Background: Differentiation between malignant and benign vertebral compression fracture is often problematic. This is precisely difficult in elderly who are predisposed to benign compression caused by osteoporosis .Establishing correct diagnosis is of great importance in determining the treatment andprognosis.A study was performed to determine which magnetic resonance imaging findings are useful in discrimination between metastatic and acute osteoporotic compression fractures of the spine. Recently MRI is being increasingly used for evaluation of these fractures.Objectives: The aim of this study is to establish the correct diagnosis of malignant and benign compression vertebral fracture by MRI to determine treatment and prognosis.Methods: MRI of (45 )patients with vertebral compression fracture who underwent MRI of spine during 2 years period ( 2004-2006) in Neuro surgical hospital were retrospectively reviewed by an expedient radiologist , A collapsed vertebra were considered to be acute if there was recent history of back pain of less than 3moths. All MRI sequences needed for spine examination was done( T1WI SE, T2WI GE STIR, and Mylography ) and Gadolinium contrast medium was given to all patients..Results: Of total 45 patients (31male, 14 female, their age range between 18-72years) , The criteria used to differentiate between benign andmalignant collapse spine on MRI was based on the signal intensity, morphology and contrast enhancement for the correct diagnosis. Homogenous and diffuse abnormal signal intensity, posterior convexity and involvement of pedicles are sign that are strongly suggestive of malignant collapse .Conversely, a band like area of low signal intensity adjacent to depressed end plateand preservation of signal intensity of vertebra suggest benign nature of the collapse.Conclusions: We found that MRI features is helpful in differentiation of malignant and benign compression fractures in majority of cases, and if initial MRI finding are equivocal correlation with other images technique, follow up and biopsy in selected cases helpful in arriving correct diagnosis
This study evaluates the performance of magnetic abrasive finishing (MAF) of aluminum alloy in terms of achieving materials removal (MR). A vertical milling machine is used to perform the finishing process using a developed MAF unit that consists of an inductor made out of a 150 mm long and 20 mm diameter iron core wound with 1500 turns and 0.5 mm copper wire. The commutator and magnetic pole are attached at the top and bottom of the inductor, respectively. The required current is supplied using a DC power supply. The South Pole workpiece is a 100×50×3 mm3 plate of AA 1100 aluminum alloy, whereas the magnetic pole represented the North Pole. Pole rotational speed, applied current, and abrasive finishing time was selected as
... Show MoreIntroduction: The association between acute stroke and
renal function is well known. The aim of this study is to
know which group of patients with acute stroke is more
likely to have undiagnosed Chronic Kidney Disease and
which risk factors are more likely to be associated with.
Methods:We studied 77 patients who were diagnosed to
have an acute stroke.Patients were selected between
April2011andJune 2011 using the " 4-variable
Modification of
Diet in Renal Disease Formula " which estimates
Glomerular Filtration Rate using four variables :serum
creatinine ,age ,race and gender.
Results :The study included 38 male and 39 females
patients ,aged (35-95) years. Glomerular Filtration Rate in
patients wi
Abstract: Narrow laser pulses have been essential sources in optical communication system. High data rate optical communication network system demands compressed laser source with unique optical property. In this work using pulsed duration (9) ns, peak power 1.2297mW, full width half maximum (FWHM) 286 pm, and wavelength center 1546.7 nm as compression laser source. Mach Zehnder interferometer (MZI) is built by considering two ways. First, polarization maintaining fiber (PMF) with 10 cm length is used to connect between laser source and fiber brag grating analysis (FBGA). Second, Nested Mach Zehnder interferometer (NMZI) was designed by using three PMFs with 10 cm length. These three Fibers are splicing to sing
... Show MoreA common approach to the color image compression was started by transform
the red, green, and blue or (RGB) color model to a desire color model, then applying
compression techniques, and finally retransform the results into RGB model In this
paper, a new color image compression method based on multilevel block truncation
coding (MBTC) and vector quantization is presented. By exploiting human visual
system response for color, bit allocation process is implemented to distribute the bits
for encoding in more effective away.
