Background: Humeral diaphyseal fracture usually
heals with closed methods but when nonunion
develops then it needs surgical intervention in the
form of plating and bone grafting, intramedulary
nailing (open or closed simple or interlocking nails)
and external fixators (circular or one plane fixator).
In our unit we treated non union humeral
diaphyseal fracture with plating and bone grafting
shortening of fracture ends up to 4 to 5cm when
needed. Methods: This study was conducted at
Orthopaedic Department of AL-Sadar General
Hospital from January 2004 till December2005 .
We included 20 cases with atrophic non-union in
12(60%) and hypertrophic non-union in 8 (40%)
patients. All atrophic non-union were treated with
plating, bone shortening by transverse osteotomy
and bone grafting, while hypertrophic non-union
were treated with decortications of non-union ends
and fixation with compression plates, with bone
grafting in old age. Follow up measures were based
on clinical (range of joints motion) and radiological
(healing) findings. Follow up was done for upto 6
months . Results: Out of 20 patients the age range
was 20- 60 years, 16 (80%)were male and 4(20%)
female. Right humerus involved in 15( 75 %)
while left humerus in 5( 25%) patients.
In12(60%) patients with atrophic non union bone
shortening by transverse cut osteotomy was done
while in remaining patients with hypertrophic nonunion
plating was done in 2( 10 %) cases and
plating with bone grafting in 6( 30%) patients.
Union was achieved in all patients after 16 to 20
weeks of surgery. In one patient ( 5 %) of 75 years
age with hypertrophic non-union implant was
loosened after 3 months of surgery. At that time
healing (Union) was evident on X-rays and humeral
brace was applied for further 3 months. Two
patients( 10 %) got neuropraxia of radial nerve
which resolved with in 3 months time. 2 patients
(10 %) developed shoulder stiffness which resolved
after exercise. Conclusion: In Non Union of
Humerus shortening by transverse osteotomy &
rigid fixation with plates give excellent results in
selected cases.
Le professeur Taranne et La non-Communication
Many of the key stream generators which are used in practice are LFSR-based in the sense that they produce the key stream according to a rule y = C(L(x)), where L(x) denotes an internal linear bit stream, produced by small number of parallel linear feedback shift registers (LFSRs), and C denotes some nonlinear compression function. In this paper we combine between the output sequences from the linear feedback shift registers with the sequences out from non linear key generator to get the final very strong key sequence
The effect of superficial gas velocity within the range 0.01-0.164 m/s on gas holdup (overall, riser and down comer), volumetric oxygen mass transfer coefficient, liquid circulation velocity was studied in an internal loop concentric tubes airlift reactor (working volume 45 liters). It was shown that as the usg increases the gas holdup and also the liquid circulation velocity increase. Also it was found that increasing superficial gas velocity lead to increase the interfacial area that increases the overall oxygen mass transfer coefficient. The hydrodynamic experimental results were modeled with the available equations in the literature. The predicted data gave an acceptable accuracy with the empirical data.
The final
... Show Moreتشغل الفضاءات الداخلية الطبية اهتمام واسع , لما توفره من رعاية صحية للمرضى ,فلابد ان يُهتَمْ بها من الجانب الوظيفي(الادائي), لتحقيق الراحة البصرية والنفسية والجسدية لغرض الوصول الى الاداء الجيد للكادر الطبي, ولهذا وجد ضرورة التعرف على تلك الفضاءات الداخلية بشكل اعمق , وهل انها ملاءمة للمرتكزات التصميمية المتعارف عليها؟ , لذلك تم تسليط الضوء على الفضاءات الداخلية للمختبرات الطبية, وقد تناول البحث المشكلة واه
... Show MoreMagnetic Abrasive Finishing (MAF) is an advanced finishing method, which improves the quality of surfaces and performance of the products. The finishing technology for flat surfaces by MAF method is very economical in manufacturing fields an electromagnetic inductor was designed and manufactured for flat surface finishing formed in vertical milling machine. Magnetic abrasive powder was also produced under controlled condition. There are various parameters, such as the coil current, working gap, the volume of powder portion and feed rate, that are known to have a large impact on surface quality. This paper describes how Taguchi design of experiments is applied to find out important parameters influencing the surface quality generated during
... Show Moreيعد التقطيع الصوري من الاهداف الرئيسة والضرورية في المعالجات الصورية للصور الرقمية، فهو يسعى الى تجزئة الصور المدروسة الى مناطق متعددة اكثر نفعاً تلخص فيها المناطق ذات الافادة لصور الاقمار الصناعية، وهي صور متعددة الاطياف ومجهزة من الاقمار الصناعية باستخدام مبدأ الاستشعار عن بعد والذي اصبح من المفاهيم المهمة التي تُعتمد تطبيقاته في اغلب ضروريات الحياة اليومية، وخاصة بعد التطورات المتسارعة التي شهد
... Show MoreThe research aims to verify the Role of Internal Auditing in Assessing the Risks of Strategic Operations (Acquisition) and then reflect on management decisions. Since all corporations wish to expand, growth and domination of the market may expose them to multiple risks that lead to failure. The research assumes two main hypotheses. First, there is no role for internal audit in evaluating the strategic operations (acquisition). Second, there is no relationship between internal auditing in assessing the risks of strategic operations (Acquisition) and management decisions. The data was collected by using a questionnaire distributed to a group of private bank employees. The statistical analysis regarding research rejected the two hyp
... Show More