Preferred Language
Articles
/
jkmc-49
Early Detection of Left Ventricular Systolic Dysfunction in Asymptomatic Patients with Chronic Aortic Regurgitation by two Dimensional Speckle Tracking Echocardiography
...Show More Authors

Background: Early detection of subclinical left ventricular (LV) systolic dysfunction is crucial and could influence patients' prognosis by aiding the clinician to candidate patients for better management.

Objective: To detect early LV systolic dysfunction in asymptomatic patient with chronic aortic regurgitation by two dimensional speckle tracking echocardiography.

 Methods:  Sixty one asymptomatic patients with chronic aortic regurgitation, with no ischemic heart diseases (by coronary angiography) or conductive heart diseases, no diabetes mellitus, no hypertension, and no other valvular heart diseases (group 1) and fifty age and sex-matched healthy subjects (group 2) were enrolled into the study. Group (1) was further classified into 3 sub-groups according to 4 chosen parameters from the published guidelines of American Society of Echocardiography (ASE) into: Mild AR, Moderate AR, and Severe AR.

  All patients and controls underwent echocardiographic examination including conventional echocardiography, tissue Doppler study and Two Dimensional (2-D) Speckle Tracking Echocardiography.

Results: GLS showed the highest sensitivity and specificity in detection of subtle LV systolic dysfunction in moderate AR. In moderate AR,a cut off value of > (-19.62) has sensitivity and specificity of 91.3% and 95.5% respectively, with Positive Predictive Value (PPV) and Negative Predictive Value ( NPV ) of 87.5% and 96.9% respectively, Area under curve (AUC) of 0.981. In all types of AR, GLS had higher NPV than PPV which makes it a powerful screening tool for early detection of subtle LV systolic dysfunction.

Conclusion: Global Longitudinal strain measured by 2-D speckle tracking echocardiography is an excellent tool for early detection of subtle LV systolic dysfunction in asymptomatic patients with chronic AR

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of International Oral Health
Endothelin-1 is a surrogate biomarker link severe periodontitis and endothelial dysfunction in hypertensive patients: The potential nexus
...Show More Authors

Aim and Objectives: The objective of this study was to illustrate the link between periodontitis (PO) and endothelial dysfunction in hypertensive patients. Materials and Methods: This cross‑sectional study involved 53 hypertensive patients with or without PO compared with 28 healthy controls. On the basis of the study protocol, the participants were divided into three groups: Group (1): 24 patients with hypertension only, Group (2): 29 patients with hypertension and PO, and Group (3): 28 healthy controls. Lipid profile, endothelin‑1 (ET‑1), and high‑sensitivity C‑reactive protein (hs‑CRP) were measured. Blood pressure and body mass index (BMI) were evaluated. Diagnostic criteria of severe PO periodontal indices including plaque

... Show More
View Publication
Scopus (18)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Tue Apr 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Phototoxic effect of visible blue light on Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis in patients with chronic periodontitis (An in-vitro study)
...Show More Authors

Background: The aim of this study was to determine phototoxic effect of visible blue light on anaerobic periodontal pathogens namely Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis. Materials and methods: Strains of Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis were isolated from pockets of systemically healthy patients aged between 35-55 years old with pocket depths of 5-6 mm, the bacteria cultured on special blood Agar plates solid media, then subjected to visible blue light emitted from commercially available light cure devise (LED curing light); that emits blue light (400-500nm) of 1000mw energy at different periods of time exposures, then the CFU of each plate was measured by direct colony count

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 11 2020
Journal Name
Journal Of Cardiovascular Disease Research
Resistive Index is an Early Indicator for Flow Deterioration in Comparison with Intima Media Thickness for Patients with Hypertension and Diabetes in Relation to Age
...Show More Authors

Background: Atherosclerosis is well known related to age and certain cardiovascular diseases. Aging is one reason of arteries function deterioration which can cause loss of compliance and plaque accumulation, this effect increases by the presence of certain diseases such as hypertension and diabetes disease. Aim: To investigate the reduction of blood supply to the brain in patients with diabetes and hypertension with age and the role of resistive index in the diagnosis of reduced blood flow. Method: Patients with both diseases diabetic and hypertension were classified according to their age to identify the progression of the disease and factors influencing the carotid artery blood flow. By using ultrasound and standard Doppler techniq

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jun 26 2023
Journal Name
Journal Of Contemporary Medical Sciences
Molecular detection of mononucleotide biomarkers of microsatellite instability in sporadic colorectal carcinoma patients with clinicopathological correlation
...Show More Authors

