ABSTRACTBackground: In Medical ethics education, improving medical student’s attitudes toward respecting the right of patients is an essential task. The medical students’ attitude has been affected by social, educational and personality background factors.Objective: To investigate medical student’s attitudes regarding medical ethics courses.Method: The study was conducted in Al-Kindy College of Medicine on academic year (2013 -2014) for the period from January to September. A cross- sectional study design was adopted with a self- administered questionnaire form distributed to medical students in the 5th-6th under graduate grades. The questionnaire consisted of 31 items relevant to student’s opinion about attitudes concerning ethics courses.Result: Out of overall 113 students 90(78.1%) responded, the majority 88.9% considered medical ethics teaching for medical students an important issue, and 85.5% had general interest in learning more about medical ethics. However, about 84.4% agreed that medical ethics teaching would influence the attitudes and behaviors of doctors, and improvepatient doctor relationship, but about 65.6% of students were confident with their ability to recognize significant ethical problems in clinical practice. Only 46.7% knew how to proceed when a patient is mentally incompetent.Conclusion: Medical students have positive knowledge andattitude about the medical ethics teaching, but they may notbe adequately prepared to meet the challenges of clinicalpractice. There should be incorporation of creative andintegrated ethics curriculum to start in the first medical grade,with emphasis on ethical aspect of daily medical practice.
Diagnostic X-ray is one of the ionizing radiation that plays an important role in medical examination. Despite its great benefit, it is considered the largest source of artificial radiation exposure to public. The aim of the study is to measure the entrance surface dose (ESD) of patients undergoing chest, lumber spine and knee X-ray examination using TLD-100. The mean Entrance surface dose of chest (PA), lumber spine (AP, LAT) and knee (AP, LAT) are 1.3mGy, 8.57mGy, 21.5mGy and 0.49mGy, 0.48mGy respectively. The ESDs measured were found to be higher than the published work.
Thirty swabes of medical implants were collected from Al-Yarmouk's hospital which were cultured on manitole agar to isolate Staphelococcus aureus . Only four samples gave positive results with this media. It was used ten types of antibiotics to test the sensitivity of this bacterium against them. All isolates of S. aureus were recorded as multidrug resistant and were considered as MRSA. One pledge alternative therapy is the utilize of certain pure bacterocin MIC (32.5 to 62.5 μg/ml) and it was compared with vancomycin (200-400 μg/ml) with average of (8 – 15) mm diameter of inhibition zones recpectively. The first reduction of biofilm formation ability has been proved in catheters when treatedby pure bacterocin. The test shows the highes
... Show MoreThe purified prepared compounds were identified through different methods of identification i.e, I.R, UV-vi^ble-spectroscopy in addition to (coloured tests) Calculation of the sum of OH groups. TLC techniques were also used to test the purity and the speed ofthe rate of flow (RF).
Security concerns in the transfer of medical images have drawn a lot of attention to the topic of medical picture encryption as of late. Furthermore, recent events have brought attention to the fact that medical photographs are constantly being produced and circulated online, necessitating safeguards against their inappropriate use. To improve the design of the AES algorithm standard for medical picture encryption, this research presents several new criteria. It was created so that needs for higher levels of safety and higher levels of performance could be met. First, the pixels in the image are diffused to randomly mix them up and disperse them all over the screen. Rather than using rounds, the suggested technique utilizes a cascad
... Show MorePurpose: To contribute to the development of an appropriate program for the management of medical waste based on clear-cut principles in order to reach the overall goal of improving the public health and environment of the population in our country.
Design / Approach / Introduction: The research is based on the analytical descriptive approach as a method of study in the field of data collection using a check list and analysis of the data through the use of some statistical treatments.
Results: The need is to establish a medical waste management in hospitals and follow international standards in all stages of waste management from sorting, collection, transportation and treat
... Show Moreم.د. فاطمة حميد ،أ.م.د وفاء صباح محمد الخفاجي, International Journal of Psychosocial Rehabilitation,, 2020 - Cited by 1
Background: Toxin-producing Shiga Escherichia coli has been identified as a new foodborne pathogen that poses a significant health risk to humans. Shiga toxin-producing Escherichia coli can be found in raw cow milk and its derivatives. A small number of Escherichia coli strains that produce shiga toxin are pathogenic. Aim of study: The study aimed to see if there were any virulence genes in 50 milk samples that were typical of Entero-haemorrhagic E. coli and evaluate the Myrtus communis effects on these bacteria. Materials and Method: Milk samples were used to isolate E. coli bacteria (n= 27), biochemically analyzed, and genetically screened for virulence genes using a multiplex (PCR). The hydro-alcoholic extraction of Myrtus communis leave
... Show MoreBacteriological characteristics of Tigris river water were assessed monthly to monitor the impact of pollutants of Medical City waste water for the period from January to June-2013. Four stations were selected for the study, the first station placed before the Medical City Complex (500 meters). The second station represent Medical City sewage discharge into the river, where represents the study area. The third station placed (500 meters) after the second station, and the forth station is located on (2000 meters) after the second station.
Samples collected monthly to monitor the changes of water indicators showed that: Total Bacterial Count (10000 to 2700000 cells/1 ml), Total Coliform (200-3700 cells/100 ml), Fecal Coliform (100-2400