Preferred Language
Articles
/
jkmc-460
Unstable Angina /Non ST Elevation Myocardial Infarction: Frequency of Conventional Risk Factors; TIMI Risk Score, and Their Impact On Angiographic Data
...Show More Authors

Background: Appreciation of the crucial role of risk factors in the development of coronary artery disease (CAD) is one of the most significant advances in the understanding of this important disease. Extensive epidemiological research has established cigarette smoking, diabetes, hyperlipidemia, and hypertension as independent risk factors for CADObjective: To determine the prevalence of the 4 conventional risk factors(cigarette smoking, diabetes, hyperlipidemia, and hypertension) among patients with CAD and to determine the correlation of Thrombolysis in Myocardial Infarction (TIMI) risk score with the extent of coronary artery disease (CAD) in patients with unstable angina /non ST elevation myocardial infarction (UA/NSTEMI).Methods: We conducted a descriptive study among 100 patients admitted with UA/NSTEMI to three major cardiac centers in Iraq: Iraqi Centre for Heart Disease ,Ibn- Al-Bitar Hospital for cardiac surgery and Al -Nasyria Cardiac Centre from January 2010 to January 2o11.Frequency of each conventional risk factors and number of conventional risk factors present among patients with CAD, compared between men and women and by age are estimated at study entry. The TIMI risk score was stratified on seven standard variables. The extent of CAD was evaluated on angiography and significant CAD was defined as ≥ 70% stenosis in any one of the three major epicardial vessels and ≥50% in LMS.Results : Among 100 patients with UA/NSTEMI , 82% of patients have one or more risk factors and only 18%of patients lacked any of 4 conventional risk factors.Smoking is the most common risk factor in male patients while diabetes mellitus and dyslipidemia are common among female patients, and all these results are statistically significant.There were 64 % patients with TIMI score < 4 (low and intermediate TIMI risk score) and 36% patients with TIMI score >4 (high TIMI risk score). Patients with TIMI score > 4 were more likely to have significant three vessel CAD and LMS versus those with TIMI risk score < 4 who have less severe disease (single and two vessel disease).Conclusion: Antecedent major CAD risk factor exposures were very common among those who developed CAD emphasizing the importance of considering all major riskfactors in determining CAD risk estimation . Patients with a high TIMI risk score were more likely to have severe multivessel CAD compared with those with low or intermediate TIMI risk score. Hence, patients with TIMI score >4 should be referred for early invasive coronary evaluation to derive clinical benefit.Key words: unstable angina , Thrombolysis in Myocardial Infarction score, risk factors

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 01 2009
Journal Name
Iraqi Journal Of Physics
Preparation Cadmium Telluride Compound and Study Structural Properties of thermal evaporation thin films
...Show More Authors

Polycrystalline ingots of cadmium telluride have been synthesized using the direct
reaction technique, by fusing initial component consisting from pure elements in
stoichiometric ratio inside quartz ampoule is evacuated 10-6 torr cadmium telluride has
been grown under temperature at (1070) oC for (16) hr. was used in this study, the phases
observed in growing CdTe compound depend on the temperature used during the growth
process. Crystallography studies to CdTe compound was determined by X-ray diffraction
technique, which it has zinc blend structure and cubic unit cell, which lattice constants is
a=6.478
oA

View Publication Preview PDF
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Prediction of Effective Bed Thermal Conductivity and Heat Transfer Coefficient in Fluidized Beds
...Show More Authors

Experimental study of heat transfer coefficients in air-liquid-solid fluidized beds were carried out by measuring the heat rate and the overall temperature differences across the heater at different operating conditions. The experiments were carried out in Q.V.F. glass column of 0.22 m inside diameter and 2.25 m height with an axially mounted cylindrical heater of 0.0367 m diameter and 0.5 m height. The fluidizing media were water as a continuous phase and air as a dispersed phase. Low density (Ploymethyl-methacrylate, 3.17 mm size) and high density (Glass beads, 2.31 mm size) particles were used as solid phase. The bed temperature profiles were measured axially and radially in the bed for different positions. Thermocouples were connecte

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 28 2017
Journal Name
Iraqi Journal Of Science
Morphological and Optical Properties of CdS Quantum Dots Synthesized with different pH values
...Show More Authors

View Publication
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Advances In Science And Technology Research Journal
Experimental Investigation and Fuzzy Based Prediction of Titanium Alloy Performance During Drilling Process
...Show More Authors

View Publication
Scopus (9)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Estimation of Some Mechanical Soil Properties from Static and Dynamic Plate Load Tests
...Show More Authors

When the depth of stressed soil is rather small, Plate Load Test (PLT) becomes the most efficient test to estimate the soil properties for design purposes. Among these properties, modulus of subgrade reaction is the most important one that usually employed in roads and concrete pavement design. Two methods are available to perform PLT: static and dynamic methods. Static PLT is usually adopted due to its simplicity and time saving to be performs in comparison with cyclic (dynamic) method. The two methods are described in ASTM standard.