Objectives: To identify the frequency and types of microsatellite instability among a group of sporadic CRC patients and to correlate the findings with clinicopathological characteristics. Methods: During an 8-month period, all patients with sporadic CRC who attended to two teaching hospitals in Baghdad, Iraq were recruited to this cross-sectional study regardless of age, sex, ethnicity, or tumor characteristics. Demographic, clinical, and histopathological features were recorded. DNA was extracted from FFPE-blocks of the resected tumors and normal tissues. PCR amplification of five microsatellite mononucleotide repeat loci (BAT25, BAT26, NR-21, NR-24, and MONO-27) and 2 pentanucleotide repeat control markers (Penta C and Pent

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Multidimensional Systolic Arrays of LMS Algorithm Adaptive (FIR) Digital Filters
...Show More Authors

A multidimensional systolic arrays realization of LMS algorithm by a method of mapping regular algorithm onto processor array, are designed. They are based on appropriately selected 1-D systolic array filter that depends on the inner product sum systolic implementation. Various arrays may be derived that exhibit a regular arrangement of the cells (processors) and local interconnection pattern, which are important for VLSI implementation. It reduces latency time and increases the throughput rate in comparison to classical 1-D systolic arrays. The 3-D multilayered array consists of 2-D layers, which are connected with each other only by edges. Such arrays for LMS-based adaptive (FIR) filter may be opposed the fundamental requirements of fa

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
Diagnostic Value Of Post Exercise Systolic Blood Pressure Response In Ischemic Heart Disease
...Show More Authors

 Background: The normal decline in systolic blood pressure during recovery phase of treadmill exercise dose not occur in most patients with coronary artery disease, in others recovery values systolic blood pressure may even exceed the peak exercise value. Objectives: Treadmill exercise test parameters indicating the presence and extent of coronary artery disease have traditionally included such as exercise duration, blood pressure and ST-segment response to exercise. The three –minute systolic blood pressure ratio is another important indicator of presence and significance of coronary artery disease is useful and obtainable measure that can be applied in all patients who are undergoing stress testing for evaluation of suspected is

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Design, Construction, and Control Tracking of Solar Thermal Concentrator by Using PLC in Erbil
...Show More Authors

This paper demonstrates the construction designing analysis and control strategies for fully tracking concentrated solar thermal by using programmable logic control in the city of Erbil-Iraq. This work used the parabolic dish as a concentrated solar thermal. At the focal point, the collected form of energy is used for heating a (water) in the receiver, analyzing this prototype in real-time with two different shapes of the receiver and comparing the results. For tracking the parabolic dish, four light-dependent resistors are used to detect the sun's position in the sky so that the tracking system follows it to make the beam radiation perpendicular to the collector surface all of the time during the day for maximum solar p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jul 11 2017
Journal Name
The 39th Annual International Conference Of The Ieee Engineering In Medicine And Biology Society (embc'17)
Higuchi fractal dimension of the electroencephalogram as a biomarker for early detection of Alzheimer's disease
...Show More Authors

It is widely accepted that early diagnosis of Alzheimer's disease (AD) makes it possible for patients to gain access to appropriate health care services and would facilitate the development of new therapies. AD starts many years before its clinical manifestations and a biomarker that provides a measure of changes in the brain in this period would be useful for early diagnosis of AD. Given the rapid increase in the number of older people suffering from AD, there is a need for an accurate, low-cost and easy to use biomarkers that could be used to detect AD in its early stages. Potentially, the electroencephalogram (EEG) can play a vital role in this but at present, no reliable EEG biomarker exists for early diagnosis of AD. The gradual s

... Show More
View Publication
Scopus (48)
Crossref (30)
Scopus Crossref
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Analyzing Laser Speckle Pattern Using the Discrete Cosine Transform
...Show More Authors

The use of Cosine transform to analyze the model-noise pattern alteration with different vibration model applied on multimode fiber optics are studied. It's results compared with the Fourier transform to perform the same analysis using total frequency difference and the computation time, which almost coincide for the both transforms. A discussion for the results and recommendation are introduced.

View Publication Preview PDF
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Subgroups and Orbits by Companion Matrix in Three Dimensional Projective Space
...Show More Authors

The aim of this paper is to construct cyclic subgroups of the projective general linear group over  from the companion matrix, and then form caps of various degrees in . Geometric properties of these caps as secant distributions and index distributions are given and determined if they are complete. Also, partitioned of  into disjoint lines is discussed.

View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref