolite. Also, it was

... Show More
View Publication Preview PDF
Crossref (6)
Crossref