Introduction: The association between acute stroke and
renal function is well known. The aim of this study is to
know which group of patients with acute stroke is more
likely to have undiagnosed Chronic Kidney Disease and
which risk factors are more likely to be associated with.
Methods:We studied 77 patients who were diagnosed to
have an acute stroke.Patients were selected between
April2011andJune 2011 using the " 4-variable
Modification of
Diet in Renal Disease Formula " which estimates
Glomerular Filtration Rate using four variables :serum
creatinine ,age ,race and gender.
Results :The study included 38 male and 39 females
patients ,aged (35-95) years. Glomerular Filtration Rate in
patients with acute stroke was calculated and showed
37.6% , 28.5% , 25.6% , 6.4% and 2.5% (Chronic Kidney
Disease stage 0, 1,2,3,4,5 respectively.)
Conclusion :One Third of patients with acute stroke had
Glomerular Filtration Rate less than 60ml/min per 1.73m²
patients who had more than 2 risk factors of Chronic
Kidney Disease are about 3 times more likely to have
Glomerular Filtration Rate less than 60 ml/min per
1.73m² to those with 2 or less risk factors
Every year, millions of tons of waste glass are created across the globe. It is disposed of in landfills, which is unsustainable since it does not disintegrate into the environment. This study aims to produce reactive powder concrete by using recycled glass powder and determine the influence on the mechanical properties. This study investigated the effect of partial replacement of cement with recycled glass powder at two percentages (0, 20) % by weight of cement on some mechanical properties (Fresh density, Splitting tensile strength, Impact Strength, and voids%) of reactive powder concrete containing 1 % micro steel (MSRPC). Furthermore, using steam curing for (5 hours) at 90 degrees celsius after hardening the sample directly, RPC was
... Show MoreA precise evaluation of caries excavation endpoint is essential in clinical and laboratory investigations. Caries invasion differentiates dentin into structurally altered layers. This study assessed these changes using Raman spectroscopy and Vickers microhardness. Ten permanent molars with occlusal and proximal carious lesions were assessed and compared at 130 points utilizing four Raman spectroscopic peaks: phosphate v1 at 960 cm−1, amide I (1650 cm−1), amide III (1235 cm−1) and the C-H bond of the pyrrolidine ring (1450 cm−1). The phosphate-to-amide I peak ratio and collagen integrity peak ratio (amide III: C-H bond) of carious zones were calculated and compared in both lesions. The former ratio was correlated to 130 Vicke
... Show MoreRecently, dental implants have experienced increasing demand as one of the most effective, permanent and stable ways for replacing missing teeth. However, peri-implant diseases that are multispecies plaque-based infections may ultimately lead to implant failure (i.e., late peri-implantitis). Therefore, the present study aims to detect the microbial diversity of subgingival plaque in peri-implantitis cases (N = 30) by comparing with healthy implants (N = 34) using culture-based identification methods, including VITEK 2 system. An increase in microbial diversity (29 species along with 1 and 7 isolates, which were classified as a genus and unidentified species, respectively) were observed in subgingival sites of diseased implants dominated by
... Show MorePhotonic Crystal Fiber Interferometers (PCFIs) are greatly used
for sensing applications. This work presents the fabrication and
characterization of a relative humidity sensor based on Mach-
Zehnder Interferometer (MZI), which operates in reflection mode.
The humidity sensor operation based on the adsorption and
desorption of water vapour at the silica-air interface within the PCF.
The fabrication of this sensor is simple, it only includes splicing and
cleaving the PCF with SMF.PCF (LMA-10) with a certain length
spliced to SMF (Corning-28).
The spectrum of PCFI exhibits good sensitivity to humidity
variations. The PCFI response is observed for a range of humidity
values from (27% RH to 85% RH), the positi
It is an analytical study carried out at university of Basra using a sample included the dean ,assistants and managers of scientific dept. in the university for about(63)managers .The study aimed at discovering a model of crises management in the university.The researcher adopted the descriptive survey methodology.To achieve the objective of the study ,a questionnaire of (41)statements was developed covering five main variables like ,signal detection, prevention and preparedness, response, recovery and learning .The validity of the questionnaire was done by a group of referees .Its stability was determined by Cronbach,s Alfa .The questionnair,s stability coefficient was(0.
... Show MoreSalbutamol sulphate nebules is considered as the most rapid effective route of
administration for treatment of acute attacks of asthma .
This study was carried out to formulate a stable formula of salbutamol nebules
containing 0.1% (2.5mg / 2.5ml) of the active ingredient in a buffered solution .
Stability study in different buffers at pH 3 showed that the longest shelf life was
equal to 3.5 years for formula F .In addition the bioequivalency of this formula
incomparison to ventolin® nebules was measured and it was equal to (± 5.2) %.
Also it was found that there was no significant difference between the formula
and ventolin® nebules regarding their pharmacokinetic parameters which include
elimination
Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreThe neutron flux in this paper, which is generated as a result of γ incineration of the radioactive fisssion products isotopes has been evaluated .It is obvious from this paper that the neutron flux value depends on the number of incineration nuclei and the nuclear cross-section of the incinerated isotopes, and the neutron flux is directly dependent on γ-ray flux. The neutron flux increases from 1010to 1017n/s.gm as the irradiation flux increases from 1016to 1020 γ/cm2.s. It is concluded that the γ-incineration technique can be used to produce a switchable neutron source of high flux.
The Al Mishraq site has been the subject of many scientific studies for the period before and
after the fire in 2003. Five visits to the site were conducted twice in 2003 for general fact-finding, twice
in 2004, and once in 2005 for detailed sampling and monitoring. Desk-based research and laboratory analysis of soil and water samples results indicate that surface water and groundwater pollution from Al Mishraq site was significant at the time of its operation. The primary pollution source was the superheated water injection process, while the principal receptor is the River Tigris. Now that the plant is idle, this source is absent. Following the June 2003 sulphur fire, initial investigations indicate that short damage to
vegeta
Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range
... Show More