To improve the performance efficiency of vector quantization (VQ),
modifications have been implemented. To combines the simple computational and
edge preservation properties of MBTC with high c
Image compression is one of the data compression types applied to digital images in order to reduce their high cost for storage and/or transmission. Image compression algorithms may take the benefit of visual sensitivity and statistical properties of image data to deliver superior results in comparison with generic data compression schemes, which are used for other digital data. In the first approach, the input image is divided into blocks, each of which is 16 x 16, 32 x 32, or 64 x 64 pixels. The blocks are converted first into a string; then, encoded by using a lossless and dictionary-based algorithm known as arithmetic coding. The more occurrence of the pixels values is codded in few bits compare with pixel values of less occurre
... Show MoreIn this paper, we investigate the automatic recognition of emotion in text. We perform experiments with a new method of classification based on the PPM character-based text compression scheme. These experiments involve both coarse-grained classification (whether a text is emotional or not) and also fine-grained classification such as recognising Ekman’s six basic emotions (Anger, Disgust, Fear, Happiness, Sadness, Surprise). Experimental results with three datasets show that the new method significantly outperforms the traditional word-based text classification methods. The results show that the PPM compression based classification method is able to distinguish between emotional and nonemotional text with high accuracy, between texts invo
... Show MoreItem Difficulty and Item Discrimination Coefficient for School and College Ability Tests (SCAT) Advanced Form in Classical Test Theory (CTT) and Item Response Theory (IRT) and the Correlation among Them Mohammad moqasqas Haifa T. Albokai Assistant Professor of Measurement and Evaluation Associate Professor of Measurement and Evaluation College of Education, Taibah University The aim of this study was to study the item difficulty and item discrimination of the SCAT (advance form) with CTT, and IRT, and to study the correlation among them. To do this, the researchers used the data of their previous study, which conducted in (2011). It consisted of (3943) subject. Then, they used two-statistical programs (TAP, Bilog-MG-3) to obtain the item
... Show MoreMagnetic nanoparticles (MNPs) of iron oxide (Fe3O4) represent the most promising materials in many applications. MNPs have been synthesized by co-precipitation of ferric and ferrous ions in alkaline solution. Two methods of synthesis were conducted with different parameters, such as temperature (25 and 80 ̊C), adding a base to the reactants and the opposite process, and using nitrogen as an inert gas. The product of the first method (MNPs-1) and the second method (MNPs-2) were characterized by x-ray diffractometer (XRD), Zeta Potential, atomic force microscope (AFM) and scanning electron microscope (SEM). AFM results showed convergent particle size of (MNPs-1) and (MNPs-2) with (86.01) and (74.14)
... Show MoreAbstract
Magnetic abrasive finishing (MAF) process is one of non-traditional or advanced finishing methods which is suitable for different materials and produces high quality level of surface finish where it uses magnetic force as a machining pressure. A set of experimental tests was planned according to Taguchi orthogonal array (OA) L27 (36) with three levels and six input parameters. Experimental estimation and optimization of input parameters for MAF process for stainless steel type 316 plate work piece, six input parameters including amplitude of tooth pole, and number of cycle between teeth, current, cutting speed, working gap, and finishing time, were performed by design of experiment
... Show MoreAn experimental study was carried out to improve the surface roughness quality of the stainless steel 420 using magnetic abrasive finishing method (MAF). Four independent operation parameters were studied (working gap, coil current, feed rate, and table stroke), and their effects on the MAF process were introduced. A rotating coil electromagnet was designed and implemented to use with plane surfaces. The magnetic abrasive powder used was formed from 33%Fe and 67% Quartz of (250µm mesh size). The lubricant type SAE 20W was used as a binder for the powder contents. Taguchi method was used for designing the experiments and the optimal values of the selected parameters were found. An empirical equation representing the r
... Show More