Cesarean section, which was introduced into clinical practice as a lifesaving procedure for both the mother and the baby, is one of the most common surgeries performed in modern obstetrics. Formerly it was performed in interest of the mother; currently it is frequently done for fetal indication. As other procedures of some complexity, its use follows the health care inequity pattern of the world; underuse in low income setting, and adequate or even unnecessary use in middle and high income setting (1).
The first modern cesarean section was performed by German gynecologist Ferdinand Adolf Kehrer in 1881. Cesarean section is often performed when a vaginal delivery would put the baby's or mother's life or health at risk. Many are also performed upon request (2).
Pregnancy and delivery are considered a normal physiological state in women; however, of all deliveries approximately 10% are considered high risk, some of which may require Cesarean section (3).
The cesarean delivery rate has increased throughout the world. Cesarean rates have increased over the past 40 years from approximately 5% to more than 30% in many industrialized countries (4). The cesarean rate is approximately 21.1% for the most developed regions of the globe, 14.3% for the less developed regions, and 2% for the least developed regions (5).
Recent studies reaffirm earlier recommendations of the world health organization (WHO), about optimal C-section rates, addressing that the best outcomes of mothers and babies appear to occur with C-section rates of 5% to 10%, while rates above 15% seem to do more harm than good (6).
In US the cesarean rate increased dramatically during the 1970s and early 1980s this may be accredited to the improved technology in detecting pre-birth distress, and began to decline in the late 1980s (based on data from the National Hospital Discharge Survey). Between 1989 and 1996 the total cesarean rate decreased as a result of a decrease in the primary rate and an increase in the rate of vaginal birth after Cesarean (VBAC). Since 1996, these trends have reversed, and increases have been rapid and sustained for primary and repeat Cesareans over the past decade (7).
According to the Iraq Multiple Indicator Cluster Survey 2006 (Iraq MICS 2006) (8), about 20% of births were delivered by C-section (Table 1). Moreover, a brief and rapid survey of C-sections in Baghdad Teaching Hospital, a tertiary referral hospital, indicated that the emergency C-sections account only for 62.2% of the total number of C-sections performed outside the working hours during April 2010 (9).
Solar collectors, in general, are utilized to convert the solar energy into heat energy, where it is employed to generate electricity. The non-concentrating solar collector with a circular shape was adopted in the present study. Ambient air is heated under a translucent roof where buoyant air is drawn from outside periphery towards the collector center (tower base). The present study is aimed to predict and visualize the thermal-hydrodynamic behavior for airflow under inclined roof of the solar air collector, SAC. Three-dimensional of the SAC model using the re-normalization group, RNG, k−ε turbulence viscus model is simulated. The simulation was carried out by using ANSYS-FLUENT 14.5. The simulation
... Show MoreThe present study includs the isolation and identification of Keratinophilic fungi in fresh water samples collected from Tigris river in Baghdad, Iraq. Samples were collected from different districts of Baghdad (Al-Rustumia, Madina Al-Teb, Al-Azamia, Al-Kadimia, Al-Dorha and Al-Kanah). The water samples were examined for keratinophilic fungi by the plating method culturing and Hair Baiting Technique. A total number of 18 genera are recorded, in which the Tigris water indicates an impressive diversity of fungi. A variety of fungal strains were isolated from river water, out of 814 fungal colonies, Aspergillus terrus (5.5%) was the most frequent species, followed by Asperg
... Show MorePure Polyaniline salt, and protonation PANI by H2SO4 were synthesized by electro-chemical oxidative polymerization of aniline with acidity of H2SO4. The solution was prepared in reaction temperature equal 291 K and the acidity of aqueous solution was 1 molarities. The prepared polyaniline was characterized by FT-IR, the result indicate that the intensity is increase with increasing of applied voltage. The dc conductivity has been measured for bulk polyaniline pure and doped in the form of compressed pellet with evaporated Ohmic Al electrodes in temperature range (303-423) K. The Eav energy of the thermal rate process of the electrical conductivity was determined. The results indicate that the dc conductivity of doped samples are two or t
... Show MoreThis research Sought to Determine the Relationship and impact between the tax knowledge in dimensions of the tax compliance costs (monetary costs, time costs, psychic costs) Since the sample included 81 individuals represented by the Executive directors and Financial and Accountant working in the Joint-stock company, A questionnaire was used as a tool for data collection and its analysis. For the purpose of analyzing the research data the statistical package for social science, SPSS. The most important tools used in the statistical analysis are:(standard deviation, and simple linear regression, percentages, arithmetic mean, Cronbach's alpha, F-test, T- Test). The research found a weakness attenti
... Show MoreThis research aims at investigating pupils’ ability in using discourse markers which are identified in the English textbooks of secondary schools. Four texts are chosen from third intermediate class. The four texts are short stories of different topics.
This research hypothesizes that there are no statistical significant differences among Iraqi intermediate pupils’ ability in using textual
... Show MoreAn experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.
This research raised the strategic selection factors and dimensions of the quality of higher education and what the nature of their relationship and has been collecting a sample search from the technological University of president scientific departments and administrative and scientific associates and chiefs of branches This research aims at studying factors affecting the strategic selection effects these factors in the quality of higher education and the combination of these factors has been identified as a group of selected dimensions of quality of higher education and study link relationships and affecting factors and strategic selection of (risk, previous strategies, resources, time, considerations and internal trends) and d
... Show MoreThe present study is undertaken to evaluate the effects of hypothyroidism induced by carbimazol in male rat reproductive system. Rats were treated with carbimazol (80 and 160 mg/kg body weight) daily for two, four, six, and eight weeks, while control rats were given distilled water orally. The results of these experiments are: 1-Treatment with carbimazol produced increase in body weight of treated animals. This increase was not statistically significant even at high concentrations. 2-Decrease in testicular weight was observed during all administration points. This decrease was aggravated proportional to duration and dose (p≤0.001). 3-Results of most intervals showed significant decrease in epididymal-head weight, while no sig
... Show MoreThe Aim of this paper is to investigate numerically the simulation of ice melting in one and two dimension using the cell-centered finite volume method. The mathematical model is based on the heat conduction equation associated with a fixed grid, latent heat source approach. The fully implicit time scheme is selected to represent the time discretization. The ice conductivity is chosen
to be the value of the approximated conductivity at the interface between adjacent ice and water control volumes. The predicted temperature distribution, percentage melt fraction, interface location and its velocity is compared with those obtained from the exact analytical solution. A good agreement is obtained when comparing the numerical results of one