In this paper the effect of the test method used in PLT in estimation of some mechanical soil properties was distinguished via a series of both test methods applied in a same site. The comparison of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Advanced Veterinary And Animal Research
Histological and histochemical characteristics of the esophagus in local breed donkey (Equus asinus)
...Show More Authors

Objective: Certain advantages of donkeys are still not listed as for other equine species. Moreover, donkeys lack comprehensive scientific studies. The present study examines the histological architecture and histochemical characteristics of the esophagus in the Iraqi local breed donkey (Equus asinus). Materials and Methods: Eight esophagus samples were collected from a local breed donkey. Tissue specimens (~1 cm³) were collected from the cervical, thoracic, and abdominal regions of the esoph¬agus and processed via routine histological technique. The tissue sections were stained with hema¬toxylin and eosin, Massons Trichrome, and combined Alcian blue (pH 2.5) plus PAS (AB-PAS). Results: The esophagus of the local breed donkey h

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Sep 14 2022
Journal Name
Lecture Notes In Civil Engineering
Effect of Nozzle Condition and Type in the Spray Quality in Wheat Plants
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jun 05 2011
Journal Name
Baghdad Science Journal
Synthesis, spectroscopic and biological studies of some metal complexes with orthoamino hydrazo benzene
...Show More Authors

Ortho amino hydrazobenzene (L) has been prepared from the reaction of ortho amino phenyl thiol with phenyl hyrazan in mole ratio(1:1). It has been characterized by elemental analysis (C, H, N), IR, UV–Vis. The complexes of the bivalent ions (Co, Ni, Cu, Zn, Pd, Cd, Hg and Pb) and the trivalent (Cr) have been prepared and characterized too. The structural have been established by elemental analysis(C,H,N), IR , UV – Vis spectra , conductivity measurements , atomic absorption and magnetic susceptibility . The complexes showed characteristic behaviour of octahedral geometry around the metal ion and the( N,N) ligand coordinated in bidentate modeexcept with pd showed square planer. ? ,kf , ?max for the complexes were estimated too .

... Show More
View Publication
Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Multidisciplinary Engineering Science And Technology (jmest)
Fabrication And Characterization Of P-Cuo/N-Si Heterojunction For Solar Cell Applications
...Show More Authors

This studies p- CuO / n - Si hete-rojunction was deposited by high vacuum thermal evaporation of Copper subjected to thermal oxidation at 300 oC on silicon. Surface morphology properties of The optical properties concerning the transmission spectra were studies for prepared thin films. this structure have been studied. XRD anaylsis discover that the peak at (𝟏𝟏𝟏-) and (111) plane are take over for the crystal quality of the CuO films. The band gap of CuO films is found to be 1.54 eV. The average grain size of is measured from AFM analysis is around 14.70 nm. The responsivity photodetector after deposited CuO appear increasing in response

Publication Date
Mon Mar 01 2021
Journal Name
Iraqi Journal Of Physics
Antibacterial and morphological properties of polypyrrole/silver nanocomposites synthesized by chemical oxidative polymerization
...Show More Authors

Polypyrrole/silver (PPy/Ag) nanocomposites was synthesized via a chemical oxidative method. The AFM analysis is performed to study the surface roughness, morphology and size distribution of the PPy particles and PPy-ag nanocomposites. The results indicated that as the concentration of Ag in the nanocomposite increases, the roughness also increases. The size of nanoparticles was also evaluated and found in the range of 15 nm to 125 nm. The PPy/Ag nanocomposites exhibited an effectiveness against Gram-negative Escherichia coli showing an inhibition zone of 4mm and displayed poor efficacy against Gram-positive Staphylococcus aureus. Based on given adequate antibacterial characteristics of PPy/Ag nanocomposites, it can be identified as

... Show More
Crossref (3)
Crossref