Preferred Language
Articles
/
jkmc-453
Ultrasound assessment of normal splenic length and spleen to left kidney ratio in sample of Iraqi population
...Show More Authors

Background: Spleen is a hemopoietic organ which is capable of supporting elements of different systems. It is affected by several groups of diseases; inflammatory, hematopoietic, reticuloendothelial proliferation, portal hypertension and storage diseases. Ultrasound (US) may detect mild splenomegaly before it is clinically palpable. Knowledge of the normal range of spleen size in the population being examined is a prerequisite. Racial differences in splenic length could result in incorrect interpretation of splenic measurements and such differences would make it difficult to standardize expected splenic length and to determine non- palpable splenic enlargement.Objectives: To measure the normal values of splenic lengthin Iraqi subjects and compare the results with western,Chinese and Jordanian data; to determine whether there is aconstant ratio of the length of the spleen to the left kidney,which could be used to diagnose splenomegaly withoutreference to a nomogram.Methods: This is a cross-sectional study conducted among a total of 280 subjects ranging in age from birth to 20 years (159 males and 121 females). US was used to measure maximum splenic and left kidney lengths to obtain normal values for splenic length and to determine spleen to left kidney ratio. The subjects were divided into the same age groups as those used by other similar international studies in order that comparisons with their results could be made.Results: Splenic lengths in Iraqi subjects are similar to those in American, Chinese and Jordanian subjects up to the age of 15 years. The spleen to left kidney ratio is strikingly constant with a mean value of 1. Using 2 SD above the mean as a guide, the upper limit of normal for spleen to left kidney ratio is 1.25.Conclusion: Splenomegaly should be suspected in children if the spleen is more than 1.25 times longer than the adjacent kidney.Key words: Spleen, subjects, ultrasound

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 15 2021
Journal Name
Al-academy
The Relations Of Design And The Role Of It Making The Idea For Fashion Design
...Show More Authors

Crossref
Publication Date
Tue Aug 03 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Impact of Audit Committees and Audit Quality on Timeliness of issuing annual Financial Report
...Show More Authors

The aim of this study is to get practical evidence from the Egyptian business environment The Impact of Audit Committees Effectiveness and External Audit Quality on Timeliness of annual Financial Report. Design and methodology: The study based on the content analysis technique to examine the annual reports of a sample of (30) companies listed on the Egyptian Stock Exchange (EGX100) during the period (2016-2019) with a total of (120) respondents. To test the research hypotheses, the results of the study indicate that there is a negative significant impact of audit committees on timeliness of annual financial report. Moreover, while there is a negative impact on the quality of the external audit on the timing of issuing the annual

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Synthesis and Characterization of Multishapes of Fe3O4 Nanoparticle by Solve-Hydrothermal Method Using Microwave Radiation
...Show More Authors

Iron oxide(Fe3O4) nanoparticles of different sizes and shapes were synthesized by solve-hydrothermal reaction assisted by microwave irradiation using ferrous ammonium sulfate as a metal precursor, oleic acid as dispersing agent, ethanol as reducing agent and NaOH as precipitating agent at pH=12. The synthesized Fe3O4 nano particles were characterized by X-ray diffraction (XRD), FTIR and thermal analysis TG-DTG. Sizes and shapes of Fe3O4 nanoparticles were characterized by Scanning Electron Microscopy (SEM), and atomic force microscopy (AFM).

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
A Comparative Evaluation of Gutta-Percha and Sealer Removal of Rotary Niti File Retreatment Systems
...Show More Authors

Forty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Oct 27 2023
Journal Name
Mathematical Modelling Of Engineering Problems
Impacts of Varied Injection Timing on Emission Levels, Combustion Efficiency, and Performance of Biodiesel Engines
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 27 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Internal audit of spending units and its impact on the efficiency of the federal budget
...Show More Authors

The role of internal control is based on the effectiveness of the budget through an analysis of the reality of the budget in the research sample as it was studied in the preparation and preparation stages and the implementation stage. The sample showed that the sample did not comply with what is stated in the Ministry of Finance publication of instructions and ceilings. In the process of preparing and resulting from the occurrence of deviations in large proportions both in the discussion of the Ministry of Finance or when implementation as a low rate of implementation and the absence of allocations for some items, although there is a need for them as well as the transfer of large proportions of transfers both up or down and the purpose o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 04 2025
Journal Name
European Journal Of Dentistry
The Effectiveness of Conventional and Advanced Aligning Archwires: The Insights of Two Randomized Clinical Trials
...Show More Authors
Abstract<p> Objectives This study aimed to compare the clinical effectiveness of four aligning archwires: Superelastic Nickel-Titanium (Superelastic-NiTi), SmartArch, Copper-Nickel-Titanium (Cu-NiTi), and Speed Tubular coaxial-Nickel-Titanium (Tubular coaxial-NiTi), regarding the alignment efficiency, associated perception of pain, and possibility of inducing root resorption.</p><p> Materials and Methods This study includes two randomized clinical trials run in parallel. Patients with 5 to 9 mm of mandibular anterior teeth crowding according to Little's irregularity index (LII) who needed fixed orthodontic appliances without extraction were randomly assigned to four groups of</p> ... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Apr 03 2016
Journal Name
Al-mustansiriyah Journal Of Science
Synthesis and Characterization of Some New Metal Complexes of Ligand [N-(3-acetylphenylcarbamothioyl)-4-chlorobenzamide]
...Show More Authors

A new ligand [N-(3-acetylphenylcarbamothioyl)-4-chlorobenzamide] (CAD) was synthesized by reaction of 4-Chlorobenzoyl isothiocyanate with 3-amino acetophenone, The ligand was characterized by elemental micro analysis C.H.N. S., FT-IR, UV-Vis and 1H,13C- NMR spectra, some transition metals complexes of this ligand were prepared and characterized by FT-IR, UV-Vis spectra, conductivity measurements, magnetic susceptibility and atomic absorption, From obtained results the molecular formula of all prepared complexes were [M(CAD)2(H2O)2]Cl2 (M+2 =Mn, Co, Ni, Cu, Zn, Cd and Hg),the proposed geometrical structure for all complexes were octahedral

Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
The effect of current density on the structures and photoluminescence of n-type porous silicon
...Show More Authors

Porous silicon (PS) layers were formed on n-type silicon (Si) wafers using Photo- electrochemical Etching technique (PEC) was used to produce porous silicon for n-type with orientation of (111). The effects of current density were investigated at: (10, 20, 30, 40, and50) mA/cm2 with etching time: 10min. X-ray diffraction studies showed distinct variations between the fresh silicon surface and the synthesized porous silicon. The maximum crystal size of Porous Silicon is (33.9nm) and minimum is (2.6nm) The Atomic force microscopy (AFM) analysis and Field Emission Scanning Electron Microscope (FESEM) were used to study the morphology of porous silicon layer. AFM results showed that root mean square (RMS) of roughness and the grain size of p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 31 2019
Journal Name
Journal Of Engineering And Applied Sciences
Preparation and Study Some of Properties of Unsaturated Polyester/Soda Lime Glass-Sawdust Hybrid Composite
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref