Preferred Language
Articles
/
jkmc-474
Discrimination of Malignant from Acute Benign Compression Spinal Fractures with Magnetic Resonance imaging
...Show More Authors

Background: Differentiation between malignant and benign vertebral compression fracture is often problematic. This is precisely difficult in elderly who are predisposed to benign compression caused by osteoporosis .Establishing correct diagnosis is of great importance in determining the treatment andprognosis.A study was performed to determine which magnetic resonance imaging findings are useful in discrimination between metastatic and acute osteoporotic compression fractures of the spine. Recently MRI is being increasingly used for evaluation of these fractures.Objectives: The aim of this study is to establish the correct diagnosis of malignant and benign compression vertebral fracture by MRI to determine treatment and prognosis.Methods: MRI of (45 )patients with vertebral compression fracture who underwent MRI of spine during 2 years period ( 2004-2006) in Neuro surgical hospital were retrospectively reviewed by an expedient radiologist , A collapsed vertebra were considered to be acute if there was recent history of back pain of less than 3moths. All MRI sequences needed for spine examination was done( T1WI SE, T2WI GE STIR, and Mylography ) and Gadolinium contrast medium was given to all patients..Results: Of total 45 patients (31male, 14 female, their age range between 18-72years) , The criteria used to differentiate between benign andmalignant collapse spine on MRI was based on the signal intensity, morphology and contrast enhancement for the correct diagnosis. Homogenous and diffuse abnormal signal intensity, posterior convexity and involvement of pedicles are sign that are strongly suggestive of malignant collapse .Conversely, a band like area of low signal intensity adjacent to depressed end plateand preservation of signal intensity of vertebra suggest benign nature of the collapse.Conclusions: We found that MRI features is helpful in differentiation of malignant and benign compression fractures in majority of cases, and if initial MRI finding are equivocal correlation with other images technique, follow up and biopsy in selected cases helpful in arriving correct diagnosis

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
The Energy Spectra and Heat Capacity of GaAs Gaussian Quantum Dot in an External Magnetic Field
...Show More Authors

In this paper, a theoretical study of the energy spectra and the heat capacity of one electron quantum dot with Gaussian Confinement in an external magnetic field are presented. Using the exact diagonalization technique, the Hamiltonian of the Gaussian Quantum Dot (GQD) including the electron spin is solved. All the elements in the energy matrix are found in closed form. The eigenenergies of the electron were displayed as a function of magnetic field, Gaussian confinement potential depth and quantum dot size. Explanations to the behavior of the quantum dot heat capacity curve, as a function of external applied magnetic field and temperature, are presented.

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Mar 19 2019
Journal Name
Al-khwarizmi Engineering Journal
Optimization of Material Removal Rate and Temperature in Magnetic Abrasive Finishing Process for Stainless Steel 304
...Show More Authors

The effect of the magnetic abrasive finishing (MAF) method on the temperature rise (TR), and material removal rate (MRR) has been investigated in this paper. Sixteen runs were to determine the optimum temperature in the contact area (between the abrasive powder and surface of workpiece) and the MRR according to Taguchi orthogonal array (OA). Four variable technological parameters (cutting speed, finishing time, working gap, and the current in the inductor) with four levels for each parameter were used, the matrix is known as a L16 (44) OA. The signal to noise ratio (S/N) ratio and analysis of the variance (ANOVA) were utilized to analyze the results using (MINITAB17) to find the optimum condition and identify the significant p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 15 2026
Journal Name
Al-nahrain Journal For Engineering Sciences
The Effect of Magnetic Abrasive Finishing on the Flat Surface for Ferromagnetic and non-Ferromagnetic materials
...Show More Authors

Magnetic Abrasive Finishing (MAF) is an advanced finishing method, which improves the quality of surfaces and performance of the products. The finishing technology for flat surfaces by MAF method is very economical in manufacturing fields an electromagnetic inductor was designed and manufactured for flat surface finishing formed in vertical milling machine. Magnetic abrasive powder was also produced under controlled condition. There are various parameters, such as the coil current, working gap, the volume of powder portion and feed rate, that are known to have a large impact on surface quality. This paper describes how Taguchi design of experiments is applied to find out important parameters influencing the surface quality generated during

