Preferred Language
Articles
/
jkmc-522
Preparation of Vaccine against Diabetic Foot Pathogenic Bacteria Using Low Level Diode Laser

Background: Since the invention of laser in 1960, lasers have been developed and approved in many fields. Lasers can now be regarded as practical tools with unique properties that have been utilized effectively in several applications in fields of medical and biological sciences.Objectives: The aim of the current study was to preparation of vaccines (live attenuated and killed) by irradiation of the bacteria by the low level diode laser.Methods: six bacterial isolates were isolated from human samples of diabetic foot infections, which used for preparation of vaccines. The experiment was conducted on fifteen adult male rabbits; they were divided into three groups with 5 rabbits each. Blood samples were collected from the marginal ear vein of the rabbits after one month of the vaccination, for the purpose of measuring the concentration of the immunoglobulins which present in their serum, using Radial Immunodiffusion (RID) method by specialized kits (LTA-Italy).Results: After irradiation of the bacterial suspensions with the diode laser for different exposure times and different frequencies, and the wavelengths used were (660, 820, 915) nm, the growth of bacterial isolates decreased until killed of bacteria at 40 min. The results of IgA concentrations for the three groups were highly significant (P < 0.01) when comparing the attenuated with control group, while were significant (P < 0.05) between the killed vaccine and control groups, and not significant variations between the attenuated and killed groups,Conclusions: Wavelength (660) nm was more effective in killing the bacteria, and the variations were not significant between the live attenuated and the killed vaccine

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Thu Jan 20 2011
Journal Name
مجله كليه التربيه الاساسيه
Determination of Antimicrobial Activity of Thuja orientalis Against Some Pathogenic Microorganisms

The present study was conducted to investigate the antimicrobial activity of the hot water and the hot ethanolic extracts of Thuja orientalis against some pathogenic microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Eschericha coli, Proteus mirrablis, Salmonilla typhi, Klebsiella pneumoniae, Bacillus cereus, Bacillus subtilus, Acinobacter, Staphylococcus epidermidis and Candida albicans). Results showed that both the water and alcoholic extracts of this plant exert marked inhibitory effect against all the bacterial isolates and yeast and at different ratio, and it was shown that ethanolic extract was more effective in microbial inhibition than the water extract. Maximum inhibition (16 mm) was recorded against Staphylococcus aur

... Show More
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Research In Medical Sciences
Scopus (21)
Crossref (18)
Scopus Clarivate Crossref
View Publication
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Photodynamic effect of Rose Bengal activated by low-level laser light on S. aureus : Qusay K. Abbas*, Layla M. Hassan

Abstract: Background: Staphylococcus aureus is Gram-positive bacteria that lives as a normal flora in living organisms but can be pathogenic to humans. Although a relatively unspectacular, nonmotile coccoid bacterium, S. aureus is a dangerous human pathogen in both community-acquired and nosocomial infections. Due to the increasing emergence of new strains of this antibiotic-resistant bacteria, it has become essential to approach different methods to control this pathogen. One of these methods is the antimicrobial photodynamic inactivation process using a low-level laser, in this paper, the Photodynamic effects of Rose Bengal and LLLL on the virulence factors of S.aureus were evaluated.

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Isolation of Some Pathogenic Bacteria and Fungi From Student Mobile Phones (Part I)

Background: Mobile phones are approximately widely used everywhere like in hospital wards, clinics and universities as well as biomedical laboratories. They have become very important tool in students’ life. In contrast, these tools carry many harmful bacteria which are responsible for infectious diseases in human because they serve as a reservoir for different pathogens. Current study was aimed to isolate bacteria from students’ mobile phones at the Institute of Medical Technology/Al-Mansour/The Middle Technical University, Baghdad, Iraq. Also, the study investigated microbial resistance to many antimicrobial agents as well as the appropriate remedial measures. Method: Four hundred and fifty swabs from mobile phones were collected from

... Show More
View Publication
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Bioactive Effect of Cinnamomum zealynicum bark Extracts on Some Locally Isolated Pathogenic Bacteria

A series of experiments were conducted to evaluate the antibacterial effect of Cinnamomum zealynicum bark aqueous , methanol, and chloroform extracts against some gram positive and gram negative pathogenic bacteria which isolated from wound, throat infection, urine and stool during the period from December /2013 to February /2014 from Alkarama hospital in Wasit. All these isolates were identified by using VITEK2 compact system. Antibiotic sensitivity test of the bacterial isolates was determined for ten antibiotics. Chemical analysis showed that Cinnamomum zeylanicum bark extracts contained different active compounds (phenoles, alkaloids, tannins, glycosides, coumarins, saponins, resins flavones and essential oil). The laboratory tests o

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Biological & Immunological Effect of Ozonated Water on Certain Skin Pathogenic Bacteria In vivo

This in vivo study was conducted to investigate the effect of different concentrations of ozonated water on experimentally skin infection with some of bacterial isolates (Pseudomonas aeruginosa and Staphylococcus aureus ) which Showed dermal infection in experimental animals after 48 hours of exposure to these Microorganisms. Results revealed that ozone has the power to accelerated the healing process depending on the perfect concentration of ozonated water used and the severity of infection & nature of causative agent , in which the recovering period was 7 days for the infection caused by P. aeruginosa and 5 day for S.aureus by using the concentration 60 µg/ml . Results also indicated in this study the stimulated effect of O

... Show More
View Publication Preview PDF