Background: Humeral diaphyseal fracture usually
heals with closed methods but when nonunion
develops then it needs surgical intervention in the
form of plating and bone grafting, intramedulary
nailing (open or closed simple or interlocking nails)
and external fixators (circular or one plane fixator).
In our unit we treated non union humeral
diaphyseal fracture with plating and bone grafting
shortening of fracture ends up to 4 to 5cm when
needed. Methods: This study was conducted at
Orthopaedic Department of AL-Sadar General
Hospital from January 2004 till December2005 .
We included 20 cases with atrophic non-union in
12(60%) and hypertrophic non-union in 8 (40%)
patients. All atrophic non-union were treated with
plating, bone shortening by transverse osteotomy
and bone grafting, while hypertrophic non-union
were treated with decortications of non-union ends
and fixation with compression plates, with bone
grafting in old age. Follow up measures were based
on clinical (range of joints motion) and radiological
(healing) findings. Follow up was done for upto 6
months . Results: Out of 20 patients the age range
was 20- 60 years, 16 (80%)were male and 4(20%)
female. Right humerus involved in 15( 75 %)
while left humerus in 5( 25%) patients.
In12(60%) patients with atrophic non union bone
shortening by transverse cut osteotomy was done
while in remaining patients with hypertrophic nonunion
plating was done in 2( 10 %) cases and
plating with bone grafting in 6( 30%) patients.
Union was achieved in all patients after 16 to 20
weeks of surgery. In one patient ( 5 %) of 75 years
age with hypertrophic non-union implant was
loosened after 3 months of surgery. At that time
healing (Union) was evident on X-rays and humeral
brace was applied for further 3 months. Two
patients( 10 %) got neuropraxia of radial nerve
which resolved with in 3 months time. 2 patients
(10 %) developed shoulder stiffness which resolved
after exercise. Conclusion: In Non Union of
Humerus shortening by transverse osteotomy &
rigid fixation with plates give excellent results in
selected cases.
The problem of the study was to identify the possibility of benefiting from the application of the target cost system as a modern cost system to activate the environmental cost management instead of the traditional systems used in the company due to the great transformations witnessed by the business environment in all fields, which have resulted in the search for modern systems to provide more accurate and more appropriate information to reduce Costs, because accurate information makes the company have a complete vision to achieve the company’s goals. To solve this problem, the research was based on the following hypothesis (that the role of the target cost system leads to the activation of environmental cost management). Target c
... Show MoreIn wide range of chemical, petrochemical and energy processes, it is not possible to manage without slurry bubble column reactors. In this investigation, time average local gas holdup was recorded for three different height to diameter (H/D) ratios 3, 4 and 5 in 18" diameter slurry bubble column. Air-water-glass beads system was used with superficial velocity up to 0.24 m/s. the gas holdup was measured using 4-tips optical fiber probe technique. The results show that the axial gas holdup increases almost linearly with the superficial gas velocity in 0.08 m/s and levels off with a further increase of velocity. A comparison of the present data with those reported for other slurry bubble column having diameters larger than
... Show MoreAl-Qudis power plant was chosen, as one of the power stations of Baghdad, to investigate the effects of Cadmium that emitted from combustion of crude oil in that power plant on the workers' glutathione serum level. Air samples were taken seasonally during August 2011- July 2012 from four sites at Al- Qudis power plant which are oil treatment unit 1(site 1), oil treatment 2 (site2), pre –chimney 1(site 3) and pre-chimney 2 (site 4), to measure levels of heavy metal (cadmium) under study. Blood samples were collected from the workers to estimate the heavy metal Cadmium. Air cadmium levels during summer (August and September) were varied from 6.26 ± 0.6 μg/m3 at site 1 to 6.89 ± 0.67 μg/m3 at site 3, while in spring (end of March, and
... Show MoreAbstract: Background: Staphylococcus aureus is Gram-positive bacteria that lives as a normal flora in living organisms but can be pathogenic to humans. Although a relatively unspectacular, nonmotile coccoid bacterium, S. aureus is a dangerous human pathogen in both community-acquired and nosocomial infections. Due to the increasing emergence of new strains of this antibiotic-resistant bacteria, it has become essential to approach different methods to control this pathogen. One of these methods is the antimicrobial photodynamic inactivation process using a low-level laser, in this paper, the Photodynamic effects of Rose Bengal and LLLL on the virulence factors of S.aureus were evaluated.
Abstract:
Objective: The study’s aim to evaluate the effectiveness of instructional program about healthy lifestyle on patients’ attitudes after undergoing percutaneous coronary intervention.
Methodology: Quasi-experimental design/ has been utilized for the current study starting from December 2018 to March 2020 to achieve the objectives of the study. Non-probability (purposive) sample of 60 patients was divided into intervention and control groups. Data were analyzed by the application of descriptive and inferential statistical methods.
Results: findings reported that before intervention both study and control groups demonstrated low total mean of score relat
... Show MoreThe aim of this article is to solve the Volterra-Fredholm integro-differential equations of fractional order numerically by using the shifted Jacobi polynomial collocation method. The Jacobi polynomial and collocation method properties are presented. This technique is used to convert the problem into the solution of linear algebraic equations. The fractional derivatives are considered in the Caputo sense. Numerical examples are given to show the accuracy and reliability of the proposed technique.
Lead-acid batteries have been used increasingly in recent years in solar power systems, especially in homes and small businesses, due to their cheapness and advanced development in manufacturing them. However, these batteries have low voltages and low capacities, to increase voltage and capacities, they need to be connected in series and parallel. Whether they are connected in series or parallel, their voltages and capacities must be equal otherwise the quality of service will be degraded. The fact that these different voltages are inherent in their manufacturing, but these unbalanced voltages can be controlled. Using a switched capacitor is a method that was used in many methods for balancing voltages, but their respons
... Show MoreAl-Qudis power plant was chosen, as one of the power stations of Baghdad, to investigate the effects of Cadmium that emitted from combustion of crude oil in that power plant on the workers' glutathione serum level. Air samples were taken seasonally during August 2011- July 2012 from four sites at Al- Qudis power plant which are oil treatment unit 1(site 1), oil treatment 2 (site2), pre –chimney 1(site 3) and pre-chimney 2 (site 4), to measure levels of heavy metal (cadmium) under study. Blood samples were collected from the workers to estimate the heavy metal Cadmium. Air cadmium levels during summer (August and September) were varied from 6.26 ± 0.6 μg/m3 at site 1 to 6.89 ± 0.67 μg/m3 at site 3, while in spring (end of March, and
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show More