Background: Direct measurement of intracellular magnesium using erythrocytes has been suggested as a sensitive indicator for the estimation of body magnesium store. Marked depletion in plasma and erythrocyte magnesium levels was particularly evident in diabetic patients with advanced retinopathy and poor diabetic control. While insulin has been shown to stimulate erythrocyte magnesium uptake, hyperglycemia per se suppressed intracellular magnesium in normal human red cells.
Aim of the study: To investigate the erythrocyte magnesium level in Iraqi type I and II diabetic patients, with specific emphasis on the effect of both, metabolic control and the type of antidiabetic treatments.
Methods: Sixty two diabetic patients (7 with type I and 55 with type II diabetes mellitus) recruited from the outpatient diabetes clinic at the Specialized Center For Endocrine Diseases-Baghdad, during the period from 1st October 2005 to 28th February 2006. Eighteen non-diabetic normomagnesemic healthy controls matched for age and sex were participated in this study. Of the diabetics, 22 were using insulin (7 with type I and 15 with type II diabetes mellitus), 40 were taking oral antidiabetic agents (All with type II diabetes mellitus) and none were using both. Serum and erythrocyte magnesium concentration were measured for both groups, and Glycated hemoglobin levels were estimated only for diabetics.
Results : Mean serum and erythrocyte magnesium levels were significantly (p<0.001) lower in the diabetic group as compared to controls. Serum level of magnesium was not a significant predictor of erythrocyte magnesium concentration. No significant correlation was observed between HbA1c and erythrocyte magnesium. Significantly (p<0.001) lower serum magnesium levels were consistently evident through the entire diabetic subgroups as compared to controls. Erythrocyte magnesium contents were significantly (p<0.001) reduced in patients with type I , type II and type II receiving oral antidiabetic agents, but not in patients with type II receiving insulin (p= 0.120 ), as compared to controls. Significant difference in erythrocyte magnesium levels was observed between patients with type II receiving oral antidiabetic agents and those receiving insulin (p<0.001). The frequency of magnesium deficiency in diabetic patients, as judged by a lower serum magnesium reference limit was constantly 100% in all subgroups. While, judgments based upon a lower erythrocyte magnesium reference limit, discloses variable frequencies in diabetic subgroups.
conclusion: The near normal erythrocyte magnesium levels in type II insulin-receiving patients, could be credited to the stimulatory action of exogenous insulin on cellular magnesium uptake and may indicate a possible role of insulin treatment as a potential implications on health policy, by ameliorating cellular magnesium depletion in the continuously expanding diabetic population.
Nuclear emission rates for nucleon-induced reactions are theoretically calculated based on the one-component exciton model that uses state density with non-Equidistance Spacing Model (non-ESM). Fair comparison is made from different state density values that assumed various degrees of approximation formulae, beside the zeroth-order formula corresponding to the ESM. Calculations were made for 96Mo nucleus subjected to (N,N) reaction at Emax=50 MeV. The results showed that the non-ESM treatment for the state density will significantly improve the emission rates calculated for various exciton configurations. Three terms might suffice a proper calculation, but the results kept changing even for ten terms. However, five terms is found to give
... Show MoreAbstract
This work involves studying the effect of adding some selective organic component mixture on corrosion behavior of pure Al and its alloys in condensed synthetic automotive solution (CSAS) at room temperature. This mixture indicates the increasing of octane number in previous study and in this study show the increasing in corrosion resistance through the decreasing in corrosion rate values.
Electrochemical measurements were carried out by potentiostat at 3 mV/sec to estimate the corrosion parameters using Tafel extrapolation method, in addition to cyclic polarization test to know the pitting susceptibility of materials in tested medium.
The cathodic Tafel slope
... Show MoreThis article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while
... Show MoreEco-friendly concrete is produced using the waste of many industries. It reduces the fears concerning energy utilization, raw materials, and mass-produced cost of common concrete. Several stress-strain models documented in the literature can be utilized to estimate the ultimate strength of concrete components reinforced with fibers. Unfortunately, there is a lack of data on how non-metallic fibers, such as polypropylene (PP), affect the properties of concrete, especially eco-friendly concrete. This study presents a novel approach to modeling the stress-strain behavior of eco-friendly polypropylene fiber-reinforced concrete (PFRC) using meta-heuristic particle swarm optimization (PSO) employing 26 PFRC various mixtures. The cement was partia
... Show MoreThis paper is concerned with finding solutions to free-boundary inverse coefficient problems. Mathematically, we handle a one-dimensional non-homogeneous heat equation subject to initial and boundary conditions as well as non-localized integral observations of zeroth and first-order heat momentum. The direct problem is solved for the temperature distribution and the non-localized integral measurements using the Crank–Nicolson finite difference method. The inverse problem is solved by simultaneously finding the temperature distribution, the time-dependent free-boundary function indicating the location of the moving interface, and the time-wise thermal diffusivity or advection velocities. We reformulate the inverse problem as a non-
... Show MoreAbstract The present study on the prevalence of intestinal parasitic infection from July 2003 to July 2004 ,was conducted among children aged(less than 5 -14 )years attending AL-Daura Health Centre in Baghdad City .(350) specimen were choosen randomly and examined, 160(45.7%) of these were infected , 140 (87.5%) harboured one parasite while 20 (12.5%) harboured more than one parasite.190 (54.3%) were non infected with any of intestinal parasite . It was observed that the most common intestinal protozoa among children is Giardia lamblia, followed by Entamoeba histolytica and Blastocystis hominis with pre
In this work, pure and Ag-doped nickel oxide (NiO) thin films were deposited on glass substrates with different dopant concentrations (0.1, 0.2, 0.3 and 0.4 wt.%) by pulsed-laser deposition (PLD) technique at room temperature. These films were annealed at temperature of 450 °C. The structural and optical properties of the prepared thin films were studied. It was found that annealing process has lead to increase the transmittance of the deposited films. Also, the transmittance was found to increase with doping concentration of silver in the deposited NiO films. The optical energy gap was decreased from 3.5 to 3.2 eV as the doping concentration was increased to 0.4 %.
In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm−2), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re