Preferred Language
Articles
/
jkmc-447
Effectiveness and safety of non-fixation method in cochlear implantation
...Show More Authors

ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear implantation.Methods: a prospective study carried out from September 2009 to September 2012 in Gazi Hariri Hospital. Eighty patients with congenital severe –profound sensorineural hearing loss prepared for cochlear implantation involved in the study and divided into 2 groups. Group A includes 40 patients in whom the internal device was fixed to the skull by nylon suture materials through small burr holes on both sides of the well. Group B includes 40 patients in whom the internal device placed in a tight sub pericranial pocket without nylon fixation to the skull. All patients followed postoperatively for 6 months observing wound healing and local complications (hematoma, infection, wound dehiscence, device extrusion and migration).Results: mean age 4.2 years and male-female ratio was 1.3:1.Group A: 1 patient (2.5%) developed minor wound infection treated conservatively. Three patients (7.5%) developedsevere wound infection with wound breakdown and device extrusion despite the use of antibiotics and local rotational flaps, the device was explanted in those 3 patients. Two patients (5%) developed hematoma without history of trauma and treated conservatively. One patient (2.5%) had device migration without affection of its function.Group B: 2 patients developed minor wound infection treated conservatively. One patient (2.5%) had severe wound infection ends up with wound dehiscence and device extrusion despite the use of antibiotics and local rotational flaps. Explantation of the device was done for this patient. Hematoma occurred in one patient (2.5%) without history of trauma and treated conservatively. Another one patient (2.5%) developed device migration without impairment of its function.Conclusion: creation of sub pericranial pocket without internal device fixation by nylon materials is an effective and reliable method in cochlear implantation without compromising the patient safety or device performance.Key words: cochlear implantation, non- fixation, sub pericranial pocket

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
International Journal Of Pharmaceutical Research
Sensitive Spectrophotometric Determination of Doxycycline in Pure and Dosage Forms using p-Bromanil
...Show More Authors

View Publication
Publication Date
Mon Oct 31 2022
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
The adoption of green management in Iraqi construction industry: The challenges and benefits
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
One and Two-Dimensional Hydraulic Simulation of a Reach in Al-Gharraf River
...Show More Authors

       

One and two-dimensional hydraulic models simulations are important to specify the hydraulic characteristics of unsteady flow in Al-Gharraf River in order to define the locations that facing problems and suggesting the necessary treatments. The reach in the present study is 58200m long and lies between Kut and Hai Cities. Both numerical models were simulated using HEC-RAS software, 5.0.4, with flow rates ranging from 100 to 350 m3/s. Multi-scenarios of gates openings of Hai Regulator were applied. While the openings of Al-Gharraf Head Regulator were ranged between 60cm to fully opened. The suitable manning roughness for the unsteady state was

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Evaluation of some Biochemical and Hematological Parameters in Patients with Chronic Kidney Disease
...Show More Authors

Background: Chronic kidney disease is a condition that results from an indefinite change in the structure and function of the kidneys. A slow, steady progression characterizes it and is irreversible.  Objectives: This study aims to evaluate the findings of certain biochemical and hematological tests in samples from Iraqi CKD patients.  Methods: This study included 90 subjects, where 70 patients with chronic kidney disease and 20 healthy individuals. Blood samples were collected from the patients during their visits to Ghazi Al-Hariri Surgical Specialties' Hospital- Medical City, Baghdad, Iraq. Age, sex and body mass index were assessed for each participant followed by renal function tests [serum blood urea, creatinine, uric acid a

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Materials Chemistry And Physics
Investigation of silica polymorphs stratified in siliceous geode using FTIR and XRD methods
...Show More Authors

View Publication
Crossref (63)
Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Engineering, Technology And Applied Science Research
Efficiency Assessment of a Signalized Roundabout and a Traffic Intersection in Baghdad City
...Show More Authors

In Baghdad city, Iraq, the traffic volumes have rapidly grown during the last 15 years. Road networks need to reevaluate and decide if they are operating properly or not regarding the increase in the number of vehicles. Al-Jadriyah intersection (a four-leg signalized intersection) and Kamal Junblat Square (a multi-lane roundabout), which are two important intersections in Baghdad city with high traffic volumes, were selected to be reevaluated by the SIDRA package in this research. Traffic volume and vehicle movement data were abstracted from videotapes by the Smart Traffic Analyzer (STA) Software. The performance measures include delay and LOS. The analysis results by SIDRA Intersection 8.0.1 show that the performance of the roundab

... Show More
Scopus (8)
Crossref (8)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Communications In Mathematical Biology And Neuroscience
The contribution of amensalism and parasitism in the three-species ecological system's dynamic
...Show More Authors

View Publication
Scopus (9)
Scopus Clarivate Crossref
Publication Date
Fri Jun 29 2018
Journal Name
Journal Of Engineering
Examining the Values and Principles of Agile Construction Management in Iraqi Construction Projects
...Show More Authors

The avoidance of failure in construction projects is not an easy task, which makes the failure of the construction project to achieve its objectives a major problem experienced by all countries in the world, especially Iraq. Where nearly two-thirds of the construction projects in the world have been suffered by significant problems as an increase in the cost of the project, delay in the specified duration for execution, and stopping the project. Therefore it is required to study and apply new methods for managing the construction project to ensure its success and achieve its objectives. The aim of this study is to study the Agile project management method and its impact on the construction project. In addition, to identi

... Show More
View Publication Preview PDF
Crossref (17)
Crossref
Publication Date
Wed Mar 08 2023
Journal Name
Sensors
A Critical Review of Remote Sensing Approaches and Deep Learning Techniques in Archaeology
...Show More Authors

To date, comprehensive reviews and discussions of the strengths and limitations of Remote Sensing (RS) standalone and combination approaches, and Deep Learning (DL)-based RS datasets in archaeology have been limited. The objective of this paper is, therefore, to review and critically discuss existing studies that have applied these advanced approaches in archaeology, with a specific focus on digital preservation and object detection. RS standalone approaches including range-based and image-based modelling (e.g., laser scanning and SfM photogrammetry) have several disadvantages in terms of spatial resolution, penetrations, textures, colours, and accuracy. These limitations have led some archaeological studies to fuse/integrate multip

... Show More
View Publication
Scopus (20)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Mon Dec 01 2025
Journal Name
Research Journal Of Chemistry And Environment
HPLC and Atomic Absorption Spectrometry for the Analysis of Pharmacological Activities in Soursop
...Show More Authors

Soursop is useful in treating diseases and the bioactive components of the fruit are beneficial in the treatment of gastrointestinal parasites. Annona muricata contains flavonoids, phenolic acids, and tannins in its leaves, pulp, and seeds. The current study provided an accurate analytical method for the pharmacologically active components, including glutathione, potassium, and vitamin B6, in soursop fruit samples of soursop using high-performance liquid chromatography and atomic absorption spectrometry. The fruits of the soursop were cleaned, peeled, and sliced into tiny pieces. The juice was chilled and kept in glass bottles. After blending the fruits with distilled water, they were placed on a magnetic stirrer and left for 72 hours. For

... Show More