Background: Differentiation between malignant and benign vertebral compression fracture is often problematic. This is precisely difficult in elderly who are predisposed to benign compression caused by osteoporosis .Establishing correct diagnosis is of great importance in determining the treatment andprognosis.A study was performed to determine which magnetic resonance imaging findings are useful in discrimination between metastatic and acute osteoporotic compression fractures of the spine. Recently MRI is being increasingly used for evaluation of these fractures.Objectives: The aim of this study is to establish the correct diagnosis of malignant and benign compression vertebral fracture by MRI to determine treatment and prognosis.Methods: MRI of (45 )patients with vertebral compression fracture who underwent MRI of spine during 2 years period ( 2004-2006) in Neuro surgical hospital were retrospectively reviewed by an expedient radiologist , A collapsed vertebra were considered to be acute if there was recent history of back pain of less than 3moths. All MRI sequences needed for spine examination was done( T1WI SE, T2WI GE STIR, and Mylography ) and Gadolinium contrast medium was given to all patients..Results: Of total 45 patients (31male, 14 female, their age range between 18-72years) , The criteria used to differentiate between benign andmalignant collapse spine on MRI was based on the signal intensity, morphology and contrast enhancement for the correct diagnosis. Homogenous and diffuse abnormal signal intensity, posterior convexity and involvement of pedicles are sign that are strongly suggestive of malignant collapse .Conversely, a band like area of low signal intensity adjacent to depressed end plateand preservation of signal intensity of vertebra suggest benign nature of the collapse.Conclusions: We found that MRI features is helpful in differentiation of malignant and benign compression fractures in majority of cases, and if initial MRI finding are equivocal correlation with other images technique, follow up and biopsy in selected cases helpful in arriving correct diagnosis
Background: Numerous methods have been described for achievement of Intermaxillary fixation in the treatment of fractures of facial skeleton. Conventional methods like Erich arch bars and eyelet wires are currently the most common methods for achieving intermaxillary fixation (IMF), however, they have their own disadvantages. Since 1989, IMF using intraoral self-tapping IMF screws has been introduced for treatment of mandibular fractures. The aim of this study was to evaluate the efficacy, advantages, disadvantages and potential complications associated with using of self-tapping IMF screws in the treatment of mandibular fractures. Material and Methods: Twenty patients with favorable mandibular fractures, attended to Oral and Maxillofacial
... Show MoreObjective: To evaluate the knowledge and practices of nursing staff at the orthopedic wards relative to
nursing care presented to patients with femur fractures.
MethodologyThe sample consisted of (50) staff nurses was selected out of orthopedic wards of five
teaching hospital in Baghdad city for duration 15th Nivember 2001-15th of January 2002.
For the purpose of data collection, two instruments were constructed. First, observational
checklist for the practices measurements and second, knowledge test for the evaluation of the nurse
knowledge. Such construction was employed through literature review and validity expert’s responses.
Data were analyzed through the application of descriptive data analysis (frequency, p
This work presents an experimental study of heat transfer and flow of distilled water and metal oxide nanofluid Fe3O4-distilled water at concentrations of (φ = 0.3, 0.6, 0.9 %) by volume in a horizontal pipe with constant magnetic field. All the tests are carried out with Reynolds number range (2900-9820) and uniform heat flux (11262-19562 W/m2). The results show that, the nanofluid concentration and magnetic intensity increase, the Nusselt number increases. The maximum enhancement in Nusselt number with magnetic nanofluid is (5.4 %, 26.4 %, 42.7 %) for volume concentration (0.3, 0.6, 0.9 %) respectively. The enhancement is maximized with magnetic intensity (0.1, 0.2, 0.3 tesla) respectively to (43.9, 44
... Show MoreImage compression is very important in reducing the costs of data storage transmission in relatively slow channels. Wavelet transform has received significant attention because their multiresolution decomposition that allows efficient image analysis. This paper attempts to give an understanding of the wavelet transform using two more popular examples for wavelet transform, Haar and Daubechies techniques, and make compression between their effects on the image compression.
Gravity and magnetic data are used to study the tectonic situation of Al-Kut- Al-
Hai and surrounding areas in central Iraq. The study included application of many
processing and interpretation programs. The window method with different spacing
was used to separate the residual from regional anomalies for gravity and magnetic
data. The Total Horizontal Derivative (THDR) techniques used to identify the fault
trends in the basement and sedimentary cover rocks depending upon gravity and
magnetic data. The identified faults in the study area show (NW-SE), (NE-SW) (NS)
and (E-W) trends. It is believed that these faults extending from the basement to
the upper most layer of the sedimentary cover rocks.
In this study, zinc ferrite magnetic nanoparticles (ZnFe2O4, ZFO MNPs) were employed as a sorbent for the removal of oil spill from water surfaces. ZFO MNPs were synthesized via a sol-gel process and characterized by Fourier transform infrared spectroscopy (FTIR) and X-ray powder diffraction (XRD). Both the apparent density and magnetic force were determined. ZFO MNPs presented a considerable magnetic force (40.22 mN) and an adequate density (0.5287 g/cm3), which are important for the magnetic separation and flotation. Four oil samples (gasoline engine oil, crude oil, used motor oil and diesel engine oil) were used to investigate the gravimetric oil removal capability of ZFO MNPs. The oil sorption capacit
... Show MoreBackground: Acute appendicitis is the most common surgical abdominal emergency with a life time prevalence of 1 to 7 individuals. Because the clinical diagnosis of acute appendicitis remains a challenge to surgeons, so different aids were introduced like different scoring systems, computer aided programs, ultrasonography, computerized tomography, Magnetic resonance imaging, Gastrointestinal tract contrast studies and laparoscopy to improve the diagnostic accuracy.
Objective: To evaluate ultrasound in the diagnosis of acute appendicitis in those patients clinically diagnosed with histopathology as gold standard.
Methods: A cross sectional study carried in Al-kindy Teaching
... Show More