ABSTRACTBackground: In Medical ethics education, improving medical student’s attitudes toward respecting the right of patients is an essential task. The medical students’ attitude has been affected by social, educational and personality background factors.Objective: To investigate medical student’s attitudes regarding medical ethics courses.Method: The study was conducted in Al-Kindy College of Medicine on academic year (2013 -2014) for the period from January to September. A cross- sectional study design was adopted with a self- administered questionnaire form distributed to medical students in the 5th-6th under graduate grades. The questionnaire consisted of 31 items relevant to student’s opinion about attitudes concerning ethics courses.Result: Out of overall 113 students 90(78.1%) responded, the majority 88.9% considered medical ethics teaching for medical students an important issue, and 85.5% had general interest in learning more about medical ethics. However, about 84.4% agreed that medical ethics teaching would influence the attitudes and behaviors of doctors, and improvepatient doctor relationship, but about 65.6% of students were confident with their ability to recognize significant ethical problems in clinical practice. Only 46.7% knew how to proceed when a patient is mentally incompetent.Conclusion: Medical students have positive knowledge andattitude about the medical ethics teaching, but they may notbe adequately prepared to meet the challenges of clinicalpractice. There should be incorporation of creative andintegrated ethics curriculum to start in the first medical grade,with emphasis on ethical aspect of daily medical practice.
Chlorine disinfection is a globally used method to ensure the safety of drinking water. However, it has not always been successful against viruses and, therefore, it is important to find new methods to disinfect water. Seventeen different coliphages were isolated from the treated municipal wastewater. These coliphages and MS2 were treated with different dosages of chlorine in drinking water, and a combined chlorine/ultraviolet irradiation treatment for the chlorine-resistant coliphages. Chlorine disinfection with 0.3–0.5 mg/L total chlorine (free Cl-dosage 0.12–0.21 mg/L) for 10 min achieved 2.5–5.7 Log10-reductions for 11 sensitive coliphages. The six most resistant coliphages showed no reduction with these chlorine concentra
... Show MoreAirlift reactors are widely used in the chemical and biochemical applications as effective contactors for mass and heat transfer. The main advantages of airlift contactor compared with simple bubble column are ease of construction, low shear rate, high capacity, good mixing and liquid circulation without mechanical agitators and circulating pumps.
In this work, growth characteristics of Chlorella vulgaris microalgae were studied in an internal loop airlift photobioreactor for biomass production. The bioreactor operated under batch and semi-continuous culture mode using commercially available 20:20:20+TE NPK fertilizer as nutrients. The experiments were conducted to evaluate the growth rate and biomass productivity of
... Show MoreObjective: The current investigation focused on Acinetobacter baumannii (A. baumanni), due to its growing significance as a hospital infection-causing pathogen and its resistance to several medications.Material and Method: Sixty-five isolates of A. baumannii were isolated from wound samples of patients admitted to different hospitals in Baghdad between January and April of 2023. Two types of methods were used in the detection of biofilm formation: the first one was Congo red agar method and the second one was microtiter plate method. Genotypic detection of various virulence factors associated with A. baumannii was performed using monoplex, multiplex, and ERIC-PCR.Result and Discussion: To use the PCR method to examine
... Show MoreThis paper reports an experimental study regarding the influence of vertical oscillations on the natural convection heat transfer from a vertical channel. An experimental set-up was constructed and calibrated; the vertical channel was tested in atmosphere at 25o
C. The channel-to-ambient temperature difference was varied with the power supply to the electrical heater ranging between
15W to 70W divided into five levels. Data sets were measured under different operating condition from a test rig under six vibrating velocities (VVs) levels ranging from (5-30 m/s) in addition to the stationary state. The results show that the maximum heat transfer enhancement factor (E) occurs at Rayleigh number (Ra=2.328×103 ) and vibrational Reynol
In this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel
... Show More