Preferred Language
Articles
/
jkmc-49
Early Detection of Left Ventricular Systolic Dysfunction in Asymptomatic Patients with Chronic Aortic Regurgitation by two Dimensional Speckle Tracking Echocardiography

Background: Early detection of subclinical left ventricular (LV) systolic dysfunction is crucial and could influence patients' prognosis by aiding the clinician to candidate patients for better management.

Objective: To detect early LV systolic dysfunction in asymptomatic patient with chronic aortic regurgitation by two dimensional speckle tracking echocardiography.

 Methods:  Sixty one asymptomatic patients with chronic aortic regurgitation, with no ischemic heart diseases (by coronary angiography) or conductive heart diseases, no diabetes mellitus, no hypertension, and no other valvular heart diseases (group 1) and fifty age and sex-matched healthy subjects (group 2) were enrolled into the study. Group (1) was further classified into 3 sub-groups according to 4 chosen parameters from the published guidelines of American Society of Echocardiography (ASE) into: Mild AR, Moderate AR, and Severe AR.

  All patients and controls underwent echocardiographic examination including conventional echocardiography, tissue Doppler study and Two Dimensional (2-D) Speckle Tracking Echocardiography.

Results: GLS showed the highest sensitivity and specificity in detection of subtle LV systolic dysfunction in moderate AR. In moderate AR,a cut off value of > (-19.62) has sensitivity and specificity of 91.3% and 95.5% respectively, with Positive Predictive Value (PPV) and Negative Predictive Value ( NPV ) of 87.5% and 96.9% respectively, Area under curve (AUC) of 0.981. In all types of AR, GLS had higher NPV than PPV which makes it a powerful screening tool for early detection of subtle LV systolic dysfunction.

Conclusion: Global Longitudinal strain measured by 2-D speckle tracking echocardiography is an excellent tool for early detection of subtle LV systolic dysfunction in asymptomatic patients with chronic AR

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 25 2022
Journal Name
American Scientific Research Journal For Engineering, Technology, And Sciences
Design and Fabrication of an Electromechanical Tester to Perform Two-dimensional Tensile Testing for Flexible Materials

There are many diseases that affect the arteries, especially those related to their elasticity and stiffness, and they can be guessed by estimating and calculating the modulus of elasticity. Hence, the accurate calculation of the elastic modulus leads to an accurate assessment of these diseases, especially in their early stages, which can contribute to the treatment of these diseases early. Most of the calculations used the one-dimensional (1D) modulus of elasticity. From a mechanical point of view, the stresses to which the artery is subjected are not one-dimensional, but three-dimensional. Therefore, estimating at least a two-dimensional (2D) modulus of elasticity will necessarily be more accurate. To the knowledge of researchers, there i

... Show More
Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Design and Implementation of an Automatic Control for Two Axis Tracking System for Applications of Concentrated Solar Thermal Power

The present work presents design and implementation of an automated two-axis solar tracking system using local materials with minimum cost, light weight and reliable structure. The tracking system consists of two parts, mechanical units (fixed and moving parts) and control units (four LDR sensors and Arduino UNO microcontroller to control two DC servomotors). The tracking system was fitted and assembled together with a parabolic trough solar concentrator (PTSC) system to move it according to information come from the sensors so as to keep the PTSC always perpendicular to sun rays. The experimental tests have been done on the PTSC system to investigate its thermal performance in two cases, with tracking system (case 1) and without trackin

... Show More
Crossref
View Publication Preview PDF
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Analyzing Laser Speckle Pattern Using the Discrete Cosine Transform

The use of Cosine transform to analyze the model-noise pattern alteration with different vibration model applied on multimode fiber optics are studied. It's results compared with the Fourier transform to perform the same analysis using total frequency difference and the computation time, which almost coincide for the both transforms. A discussion for the results and recommendation are introduced.

