ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear implantation.Methods: a prospective study carried out from September 2009 to September 2012 in Gazi Hariri Hospital. Eighty patients with congenital severe –profound sensorineural hearing loss prepared for cochlear implantation involved in the study and divided into 2 groups. Group A includes 40 patients in whom the internal device was fixed to the skull by nylon suture materials through small burr holes on both sides of the well. Group B includes 40 patients in whom the internal device placed in a tight sub pericranial pocket without nylon fixation to the skull. All patients followed postoperatively for 6 months observing wound healing and local complications (hematoma, infection, wound dehiscence, device extrusion and migration).Results: mean age 4.2 years and male-female ratio was 1.3:1.Group A: 1 patient (2.5%) developed minor wound infection treated conservatively. Three patients (7.5%) developedsevere wound infection with wound breakdown and device extrusion despite the use of antibiotics and local rotational flaps, the device was explanted in those 3 patients. Two patients (5%) developed hematoma without history of trauma and treated conservatively. One patient (2.5%) had device migration without affection of its function.Group B: 2 patients developed minor wound infection treated conservatively. One patient (2.5%) had severe wound infection ends up with wound dehiscence and device extrusion despite the use of antibiotics and local rotational flaps. Explantation of the device was done for this patient. Hematoma occurred in one patient (2.5%) without history of trauma and treated conservatively. Another one patient (2.5%) developed device migration without impairment of its function.Conclusion: creation of sub pericranial pocket without internal device fixation by nylon materials is an effective and reliable method in cochlear implantation without compromising the patient safety or device performance.Key words: cochlear implantation, non- fixation, sub pericranial pocket
Virtual reality, VR, offers many benefits to technical education, including the delivery of information through multiple active channels, the addressing of different learning styles, and experiential-based learning. This paper presents work performed by the authors to apply VR to engineering education, in three broad project areas: virtual robotic learning, virtual mechatronics laboratory, and a virtual manufacturing platform. The first area provides guided exploration of domains otherwise inaccessible, such as the robotic cell components, robotic kinematics and work envelope. The second promotes mechatronics learning and guidance for new mechatronics engineers when dealing with robots in a safe and interactive manner. And the thir
... Show MoreBackground:sThe aims of this study were to evaluate and compare the ability of three different techniques to obdurate simulated lateral canals, evaluate the effect of the main canal curvature on obturation of lateral canals and compare the gutta-percha penetration between coronal and apical lateral canals. Materials and methods: Resin blocks with 30 straight and 30 curved were used in this study. Each canal has two parallel lateral canals. The main canal has 0.3 mm apical diameter and 0.04 taper. The canals were divided into six groups according to canal curvature and obturation techniques used (n=10): Groups C1 and C2: straight and curved canals obturated with continuous wave technique using E&Q masterTM system. Groups O1 and O2: straight
... Show MoreThe measurements and tests of the samples conducted in the laboratories of the College of Agriculture included isolating bio-fertilizers and testing the efficiency of isolates that fix atmospheric nitrogen and solubilize phosphorous compounds. Bacteria were isolated and identified from the rhizosphere soils of different plants collected from various agricultural areas. A total of 74 bacterial isolates were obtained based on the phenotypic characteristics of the developing colonies, as well as biochemical and microscopic traits. The results of isolation and identification showed that among the 74 bacterial isolates, there were 15 isolates of A. chroococcum, 13 of Az. lipoferum, 13 of B. megaterium, 10 of P. putida, 10 of Actinomycetes, and n
... Show MoreThe aim of this study is to show the concepts of nuclear shape and the geometrical picture to the even-even nuclei of 164,166,168E isotopes in the context of the Interacting boson Model IBM-1. The energy spectra were calculated and the effective charge values (eB) of the electromagnetic transition strength were obtained and used to calculate the B(E2) values of the electromagnetic transitions and the quadrupole moment Q of 2+ -states. The Hamiltonian parameters were calculated by taking in account the properties of these nuclei. Comparison were made with the available experimental data and included in tables. The geometrical picture of these nuclei were looked at by calculating the deformation which were represented by the potentia
... Show MoreThe present work aimed to make a comparative investigation between three different ionospheric models: IRI-2020, ASAPS and VOACAP. The purpose of the comparative study is to investigate the compatibility of predicting the Maximum Usable Frequency parameter (MUF) over mid-latitude region during the severe geomagnetic storm on 17 March 2015. Three stations distributed in the mid-latitudes were selected for study; these are (Athens (23.50o E, 38.00o N), Jeju (124.53o E, 33.6o N) and Pt. Arguello (239.50o W, 34.80o N). The daily MUF outcomes were calculated using the tested models for the three adopted sites, for a span of five-day (the day of the event and two days preceding and following the event day). The calculated datasets were co
... Show MoreThe current research aims to investigate the skills of the intended meaning beyond the context when reading poetry among fifth literary students. To achieve the aim of the research, the researcher has followed the descriptive approach and used two tools: an open questionnaire that includes an inquiry about the skills of the intended meaning beyond the poetic context, and a closed questionnaire that were examined by the juries, and modified accordingly. Besides, its validity and stability were examined by applying the study on an exploratory sample of (15) teachers to reach its final version and determine the time required to answer it. Then, the researcher applied it on the research sample of (9
... Show More