Objective: to evaluate the benefit of coverage of
the urethral repair by dorsal dartos flap as a second
layer for preventing fistula and V like incision on
the tip of the glans for preventing meatal stenosis.
Patients and Methods:
Forty five children included in this study age
ranged ( 11 months – 7 years), they underwent
hypospadias repair between December 2008 to
March 2012, all cases with distal hypospadias,
same technique used for all patients, a combination
of techniques used for reconstruction starting
withtubularized incised plate urethroplasty with deepithelialized
or stripping of the skin from both
sides of U shaped incision surrounding the urethral
plate, adding a V like incision on the top (tip of
glans) of the midline urethral plate incision that
give wide meatus subsequently prevent meatal
stenosis and no need for dilatation after stent
removal, followed by harvesting well vascularized
dartos flap from de-epithelialized preputial skin
and transposing itventrally by buttonholing
maneuver and suturing the flap as a second layer
along the neourthral suture line, finally
approximation of glans , so achieving three layer
closure.
Results :All patients are followed for (6 months-
24 months) mean was 15 months, only two patients
(4.4%) complicated with small fistula at the
subcoronal region at the beginning of the study
operated after 6 months and the fistula closed
successfully. Twenty five cases (55.5%) with
Chordee were completely released with no
recurrence. No dilatation was needed after removal
of stent for neomeatus developed a good stream of
urine with no problems regarding stenosis.
Conclusions: In this study hypospadias repair
should achieve three layer closures by using a
dartosfalp as a second layer to cover neourethral
suture line combined with stripping the skin on the
edge of the U shaped incision to gain secure
closure of the neourethra, which will prevent
fistula formation. We recommend adding a
Vincision on the tip of the glans connected with
midline urethral plate incision to prevent meatal
stenosis.
Ball and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes
... Show MoreObjective: To study the effect of epidural spinal injection over one year in case of spinal stenosis. Methodology: This prospective study included 566 patients with spinal stenosis seen at Al-Kindy Teaching and Al-Sader, Hospitals who were treated by local epidural steroid injection. They were followed up for at least five subsequent visits after seven days, one month, three months, six months, and one year to assess efficacy. Result: Mean age of patients was 49.5 years, with a predominance of females (65%). L4/L5 was the most involved level in the spinal stenosis (70%). Grade II stenosis accounted for (45.4%) of cases. The pairwise comparison revealed that there was significant decrease in proportions of patients with pain in day
... Show MoreArterial aneurism and stenosis are disorders that lead to circulation malfunction. Stenosis often leads to hypoxia of the organ depending on the affected artery, whilst aneurism can lead to dissection with known lethal consequences. On both cases, the pulse wave produced by the contracting heart is reflected at these discontinuities, and estimating the size of these reflected waves using wave intensity analysis (WIA) is the main aim of this work. We also aim to measure wave speed, or pulse wave velocity (PWV) as more commonly known within the discontinuities. We manufactured 4 stenosis and 4 aneurism silicon sections, connected one at a time to a mother tube, and tested in vitro. Pressure and flow were measured proximal to the discontinuity
... Show MoreBackground: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.
This paper presents an approach to license plate localization and recognition. A proposed method is designed to control the opening of door gate based on the recognition of the license plates number in Iraq. In general the system consists of four stages; Image capturing, License plate cropping, character segmentation and character recognition. In the first stage, the vehicle photo is taken from standard camera placed on the door gate with a specific distance from the front of vehicle to be processed by our system. Then, the detection method searches for the matching of the license plate in the image with a standard plate. The segmentation stage is performed by is using edge detection. Then character recognition, done by comparing with templ
... Show MoreBack ground: In Iraq, after 2003 had more
accidents of the shell, bullet and stab abdominal
wounds, more over colon injuries.
Objective: The aim of this study is to evaluate
the most appropriate management of penetrating
colon injuries, comparing the primary repair with
the diversion.
Methods: Eighty patient series with shell, bullet
and stab colonic injuries during 4.5 years period
from June 2006-december 2010 at Al-Yarmouk
teaching hospital. The study compared the use of
primary repair versus diversion, analyzing
variables such as sex, age, severity of injury and
mortality rate.
Results: there were total 80 patients ,62 (77.5%)
male and 18(22.5%) female .male :female ratio
3.4:1. the most
An experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air
... Show MoreBackground: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages rang
... Show More