View Publication Preview PDF
Publication Date
Tue Jul 11 2017
Journal Name
The 39th Annual International Conference Of The Ieee Engineering In Medicine And Biology Society (embc'17)
Higuchi fractal dimension of the electroencephalogram as a biomarker for early detection of Alzheimer's disease

It is widely accepted that early diagnosis of Alzheimer's disease (AD) makes it possible for patients to gain access to appropriate health care services and would facilitate the development of new therapies. AD starts many years before its clinical manifestations and a biomarker that provides a measure of changes in the brain in this period would be useful for early diagnosis of AD. Given the rapid increase in the number of older people suffering from AD, there is a need for an accurate, low-cost and easy to use biomarkers that could be used to detect AD in its early stages. Potentially, the electroencephalogram (EEG) can play a vital role in this but at present, no reliable EEG biomarker exists for early diagnosis of AD. The gradual s

... Show More
Scopus (44)
Crossref (31)
Scopus Crossref
View Publication
Publication Date
Mon Oct 01 2012
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Evaluating the utility of plasma Atherogenic Index among several atherogenic parameters in patients with chronic renal Failure on maintenance hemodialysis

Background: Patients with chronic renal failure undergoing longterm hemodialysis (HD) are prone to atherosclerosis and at increased risk of developing cardiovascular diseases.
Objective: The objective of this study is to compare atherogenic index of plasma (AIP) in predicting the risk of cardiovascular disease (CVD) in patients with chronic renal failure (CRF) on regular hemodialysis, when associated with other chronic diseases.
Patients and methods: A total of forty male patients with CRF on hemodialysis, matched in, age, body mass index BMI, and duration of hemodialysis were enrolled. They were grouped as group 1 (G1) includes eleven subjects with CRF without (hypertension and / or diabetes) groups 2 (G2) fourteen CRF subjects wi

... Show More
Crossref
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Medicinal And Chemical Sciences
Echocardiographic Assessment of the Aortic Stenosis Valve Area: Parameters and Outcome

Background: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.

Scopus (10)
Scopus
Publication Date
Sun Jun 12 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effectiveness of Ombitasvir with Paritaprevir/Ritonavir plus Ribavirin on the Treatment of Naïve Patients with Chronic Hepatitis C Virus Genotype 4

Background Direct-acting antivirals (DAAs) combination therapies from various mechanisms of action and families have been revolutionized the management landscape of chronic hepatitis C virus (HCV). Ombitasvir, paritaprevir with ritonavir (OBV/PTV/r) ± ribavirin (RBV) is approved to treat HCV genotype 4 (GT4) infection. Here, our objective was to delineate the efficacy and safety of OBV/PTV/r plus RBV in treating of Egyptian naïve patients infected with HCV GT4.

Methods a cohort of 100 Egyptian patients infected with HCV GT4 was allocated and administered orally OBV/PTV/r with RBV. The primary endpoint of our study was a sustained virological response (HCV RNA < 12 IU/mL) 12 weeks after the c

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Tue Sep 30 2014
Journal Name
J Clin Biomed Sci
Detection of EGFR Mutations in Bronchial Wash from Iraqi patients with nonsmall Cell Lung Cancer (NSCLC)

Background: Non-small cell lung cancer (NSCLC) is caused of 85% of all lung cancers. Among the most important factors for lung tumor growth and proliferation are the tyrosine kinase receptors that coded by the epidermal growth factor recep-tor (EGFR) gene. Activation of EGFR ultimately leads to developing of lung cancer. The present study was undertaken with an objective to detect EGFR mutations in bronchial wash from Iraqi patients with NSCLC before treatment. Methods: DNA was extracted from bronchial wash samples collected from 50 patients with NSCLC by using a Qiamp DNA Mini Kit (Qiagen, Hilden, Germany). Then, EGFR mutations were determined by using real-time RCR combined with two technologies, Amplification Refractory Mutation System (

... Show More
Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Mathematics Trends And Technology (ijmtt)
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Multidimensional Systolic Arrays of LMS Algorithm Adaptive (FIR) Digital Filters

A multidimensional systolic arrays realization of LMS algorithm by a method of mapping regular algorithm onto processor array, are designed. They are based on appropriately selected 1-D systolic array filter that depends on the inner product sum systolic implementation. Various arrays may be derived that exhibit a regular arrangement of the cells (processors) and local interconnection pattern, which are important for VLSI implementation. It reduces latency time and increases the throughput rate in comparison to classical 1-D systolic arrays. The 3-D multilayered array consists of 2-D layers, which are connected with each other only by edges. Such arrays for LMS-based adaptive (FIR) filter may be opposed the fundamental requirements of fa

... Show More
View Publication Preview PDF