... Show More
View Publication
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Inelastic magnetic electron scattering M1 form factors in Ca-48 (M3Y fitting parameters consideration)
...Show More Authors

Inelastic magnetic electron scattering M1 at Ex =10.23 MeV form factors in Ca-48 have been investigated. The fp shell model space with four orbits and eight neutrons have been considered and FPD6 has been selected between 32 model space effective interactions to generates the model space vectors for the M1 transition with excitation energy Ex =10.23 MeV and for constructing OBDM. Discarded space (core and higher configuration orbits) has been included through the first order perturbation theory to couple the partice-hole pair of excitation in the calculation of the total M1 form factor and regarding the realistic interaction M3Y as a core polarization interaction with six sets of fitting parameters. Finally the theoretical calculations h

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 01 2007
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Isolation of some microorganisms from Iraqi patients with chronic maxillary sinusitis.
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Natural Sciences Research
Genetic Study for G-Protein Coupled Receptor from Saccharomyces Cerervisiae and From Sera of Patients with Heart Thrombosis
...Show More Authors

Aim of the present study is Identification of specific gene for GPCR using specific primers .and identification of difference in PCR analysis in patients with heart thrombosis and compared with healthy, Sequencing of PCR product regarding GPCR compared for all three subject, Identification the similarity of human GPCR with local strain of yeast fifty healthy control and fifty patients with thrombosis which diagnosed medically with cardiac specific troponin t, troponin 1 levels and electro myocardiogram ECG. The aged for all subjects ranged (39-75) years patients were lying in cardiac care unit at Ibn- al- Nafees teaching hospital and Sheikh Zayed teaching hospital. Genomic DNA of whole blood was extracted from buffy coat and cell cu

... Show More
View Publication
Publication Date
Mon Mar 18 2019
Journal Name
Civil Engineering Journal
Circularization Technique for Strengthening of Plain Concrete Short Square Columns Subjected to a Uniaxial Compression Compressive Pressure
...Show More Authors

This paper presents an experimental study for strengthening existing columns against axial compressive loads. The objective of this work is to study the behavior of concrete square columns strengthening with circulation technique. In Iraq, there are significantly more reinforced rectangular and square columns than reinforced circular columns in reinforced concrete buildings. Moreover, early research studies indicated that strengthening of rectangular or square columns using wraps of CFRP (Carbon Fiber Reinforced Polymer) provided rather little enhancement to their load-carrying capacity. In this paper, shape modification technique was performed to modify the shape (cross section) of the columns from square columns into circular colu

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Engineering
The Efficiency of Belled Piles in Multi-Layers Soils Subjected to Axial Compression and Pullout Loads: Review
...Show More Authors

Multi-belled piles are piles with enlarged ends; these piles have one or further bells at the lower third part of the pile. These piles are suitable for many soils with problems such as softening clay, the variation of groundwater table, expansive soils, black cotton soil, and loose sand. The current study reviewed the behavior of belled piles in multi-layer soils subjected to axial compression and pullout loading. The review covered the experimental and theoretical works on belled piles in multi-layered soils. These piles were subjected to static and dynamic loadings in compression and pullout cases. Most theoretical results focused on software such as PLAXIS 3D. The axial load applied on the piles comes from the upper

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sun Feb 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 12 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of Acute Flaccid Paralysis Surveillance System's Structure at Al-Russafa Health Directorate in Baghdad City
...Show More Authors

Objective: evaluation of Acute Flaccid Paralysis Surveillance (AFP) System's Structure at Al-Russafa Health directorate in Baghdad City. Methodology: descriptive study using evaluation approach conducted to measure the efficiency of AFP Surveillance System structure for period from November 27th 2014 to June 30th 2015. The study adopted the non-probability multi-stage sampling approach. As nineteen health facilities under surveillance are chosen and interview is conducted with a total of 50 health worker how are involved in the AFP Surveillance System. The data are gathered from sample by using question

... Show More
View Publication Preview PDF